메뉴 건너뛰기




Volumn , Issue , 2011, Pages 785-788

A methodology to improve estimation of stimulus-evoked hemodynamic response from fNIRS measurements

Author keywords

[No Author keywords available]

Indexed keywords

ACCURATE ESTIMATION; AVERAGING TECHNIQUE; BAND PASS FILTERING; CEREBRAL CORTEX; COGNITIVE FUNCTIONS; CONTRAST TO NOISE RATIO; DATA SETS; FUNCTIONAL ACTIVITIES; FUNCTIONAL-NEAR INFRARED; HEART BEATS; HEMODYNAMIC RESPONSE; MOTOR TASKS; NEURO-IMAGING; NOISE COMPONENTS; NON-INVASIVE; NON-PARAMETRIC BAYESIAN; PEAK AMPLITUDE; PRE-PROCESSED DATA; PRE-PROCESSING; RANDOM DISTURBANCES; REFERENCE CHANNELS; SIMULATED DATA;

EID: 84055176413     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6090180     Document Type: Conference Paper
Times cited : (14)

References (18)
  • 1
    • 0010649489 scopus 로고    scopus 로고
    • Noninvasive imaging of cerebral activation with diffuse optical tomography
    • E D. (CRC Press), Chap 8
    • D. A. Boas, M. A. Franceschini, A. K. Dunn, and G. Strangman, "Noninvasive Imaging of Cerebral Activation with Diffuse Optical Tomography", in In Vivo Optical Imaging of Brain Function. E. D. (CRC Press), Chap 8, pp. 193-221, 2002.
    • (2002) Vivo Optical Imaging of Brain Function , pp. 193-221
    • Boas, D.A.1    Franceschini, M.A.2    Dunn, A.K.3    Strangman, G.4
  • 3
    • 4344660240 scopus 로고    scopus 로고
    • Comment on the modified beer-lambert law for scattering media
    • A. Sassaroli, S. Fantini "Comment on the modified Beer-Lambert law for scattering media". Phys. Med. Biol, vol 49, pp N255-N257, 2004.
    • (2004) Phys. Med. Biol , vol.49
    • Sassaroli, A.1    Fantini, S.2
  • 4
    • 1942488239 scopus 로고    scopus 로고
    • Capacity limit of visual short-term memory in human posterior parietal cortex
    • J.J. Todd, R. Marois "Capacity limit of visual short-term memory in human posterior parietal cortex". Nature, vol. 428, pp. 751-754, 2004.
    • (2004) Nature , vol.428 , pp. 751-754
    • Todd, J.J.1    Marois, R.2
  • 5
    • 47949104254 scopus 로고    scopus 로고
    • Selective activation of the superior frontal gyrus in task-switching: An event-related fNIRS study
    • S. Cutini, P. Scatturin, E. Menon, P.S. Bisiacchi, L. Gamberini, M. Zorzi, R. Dell'Acqua "Selective activation of the superior frontal gyrus in task-switching: An event-related fNIRS study". NeuroImage, vol. 42, pp. 945-955, 2008.
    • (2008) NeuroImage , vol.42 , pp. 945-955
    • Cutini, S.1    Scatturin, P.2    Menon, E.3    Bisiacchi, P.S.4    Gamberini, L.5    Zorzi, M.6    Dell'Acqua, R.7
  • 6
    • 0141869792 scopus 로고    scopus 로고
    • Differences in the hemodynamic response to event-related motor and visual paradigms as measured by nearinfrared spectroscopy
    • G. Jasdzewski, G. Strangman, J. Wagner, K.K. Kwong, R.A., Poldrack, D.A. Boas "Differences in the hemodynamic response to event-related motor and visual paradigms as measured by nearinfrared spectroscopy". NeuroImage, vol. 20, pp. 479-488, 2003.
    • (2003) NeuroImage , vol.20 , pp. 479-488
    • Jasdzewski, G.1    Strangman, G.2    Wagner, J.3    Kwong, R.A.K.K.4    Boas P. A, D.5
  • 8
    • 61449093647 scopus 로고    scopus 로고
    • Adaptive filtering to reduce global interference in non-invasive NIRS measures of brain activation: How well and when does it work?
    • Q. Zhang, G.E. Strangman, G. Ganis "Adaptive filtering to reduce global interference in non-invasive NIRS measures of brain activation: How well and when does it work?". NeuroImage, vol. 45, pp. 788-794, 2009.
    • (2009) NeuroImage , vol.45 , pp. 788-794
    • Zhang, Q.1    Strangman, G.E.2    Ganis, G.3
  • 9
    • 77952556048 scopus 로고    scopus 로고
    • Motion artifact removal for functional near infrared spectroscopy: A comparison of methods
    • F.C. Robertson, T.S. Douglas, E.M. Meintjes, "Motion artifact removal for functional near infrared spectroscopy: a comparison of methods". IEEE Trans Biomed Eng vol. 56, pp. 1377-87, 2010.
    • (2010) IEEE Trans Biomed Eng , vol.56 , pp. 1377-1387
    • Robertson, F.C.1    Douglas, T.S.2    Meintjes, E.M.3
  • 10
    • 79952704811 scopus 로고    scopus 로고
    • Two-detector Corrected Near Infrared Spectroscopy (C-NIRS) detects hemodynamic activation responses more robustly than single-detector NIRS
    • to be published
    • R.B. Saager, N.L. Telleri, A.J. Berger, "Two-detector Corrected Near Infrared Spectroscopy (C-NIRS) detects hemodynamic activation responses more robustly than single-detector NIRS". Neuroimage, to be published.
    • Neuroimage
    • Saager, R.B.1    Telleri, N.L.2    Berger, A.J.3
  • 12
    • 78650047778 scopus 로고    scopus 로고
    • Bayesian filtering of human brain hemodynamic activity elicited by visual short-term maintenance recorded through functional nearinfrared spectroscopy (fNIRS)
    • F. Scarpa, S. Cutini, P. Scatturin, R. Dell'Acqua, G. Sparacino "Bayesian filtering of human brain hemodynamic activity elicited by visual short-term maintenance recorded through functional nearinfrared spectroscopy (fNIRS)" Optics Express, vol 18, pp. 26550-26568, 2010.
    • (2010) Optics Express , vol.18 , pp. 26550-26568
    • Scarpa, F.1    Cutini, S.2    Scatturin, P.3    Dell'acqua, R.4    Sparacino, G.5
  • 13
    • 84055198158 scopus 로고    scopus 로고
    • Evaluation of a standardized sine wave fit algorithm
    • P. Handel, "Evaluation of a standardized sine wave fit algorithm", Proc. IEEE NORSIG, 2000.
    • (2000) Proc. IEEE NORSIG
    • Handel, P.1
  • 15
    • 78649683027 scopus 로고    scopus 로고
    • A new method based on ICBM152 head surface for probe placement in multichannel fNIRS
    • S. Cutini, P. Scatturin, M. Zorzi "A new method based on ICBM152 head surface for probe placement in multichannel fNIRS". Neuroimage, vol 54, pp. 919-927, 2011.
    • (2011) Neuroimage , vol.54 , pp. 919-927
    • Cutini, S.1    Scatturin, P.2    Zorzi, M.3
  • 16
    • 34547880428 scopus 로고    scopus 로고
    • Validity and power in hemodynamic response modeling: A comparison study and a new approach
    • M. A. Lindquist, and T. D. Wager, "Validity and power in hemodynamic response modeling: a comparison study and a new approach," Hum. Brain Mapp, vol 28, pp. 764-784, 2007.
    • (2007) Hum. Brain Mapp , vol.28 , pp. 764-784
    • Lindquist, M.A.1    Wager, T.D.2
  • 17
    • 74049140849 scopus 로고    scopus 로고
    • Comparison of principal and independent component analysis in removing extracerebral interference from near-infrared spectroscopy signals
    • J. Virtanen, T. Noponen, P. Meriläinen, "Comparison of principal and independent component analysis in removing extracerebral interference from near-infrared spectroscopy signals". Journal of Biomedical Optics, vol. 14, pp. 054032, 2009.
    • (2009) Journal of Biomedical Optics , vol.14 , pp. 054032
    • Virtanen, J.1    Noponen, T.2    Meriläinen, P.3
  • 18
    • 1842557501 scopus 로고    scopus 로고
    • Practicality of wavelength selection to improve signal-to-noise ratio in near-infrared spectroscopy
    • H. Sato, M. Kiguchi, F. Kawaguchi, A. Maki, "Practicality of wavelength selection to improve signal-to-noise ratio in near-infrared spectroscopy". NeuroImage, vol 21, pp. 1554-1562, 2004.
    • (2004) NeuroImage , vol.21 , pp. 1554-1562
    • Sato, H.1    Kiguchi, M.2    Kawaguchi, F.3    Maki, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.