메뉴 건너뛰기




Volumn 25, Issue 1, 2012, Pages 56-65

Automated quantification of mitral inflow and aortic outflow stroke volumes by three-dimensional real-time volume color-flow doppler transthoracic echocardiography: Comparison with pulsed-wave doppler and cardiac magnetic resonance imaging

Author keywords

2D; 3D; Cardiac magnetic resonance; CFD; CI; CMR; Color flow Doppler; Confidence interval; Left ventricular; Left ventricular outflow tract; LV; LVOT; Pulsed wave; PW; Real time three dimensional volume color flow Doppler transthoracic echocardiography; Region of interest; ROI; RT VCFD; Stroke volume; SV; Three dimensional; Transthoracic echocardiography; TTE; Two dimensional

Indexed keywords

ADULT; ALGORITHM; AORTA; AORTA FLOW; ARTICLE; CARDIOVASCULAR MAGNETIC RESONANCE; CLINICAL ARTICLE; COMPARATIVE STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DOPPLER ECHOGRAPHY; FEASIBILITY STUDY; FEMALE; HEART LEFT VENTRICLE EJECTION FRACTION; HEART STROKE VOLUME; HEART VENTRICLE FUNCTION; HUMAN; INTERMETHOD COMPARISON; MALE; MEASUREMENT; MITRAL VALVE; PULSED WAVE DOPPLER; REAL TIME THREE DIMENSIONAL VOLUME COLOR FLOW DOPPLER TRANSTHORACIC ECHOCARDIOGRAPHY; REPRODUCIBILITY; TRANSTHORACIC ECHOCARDIOGRAPHY; TWO DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 84055165136     PISSN: 08947317     EISSN: 10976795     Source Type: Journal    
DOI: 10.1016/j.echo.2011.10.004     Document Type: Article
Times cited : (93)

References (31)
  • 3
    • 0034584599 scopus 로고    scopus 로고
    • Velocity profiles in mitral blood flow based on three-dimensional freehand colour flow imaging acquired at high frame rate
    • B.O. Haugen, S. Berg, K.M. Brecke, S.O. Samstad, S.A. Slordahl, and T. Skjaerpe Velocity profiles in mitral blood flow based on three-dimensional freehand colour flow imaging acquired at high frame rate Eur J Echocardiogr 1 2000 252 256
    • (2000) Eur J Echocardiogr , vol.1 , pp. 252-256
    • Haugen, B.O.1    Berg, S.2    Brecke, K.M.3    Samstad, S.O.4    Slordahl, S.A.5    Skjaerpe, T.6
  • 4
    • 0029362367 scopus 로고
    • Measurement of aortic blood flow by Doppler echocardiography: Temporal, technician, and reader variability in normal subjects and the application of generalizability theory in clinical research
    • F. Kusumoto, T. Venet, N.B. Schiller, A. Sebastian, and E. Foster Measurement of aortic blood flow by Doppler echocardiography: temporal, technician, and reader variability in normal subjects and the application of generalizability theory in clinical research J Am Soc Echocardiogr 8 1995 647 653
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 647-653
    • Kusumoto, F.1    Venet, T.2    Schiller, N.B.3    Sebastian, A.4    Foster, E.5
  • 5
    • 0003142439 scopus 로고
    • Doppler estimation of volumetric flow
    • A. Weyman, 2nd ed. Lea & Febiger Philadelphia, PA
    • S. Marshall, and A. Weyman Doppler estimation of volumetric flow A. Weyman, Principles and practice of echocardiography 2nd ed. 1994 Lea & Febiger Philadelphia, PA 955 978
    • (1994) Principles and Practice of Echocardiography , pp. 955-978
    • Marshall, S.1    Weyman, A.2
  • 6
    • 0034286311 scopus 로고    scopus 로고
    • Measurement of volumetric mitral and aortic blood flow based on a new freehand three-dimensional colour flow imaging method. An in vivo validation
    • B.O. Haugen, S. Berg, K.M. Brecke, S.O. Samstad, T. Skjaerpe, and S.A. Slordahl Measurement of volumetric mitral and aortic blood flow based on a new freehand three-dimensional colour flow imaging method. An in vivo validation Eur J Echocardiogr 1 2000 204 212
    • (2000) Eur J Echocardiogr , vol.1 , pp. 204-212
    • Haugen, B.O.1    Berg, S.2    Brecke, K.M.3    Samstad, S.O.4    Skjaerpe, T.5    Slordahl, S.A.6
  • 7
    • 19944391883 scopus 로고    scopus 로고
    • A real-time 3-dimensional digital Doppler method for measurement of flow rate and volume through mitral valve in children: A validation study compared with magnetic resonance imaging
    • DOI 10.1016/j.echo.2004.08.021, PII S0894731704007205
    • S. Ge, L. Bu, H. Zhang, E. Schelbert, M. Disterhoft, and X. Li A real-time 3-dimensional digital Doppler method for measurement of flow rate and volume through mitral valve in children: a validation study compared with magnetic resonance imaging J Am Soc Echocardiogr 18 2005 1 7 (Pubitemid 40051188)
    • (2005) Journal of the American Society of Echocardiography , vol.18 , Issue.1 , pp. 1-7
    • Ge, S.1    Bu, L.2    Zhang, H.3    Schelbert, E.4    Disterhoft, M.5    Li, X.6    Li, X.7    Sahn, D.8    Stolpen, A.9    Sonka, M.10
  • 10
    • 23044433160 scopus 로고    scopus 로고
    • Real-time 3-dimensional Doppler echocardiography for the assessment of stroke volume: An in vivo human study compared with standard 2-dimensional echocardiography
    • DOI 10.1016/j.echo.2005.03.009, PII S0894731705002300
    • J. Pemberton, X. Li, A. Kenny, C.H. Davies, M.S. Minette, and D.J. Sahn Real-time 3-dimensional Doppler echocardiography for the assessment of stroke volume: an in vivo human study compared with standard 2-dimensional echocardiography J Am Soc Echocardiogr 18 2005 1030 1036 (Pubitemid 41411937)
    • (2005) Journal of the American Society of Echocardiography , vol.18 , Issue.10 , pp. 1030-1036
    • Pemberton, J.1    Li, X.2    Kenny, A.3    Davies, C.H.4    Minette, M.S.5    Sahn, D.J.6
  • 11
    • 0036708271 scopus 로고    scopus 로고
    • Surface integration of velocity vectors from 3D digital colour doppler: An angle independent method for laminar flow measurements
    • DOI 10.1053/euje.2002.0145
    • R.A. Rusk, X.N. Li, T. Irvine, Y. Mori, S. Wanitkun, and X.K. Li Surface integration of velocity vectors from 3D digital colour Doppler: an angle independent method for laminar flow measurements Eur J Echocardiogr 3 2002 177 184 (Pubitemid 34960155)
    • (2002) European Journal of Echocardiography , vol.3 , Issue.3 , pp. 177-184
    • Rusk, R.A.1    Li, X.-N.2    Irvine, T.3    Mori, Y.4    Wanitkun, S.5    Li, X.-K.6    Kenny, A.7    Sahn, D.J.8
  • 12
    • 33846011425 scopus 로고    scopus 로고
    • Real-time Three-dimensional Color Doppler Echocardiography Overcomes the Inaccuracies of Spectral Doppler for Stroke Volume Calculation
    • DOI 10.1016/j.echo.2006.05.010, PII S0894731706005311
    • J. Pemberton, S. Ge, K. Thiele, M. Jerosch-Herold, and D.J. Sahn Real-time three-dimensional color Doppler echocardiography overcomes the inaccuracies of spectral Doppler for stroke volume calculation J Am Soc Echocardiogr 19 2006 1403 1410 (Pubitemid 46053692)
    • (2006) Journal of the American Society of Echocardiography , vol.19 , Issue.11 , pp. 1403-1410
    • Pemberton, J.1    Ge, S.2    Thiele, K.3    Jerosch-Herold, M.4    Sahn, D.J.5
  • 14
    • 56549087880 scopus 로고    scopus 로고
    • Direct quantification of mitral regurgitant flow volume by real-time three-dimensional echocardiography using dealiasing of color Doppler flow at the vena contracta
    • B. Plicht, P. Kahlert, R. Goldwasser, R.A. Janosi, P. Hunold, and R. Erbel Direct quantification of mitral regurgitant flow volume by real-time three-dimensional echocardiography using dealiasing of color Doppler flow at the vena contracta J Am Soc Echocardiogr 21 2008 1337 1346
    • (2008) J Am Soc Echocardiogr , vol.21 , pp. 1337-1346
    • Plicht, B.1    Kahlert, P.2    Goldwasser, R.3    Janosi, R.A.4    Hunold, P.5    Erbel, R.6
  • 15
    • 50249107876 scopus 로고    scopus 로고
    • Accuracy of real-time, three-dimensional Doppler echocardiography for stroke volume estimation compared with phase-encoded MRI: An in vivo study
    • J. Pemberton, M. Jerosch-Herold, X. Li, L. Hui, M. Silberbach, and W. Woodward Accuracy of real-time, three-dimensional Doppler echocardiography for stroke volume estimation compared with phase-encoded MRI: an in vivo study Heart 94 2008 1212 1213
    • (2008) Heart , vol.94 , pp. 1212-1213
    • Pemberton, J.1    Jerosch-Herold, M.2    Li, X.3    Hui, L.4    Silberbach, M.5    Woodward, W.6
  • 16
    • 34548190475 scopus 로고    scopus 로고
    • Current Status of Three-Dimensional Color Flow Doppler
    • DOI 10.1016/j.ccl.2007.06.006, PII S0733865107000483, Three-Dimensional Echocardiography
    • L. Sugeng, and R.M. Lang Current status of three-dimensional color flow Doppler Cardiol Clin 25 2007 297 303 (Pubitemid 47313595)
    • (2007) Cardiology Clinics , vol.25 , Issue.2 , pp. 297-303
    • Sugeng, L.1    Lang, R.M.2
  • 19
    • 54949104993 scopus 로고    scopus 로고
    • Four-chamber heart modeling and automatic segmentation for 3-D cardiac CT volumes using marginal space learning and steerable features
    • Y. Zheng, A. Barbu, B. Georgescu, M. Scheuering, and D. Comaniciu Four-chamber heart modeling and automatic segmentation for 3-D cardiac CT volumes using marginal space learning and steerable features TMI 27 2008 1668 1681
    • (2008) TMI , vol.27 , pp. 1668-1681
    • Zheng, Y.1    Barbu, A.2    Georgescu, B.3    Scheuering, M.4    Comaniciu, D.5
  • 20
    • 77953827096 scopus 로고    scopus 로고
    • A novel operator-independent algorithm for cardiac output measurements based on three-dimensional transoesophageal colour Doppler echocardiography
    • F. Matthews, T. Largiader, P. Rhomberg, B. van der Loo, E.R. Schmid, and R. Jenni A novel operator-independent algorithm for cardiac output measurements based on three-dimensional transoesophageal colour Doppler echocardiography Eur J Echocardiogr 11 2010 432 437
    • (2010) Eur J Echocardiogr , vol.11 , pp. 432-437
    • Matthews, F.1    Largiader, T.2    Rhomberg, P.3    Van Der Loo, B.4    Schmid, E.R.5    Jenni, R.6
  • 21
    • 51649099259 scopus 로고    scopus 로고
    • Standardized cardiovascular magnetic resonance imaging (CMR) protocols, Society for Cardiovascular Magnetic Resonance: Board of Trustees Task Force on Standardized Protocols
    • C.M. Kramer, J. Barkhausen, S.D. Flamm, R.J. Kim, and E. Nagel Standardized cardiovascular magnetic resonance imaging (CMR) protocols, Society for Cardiovascular Magnetic Resonance: Board of Trustees Task Force on Standardized Protocols J Cardiovasc Magn Reson 10 2008 35
    • (2008) J Cardiovasc Magn Reson , vol.10 , pp. 35
    • Kramer, C.M.1    Barkhausen, J.2    Flamm, S.D.3    Kim, R.J.4    Nagel, E.5
  • 22
    • 0036481560 scopus 로고    scopus 로고
    • Recommendations for quantification of Doppler echocardiography: A report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography
    • M.A. Quinones, C.M. Otto, M. Stoddard, A. Waggoner, and W.A. Zoghbi Recommendations for quantification of Doppler echocardiography: a report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography J Am Soc Echocardiogr 15 2002 167 184
    • (2002) J Am Soc Echocardiogr , vol.15 , pp. 167-184
    • Quinones, M.A.1    Otto, C.M.2    Stoddard, M.3    Waggoner, A.4    Zoghbi, W.A.5
  • 25
    • 0025286923 scopus 로고
    • Left ventricular volume measurement using cardiac axis nuclear magnetic resonance imaging. Validation by calibrated ventricular angiography
    • G.B. Cranney, C.S. Lotan, L. Dean, W. Baxley, A. Bouchard, and G.M. Pohost Left ventricular volume measurement using cardiac axis nuclear magnetic resonance imaging. Validation by calibrated ventricular angiography Circulation 82 1990 154 163 (Pubitemid 20216326)
    • (1990) Circulation , vol.82 , Issue.1 , pp. 154-163
    • Cranney, G.B.1    Lotan, C.S.2    Dean, L.3    Baxley, W.4    Bouchard, A.5    Pohost, G.M.6
  • 27
    • 0029101334 scopus 로고
    • Magnetic resonance imaging assessment of the severity of mitral regurgitation. Comparison with invasive techniques
    • W.G. Hundley, H.F. Li, J.E. Willard, C. Landau, R.A. Lange, and B.M. Meshack Magnetic resonance imaging assessment of the severity of mitral regurgitation. Comparison with invasive techniques Circulation 92 1995 1151 1158
    • (1995) Circulation , vol.92 , pp. 1151-1158
    • Hundley, W.G.1    Li, H.F.2    Willard, J.E.3    Landau, C.4    Lange, R.A.5    Meshack, B.M.6
  • 28
    • 33745920179 scopus 로고    scopus 로고
    • Severity of mitral and aortic regurgitation as assessed by cardiovascular magnetic resonance: Optimizing correlation with Doppler echocardiography
    • E.V. Gelfand, S. Hughes, T.H. Hauser, S.B. Yeon, L. Goepfert, and K.V. Kissinger Severity of mitral and aortic regurgitation as assessed by cardiovascular magnetic resonance: optimizing correlation with Doppler echocardiography J Cardiovasc Magn Reson 8 2006 503 507
    • (2006) J Cardiovasc Magn Reson , vol.8 , pp. 503-507
    • Gelfand, E.V.1    Hughes, S.2    Hauser, T.H.3    Yeon, S.B.4    Goepfert, L.5    Kissinger, K.V.6
  • 29
    • 7044286097 scopus 로고    scopus 로고
    • Quantification of regurgitant fraction in mitral regurgitation by cardiovascular magnetic resonance: Comparison of techniques
    • M.W. Kon, S.G. Myerson, N.E. Moat, and D.J. Pennell Quantification of regurgitant fraction in mitral regurgitation by cardiovascular magnetic resonance: comparison of techniques J Heart Valve Dis 13 2004 600 607
    • (2004) J Heart Valve Dis , vol.13 , pp. 600-607
    • Kon, M.W.1    Myerson, S.G.2    Moat, N.E.3    Pennell, D.J.4
  • 30
    • 78650284120 scopus 로고    scopus 로고
    • Quantitative assessment of mitral regurgitation: Comparison between three-dimensional transesophageal echocardiography and magnetic resonance imaging
    • M. Shanks, H.M. Siebelink, V. Delgado, N.R. van de Veire, A.C. Ng, and A. Sieders Quantitative assessment of mitral regurgitation: comparison between three-dimensional transesophageal echocardiography and magnetic resonance imaging Circ Cardiovasc Imaging 3 2010 694 700
    • (2010) Circ Cardiovasc Imaging , vol.3 , pp. 694-700
    • Shanks, M.1    Siebelink, H.M.2    Delgado, V.3    Van De Veire, N.R.4    Ng, A.C.5    Sieders, A.6
  • 31
    • 84155168729 scopus 로고    scopus 로고
    • Correction of phase offset errors in cardiovascular magnetic resonance using background subtraction from stationary tissue
    • N. Misra, A.M. Shah, and W.W. Lai Correction of phase offset errors in cardiovascular magnetic resonance using background subtraction from stationary tissue J Cardiovasc Magn Reson 13 suppl 2011 213
    • (2011) J Cardiovasc Magn Reson , vol.13 , Issue.SUPPL. , pp. 213
    • Misra, N.1    Shah, A.M.2    Lai, W.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.