메뉴 건너뛰기




Volumn 60, Issue , 2012, Pages 86-90

Quantification of potential impurities by a stability indicating UV-HPLC method in niacinamide active pharmaceutical ingredient

Author keywords

Forced degradation; Impurity; Niacinamide; Validation

Indexed keywords

NICOTINAMIDE;

EID: 83955165305     PISSN: 07317085     EISSN: 1873264X     Source Type: Journal    
DOI: 10.1016/j.jpba.2011.10.033     Document Type: Article
Times cited : (12)

References (14)
  • 1
    • 83955164710 scopus 로고    scopus 로고
    • Pharmaceutical Press, London, S.C. Sweetman (Ed.)
    • Martindale-The Complete Drug Reference 2011, 2117-2120. Pharmaceutical Press, London. 36th ed. S.C. Sweetman (Ed.).
    • (2011) Martindale-The Complete Drug Reference , pp. 2117-2120
  • 2
    • 1642422341 scopus 로고
    • Niacin versus niacinamide
    • Jaconello P. Niacin versus niacinamide. CMAJ 1992, 147:990b.
    • (1992) CMAJ , vol.147
    • Jaconello, P.1
  • 3
    • 0033011536 scopus 로고    scopus 로고
    • Nicotinamide in type 1 diabetes
    • Kolb H., Burkart V. Nicotinamide in type 1 diabetes. Diabetes Care 1999, 22:B16-B20.
    • (1999) Diabetes Care , vol.22
    • Kolb, H.1    Burkart, V.2
  • 4
    • 0019350456 scopus 로고
    • Simultaneous determination of niacinamide, pyridoxine, riboflavin, and thiamine in multivitamin products by high-pressure liquid chromatography
    • Walker M.C., Carpenter B.E., Cooper E.L. Simultaneous determination of niacinamide, pyridoxine, riboflavin, and thiamine in multivitamin products by high-pressure liquid chromatography. J. Pharm. Sci. 1981, 70:99-101.
    • (1981) J. Pharm. Sci. , vol.70 , pp. 99-101
    • Walker, M.C.1    Carpenter, B.E.2    Cooper, E.L.3
  • 5
    • 0018159511 scopus 로고
    • Simultaneous determination of niacin, niacinamide, pyridoxine, thiamine, and riboflavin in multivitamin blends by ion-pair high-pressure liquid chromatography
    • Kirchmeier R.L., Upton R.P. Simultaneous determination of niacin, niacinamide, pyridoxine, thiamine, and riboflavin in multivitamin blends by ion-pair high-pressure liquid chromatography. J. Pharm. Sci. 1978, 67:1444-1446.
    • (1978) J. Pharm. Sci. , vol.67 , pp. 1444-1446
    • Kirchmeier, R.L.1    Upton, R.P.2
  • 6
    • 0028435485 scopus 로고
    • Identification of isonicotinic acid in niacin by liquid chromatography with diode array detection
    • Kirchhoefer R.D., Niacin I.I. Identification of isonicotinic acid in niacin by liquid chromatography with diode array detection. J. AOAC Int. 1994, 77:587-590.
    • (1994) J. AOAC Int. , vol.77 , pp. 587-590
    • Kirchhoefer, R.D.1    Niacin, I.I.2
  • 7
    • 0024207768 scopus 로고
    • Simultaneous determination of niacin and niacinamide in meats by high-performance liquid chromatography
    • Takashi H., Yukimasa M., Nobumi A., Yamamoto S., Oji Y. Simultaneous determination of niacin and niacinamide in meats by high-performance liquid chromatography. J. Chromatogr. 1988, 457:403-408.
    • (1988) J. Chromatogr. , vol.457 , pp. 403-408
    • Takashi, H.1    Yukimasa, M.2    Nobumi, A.3    Yamamoto, S.4    Oji, Y.5
  • 14
    • 84855497798 scopus 로고    scopus 로고
    • http://www.drugs.com/mmx/niacinamide.html.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.