메뉴 건너뛰기




Volumn , Issue , 2011, Pages 86-89

A low-loss rectifier unit for inductive-powering of biomedical implants

Author keywords

[No Author keywords available]

Indexed keywords

BATTERY-LESS; BIOMEDICAL IMPLANTS; CROSS-COUPLED; FULL BRIDGE; FULL BRIDGE RECTIFIER; INDUCTIVE LINK; LC TANKS; LC-OSCILLATORS; LOW LOSS; MOS SWITCHES; MOS-FET; OVERALL EFFICIENCY; POWER-LOSSES; POWERING SYSTEMS; REAL TIME MONITORING; RECTIFIER CIRCUIT; STANDARD CMOS PROCESS;

EID: 83755163065     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/VLSISoC.2011.6081656     Document Type: Conference Paper
Times cited : (18)

References (10)
  • 1
    • 0032053980 scopus 로고    scopus 로고
    • An externally powered, multichannel implantable stimulator-telemeter for control of paralyzed muscle
    • Apr.
    • B. S. Z. Tang, M. W. Johnson, S. Pourmehdy, M. M. Gazdik, J. R. Buckett, and P. H. Peckham, "An externally powered, multichannel implantable stimulator-telemeter for control of paralyzed muscle,"IEEE Trans. Biomed. Eng., no. 4, pp. 463-475, Apr. 1998.
    • (1998) IEEE Trans. Biomed. Eng. , Issue.4 , pp. 463-475
    • Tang, B.S.Z.1    Johnson, M.W.2    Pourmehdy, S.3    Gazdik, M.M.4    Buckett, J.R.5    Peckham, P.H.6
  • 2
    • 72649087105 scopus 로고    scopus 로고
    • Beamformer suppression of cochlear implant artifacts in an electroencephalography dataset
    • Nov.
    • D. D. E. Wong and K. A. Gordon, "Beamformer suppression of cochlear implant artifacts in an electroencephalography dataset" IEEE Trans. Biomed. Eng., pp. 2851-2857, Nov. 2009.
    • (2009) IEEE Trans. Biomed. Eng. , pp. 2851-2857
    • Wong, D.D.E.1    Gordon, K.A.2
  • 4
    • 0035078512 scopus 로고    scopus 로고
    • CMOS neuro-stimulation ASIC with 100 channels, scalable output, and bidirectional radio-freq. telemetry
    • Feb.
    • G. J. Suaning and N. H. Lovell, "CMOS neuro-stimulation ASIC with 100 channels, scalable output, and bidirectional radio-freq. telemetry,"IEEE Trans. Biomed. Eng., vol. 48, pp. 248-260, Feb. 2001.
    • (2001) IEEE Trans. Biomed. Eng. , vol.48 , pp. 248-260
    • Suaning, G.J.1    Lovell, N.H.2
  • 5
    • 0017559930 scopus 로고
    • Design of radio-frequency powered coils for implant instruments
    • W. H. Ko, S. P. Liang, and C. D. F. Fung, "Design of radio-frequency powered coils for implant instruments," Med. Biol. Eng. Comput. 15: 634-640, 1977.
    • (1977) Med. Biol. Eng. Comput. , vol.15 , pp. 634-640
    • Ko, W.H.1    Liang, S.P.2    Fung, C.D.F.3
  • 6
    • 0023324937 scopus 로고
    • RADIO-FREQUENCY COILS IN IMPLANTABLE DEVICES: MISALIGNMENT ANALYSIS AND DESIGN PROCEDURE.
    • M. Soma, D. C. Galbraith, and R. L. White, "Radio-frequency coils in implantable devices: misalignment analysis and design procedure,"IEEE Trans. Biomed. Eng. 34:276-282, Apr. 1987. (Pubitemid 17565728)
    • (1987) IEEE Transactions on Biomedical Engineering , vol.BME-34 , Issue.4 , pp. 276-282
    • Soma, M.1    Galbraith, D.C.2    White, R.L.3
  • 7
    • 77956595751 scopus 로고    scopus 로고
    • Power-oscillator based high efficiency inductive power link for transcutaneous power transmission
    • Seattle, WA, August 1-4
    • Q. Ma, M. R. Haider, S. Yuan, and S. K. Islam, "Power-oscillator based high efficiency inductive power link for transcutaneous power transmission," 53rd IEEE International Midwest Symposium on Circuits and Systems, pp. 537-540, Seattle, WA, August 1-4, 2010
    • (2010) 53rd IEEE International Midwest Symposium on Circuits and Systems , pp. 537-540
    • Ma, Q.1    Haider, M.R.2    Yuan, S.3    Islam, S.K.4
  • 8
    • 73249134340 scopus 로고    scopus 로고
    • An efficient piezoelectric energy harvesting interface circuit using a bias-flip rectifier and shared inductor
    • Jan
    • Y. K. Ramadass and A. P. Chandrakasan, "An efficient piezoelectric energy harvesting interface circuit using a bias-flip rectifier and shared inductor,"IEEE Journal of Solid-State Circuits, vol. 45, no. 1, pp. 189-204, Jan 2010.
    • (2010) IEEE Journal of Solid-State Circuits , vol.45 , Issue.1 , pp. 189-204
    • Ramadass, Y.K.1    Chandrakasan, A.P.2
  • 10
    • 34548852907 scopus 로고    scopus 로고
    • Incorporating back telemetry in a full-wave CMOS rectifier for RFID and biomedical applications
    • May 27-30, New Orleans, LA
    • S. Atluri and M. Ghovanloo,"Incorporating back telemetry in a full-wave CMOS rectifier for RFID and biomedical applications," IEEE International Symposium on Circuits and Systems, pp. 801-804, May 27-30, New Orleans, LA, 2007.
    • (2007) IEEE International Symposium on Circuits and Systems , pp. 801-804
    • Atluri, S.1    Ghovanloo, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.