메뉴 건너뛰기




Volumn 45, Issue 1, 2012, Pages 188-196

Use of modelling error dynamics for the calibration of water distribution systems

Author keywords

Calibration; Demand; Modelling; Optimization; Roughness; Water distribution system

Indexed keywords

ERRORS; LOCAL AREA NETWORKS; OPTIMIZATION; SURFACE ROUGHNESS; SYSTEMATIC ERRORS; WATER DISTRIBUTION SYSTEMS;

EID: 83555166334     PISSN: 09659978     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.advengsoft.2011.09.024     Document Type: Article
Times cited : (15)

References (16)
  • 1
    • 84858406021 scopus 로고    scopus 로고
    • The use of error dynamics for calibration of water distribution systems
    • Topping BHV, Costa Neves LF, Barros RC, editors Stirlingshire (UK): Civil-Comp Press doi:10.4203/ccp.91.247 [Paper 247]
    • Koppel T, Vassiljev A. The use of error dynamics for calibration of water distribution systems. In: Topping BHV, Costa Neves LF, Barros RC, editors. Proceedings of the twelfth international conference on civil, structural and environmental engineering computing. Stirlingshire (UK): Civil-Comp Press; 2009. doi: 10.4203/ccp.91.247 [Paper 247].
    • (2009) Proceedings of the Twelfth International Conference on Civil, Structural and Environmental Engineering Computing
    • Koppel, T.1    Vassiljev, A.2
  • 2
    • 0035310447 scopus 로고    scopus 로고
    • Calibration assessment and data collection for water distribution networks
    • DOI 10.1061/(ASCE)0733-9429(2001)127:4(270)
    • K.E. Lansey, W. El-Shorbagy, I. Ahmed, J. Araujo, and C.T. Haan Calibration assessment and data collection for water distribution networks J Hydraul Eng - ASCE 127 2001 270 279 (Pubitemid 32320609)
    • (2001) Journal of Hydraulic Engineering , vol.127 , Issue.4 , pp. 270-279
    • Lansey, K.E.1    El-Shorbagy, W.2    Ahmed, I.3    Araujo, J.4    Haan, C.T.5
  • 3
    • 0032725987 scopus 로고    scopus 로고
    • New approach to water distribution network calibration
    • DOI 10.1061/(ASCE)0733-9429(1999)125:8(849)
    • M. Greco, and G.D. Giudice New approach to water distribution network calibration J Hydraul Eng 125 8 1999 849 854 (Pubitemid 29495172)
    • (1999) Journal of Hydraulic Engineering , vol.125 , Issue.8 , pp. 849-854
    • Greco, M.1    Del Giudice, G.2
  • 4
    • 0033640007 scopus 로고    scopus 로고
    • Model calibration data: The good, the bad, and the useless
    • T.M. Walski Model calibration data: the good, the bad, and the useless J AWWA 92 1 2000 94 99 (Pubitemid 32212376)
    • (2000) Journal / American Water Works Association , vol.92 , Issue.1 , pp. 94-99
    • Walski, T.M.1
  • 5
  • 7
  • 8
    • 64849092450 scopus 로고    scopus 로고
    • Calibration of a model of an operational water distribution system containing pipes of different age
    • T. Koppel, and A. Vassiljev Calibration of a model of an operational water distribution system containing pipes of different age Adv Eng Softw 40 2009 659 664
    • (2009) Adv Eng Softw , vol.40 , pp. 659-664
    • Koppel, T.1    Vassiljev, A.2
  • 9
    • 69949100235 scopus 로고    scopus 로고
    • Design, expansion and rehabilitation of water distribution networks aimed at reducing water losses. Where are we?
    • Van Zyl JE, Ilemobade AA, Jacobs HE, editors Kruger National Park, South Africa
    • Todini E. Design, expansion and rehabilitation of water distribution networks aimed at reducing water losses. Where are we? In: Van Zyl JE, Ilemobade AA, Jacobs HE, editors. Proceedings of the 10th annual water distribution systems analysis conference (WDSA2008). Kruger National Park, South Africa. p. 374-91.
    • Proceedings of the 10th Annual Water Distribution Systems Analysis Conference (WDSA2008) , pp. 374-391
    • Todini, E.1
  • 10
    • 27544455329 scopus 로고    scopus 로고
    • Evaluation of leakage by means of night flow measurements and analytical discrimination. A comparative study
    • Cabrera E, Cabrera Jr. E, editors Lisse: Swets & Zetlinger
    • Almandoz J, Cabrera E, Gil J, Pellejero I. Evaluation of leakage by means of night flow measurements and analytical discrimination. A comparative study. In: Cabrera E, Cabrera Jr E, editors. Pumps, electromechanical devices and systems applied to urban water management. Lisse: Swets & Zetlinger; 2003. p. 327-41.
    • (2003) Pumps, Electromechanical Devices and Systems Applied to Urban Water Management , pp. 327-341
    • Almandoz, J.1    Cabrera, E.2    Gil, J.3    Pellejero, I.4
  • 11
    • 40549097541 scopus 로고    scopus 로고
    • The minimum night flow method revisited
    • Buchberger SG, Clark RM, Grayman WM, Uber JG, Editors Cincinnati, Ohio (USA): ASCE
    • Garcia VJ, Cabrera E, Cabrera Jr E. The minimum night flow method revisited. In: Buchberger SG, Clark RM, Grayman WM, Uber JG, editors. 8th Annual water distribution systems analysis symposium. Cincinnati, Ohio (USA): ASCE; 2006. p. 27-30.
    • (2006) 8th Annual Water Distribution Systems Analysis Symposium , pp. 27-30
    • Garcia, V.J.1    Cabrera, E.2    Cabrera Jr., E.3
  • 14
    • 0003606110 scopus 로고    scopus 로고
    • Water Supply and Water Resources Division, National Risk Management Research Laboratory, Cincinnati, OH 45268, September
    • Rossman LA. EPANET 2 user's manual. Water Supply and Water Resources Division, National Risk Management Research Laboratory, Cincinnati, OH 45268, September, 2002.
    • (2002) EPANET 2 User's Manual
    • Rossman, L.A.1
  • 15
    • 2642522515 scopus 로고
    • Valve control regulation for reducing leakage
    • E. Cabrera, A.F. Vela, Kluwer Academic Publishers Dordrecht, Boston, London
    • G. Germanopoulos Valve control regulation for reducing leakage E. Cabrera, A.F. Vela, Improving efficiency and reliability in water distribution systems 1995 Kluwer Academic Publishers Dordrecht, Boston, London 165 188
    • (1995) Improving Efficiency and Reliability in Water Distribution Systems , pp. 165-188
    • Germanopoulos, G.1
  • 16
    • 68149172941 scopus 로고    scopus 로고
    • Unified parameter optimization approach for leakage detection and extended-period simulation model calibration
    • Z.Y. Wu Unified parameter optimization approach for leakage detection and extended-period simulation model calibration Urban Water J 6 1 2009 53 67
    • (2009) Urban Water J , vol.6 , Issue.1 , pp. 53-67
    • Wu, Z.Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.