메뉴 건너뛰기




Volumn 21, Issue 12, 2011, Pages 2511-2520

The value of flat-detector computed tomography during catheterisation of congenital heart disease

Author keywords

Cardiac catheterization; Congenital heart disease; Flat detector CT; Rotational angiography; Three dimensional

Indexed keywords

CONTRAST MEDIUM;

EID: 83555165060     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-011-2214-3     Document Type: Article
Times cited : (26)

References (23)
  • 1
    • 0031546042 scopus 로고    scopus 로고
    • Use of a C-arm system to generate true three-dimensional computed rotational angiograms: Preliminary in vitro and in vivo results
    • R Fahrig AJ Fox S Lownie DW Holdsworth 1997 Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results AJNR Am J Neuroradiol 18 1507 1514 9296192 1:STN:280:DyaK2svktF2ksQ%3D%3D (Pubitemid 30413966)
    • (1997) American Journal of Neuroradiology , vol.18 , Issue.8 , pp. 1507-1514
    • Fahrig, R.1    Fox, A.J.2    Lownie, S.3    Holdsworth, D.W.4
  • 2
    • 58149396296 scopus 로고    scopus 로고
    • Flat-panel volume CT: Fundamental principles, technology, and applications
    • 19001655 10.1148/rg.287085004
    • R Gupta AC Cheung SH Bartling, et al. 2008 Flat-panel volume CT: fundamental principles, technology, and applications RadioGraphics 28 2009 2022 19001655 10.1148/rg.287085004
    • (2008) RadioGraphics , vol.28 , pp. 2009-2022
    • Gupta, R.1    Cheung, A.C.2    Bartling, S.H.3
  • 3
    • 35349003753 scopus 로고    scopus 로고
    • Flat-detector computed tomography (FD-CT)
    • DOI 10.1007/s00330-007-0651-9
    • WA Kalender Y Kyriakou 2007 Flat-detector computed tomography (FD-CT) Eur Radiol 17 2767 2779 17587058 10.1007/s00330-007-0651-9 (Pubitemid 47603972)
    • (2007) European Radiology , vol.17 , Issue.11 , pp. 2767-2779
    • Kalender, W.A.1    Kyriakou, Y.2
  • 4
    • 35548984169 scopus 로고    scopus 로고
    • Contrast-enhanced abdominal angiographic ct for intra-abdominal tumor embolization: A new tool for vessel and soft tissue visualization
    • DOI 10.1007/s00270-007-9029-2
    • BC Meyer BB Frericks T Albrecht KJ Wolf FK Wacker 2007 Contrast-enhanced abdominal angiographic CT for intra-abdominal tumor embolization: a new tool for vessel and soft tissue visualization Cardiovasc Intervent Radiol 30 743 749 17533549 10.1007/s00270-007-9029-2 (Pubitemid 350092250)
    • (2007) CardioVascular and Interventional Radiology , vol.30 , Issue.4 , pp. 743-749
    • Meyer, B.C.1    Frericks, B.B.2    Albrecht, T.3    Wolf, K.-J.4    Wacker, F.K.5
  • 5
    • 59749085081 scopus 로고    scopus 로고
    • Three-dimensional left atrial and esophagus reconstruction using cardiac C-arm computed tomography with image integration into fluoroscopic views for ablation of atrial fibrillation: Accuracy of a novel modality in comparison with multislice computed tomography
    • 10.1016/j.hrthm.2008.09.011
    • G Nolker KJ Gutleben H Marschang, et al. 2008 Three-dimensional left atrial and esophagus reconstruction using cardiac C-arm computed tomography with image integration into fluoroscopic views for ablation of atrial fibrillation: accuracy of a novel modality in comparison with multislice computed tomography Hear Rhythm 5 1651 1657 10.1016/j.hrthm.2008.09.011
    • (2008) Hear Rhythm , vol.5 , pp. 1651-1657
    • Nolker, G.1    Gutleben, K.J.2    Marschang, H.3
  • 6
    • 70349854894 scopus 로고    scopus 로고
    • Flat-detector computed tomography in diagnostic and interventional neuroradiology
    • 19727642 10.1007/s00117-009-1861-8 1:STN:280:DC%2BD1MnktVKktA%3D%3D
    • T Struffert A Doerfler 2009 Flat-detector computed tomography in diagnostic and interventional neuroradiology Radiologe 49 820 829 19727642 10.1007/s00117-009-1861-8 1:STN:280:DC%2BD1MnktVKktA%3D%3D
    • (2009) Radiologe , vol.49 , pp. 820-829
    • Struffert, T.1    Doerfler, A.2
  • 7
    • 59949097845 scopus 로고    scopus 로고
    • Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: Results in 44 cases
    • 18813932 10.1007/s00330-008-1183-7
    • T Struffert G Richter T Engelhorn, et al. 2009 Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases Eur Radiol 19 3 619 625 18813932 10.1007/s00330-008-1183-7
    • (2009) Eur Radiol , vol.19 , Issue.3 , pp. 619-625
    • Struffert, T.1    Richter, G.2    Engelhorn, T.3
  • 8
    • 77953176260 scopus 로고    scopus 로고
    • Transapical aortic valve implantation in 100 consecutive patients: Comparison to propensity-matched conventional aortic valve replacement
    • 20233788 10.1093/eurheartj/ehq060
    • T Walther G Schuler MA Borger, et al. 2010 Transapical aortic valve implantation in 100 consecutive patients: comparison to propensity-matched conventional aortic valve replacement Eur Heart J 31 1398 1403 20233788 10.1093/eurheartj/ehq060
    • (2010) Eur Heart J , vol.31 , pp. 1398-1403
    • Walther, T.1    Schuler, G.2    Borger, M.A.3
  • 9
    • 78249284009 scopus 로고    scopus 로고
    • Use of angiographic CT imaging in the cardiac catheterization laboratory for congenital heart disease
    • 21071003 10.1016/j.jcmg.2010.09.011
    • AC Glatz X Zhu MJ Gillespie BD Hanna JJ Rome 2010 Use of angiographic CT imaging in the cardiac catheterization laboratory for congenital heart disease JACC Cardiovasc Imaging 3 1149 1157 21071003 10.1016/j.jcmg.2010.09.011
    • (2010) JACC Cardiovasc Imaging , vol.3 , pp. 1149-1157
    • Glatz, A.C.1    Zhu, X.2    Gillespie, M.J.3    Hanna, B.D.4    Rome, J.J.5
  • 10
    • 70349866647 scopus 로고    scopus 로고
    • Basic principles of flat detector computed tomography (FD-CT)
    • 19701623 10.1007/s00117-009-1860-9 1:STN:280:DC%2BD1MnivVWqsg%3D%3D
    • Y Kyriakou T Struffert A Dorfler WA Kalender 2009 Basic principles of flat detector computed tomography (FD-CT) Radiologe 49 811 819 19701623 10.1007/s00117-009-1860-9 1:STN:280:DC%2BD1MnivVWqsg%3D%3D
    • (2009) Radiologe , vol.49 , pp. 811-819
    • Kyriakou, Y.1    Struffert, T.2    Dorfler, A.3    Kalender, W.A.4
  • 11
    • 47649099051 scopus 로고    scopus 로고
    • Concepts for dose determination in flat-detector CT
    • DOI 10.1088/0031-9155/53/13/011, PII S0031915508731658
    • Y Kyriakou P Deak O Langner WA Kalender 2008 Concepts for dose determination in flat-detector CT Phys Med Biol 53 3551 3566 18552416 10.1088/0031-9155/53/13/011 (Pubitemid 352020040)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.13 , pp. 3551-3566
    • Kyriakou, Y.1    Deak, P.2    Langner, O.3    Kalender, W.A.4
  • 12
    • 0019485556 scopus 로고
    • A method for describing the doses delivered by transmission X-ray computed tomography
    • DOI 10.1118/1.594995
    • TB Shope RM Gagne GC Johnson 1981 A method for describing the doses delivered by transmission x-ray computed tomography Med Phys 8 488 495 7322067 10.1118/1.594995 1:CAS:528:DyaL3MXks12lt7k%3D (Pubitemid 11122522)
    • (1981) Medical Physics , vol.8 , Issue.4 , pp. 488-495
    • Shope, T.B.1    Gagne, R.M.2    Johnson, G.C.3
  • 13
    • 33845328849 scopus 로고    scopus 로고
    • Dose and image quality for a cone-beam C-arm CT system
    • DOI 10.1118/1.2370508, 013612MPH
    • R Fahrig R Dixon T Payne RL Morin A Ganguly N Strobel 2006 Dose and image quality for a cone-beam C-arm CT system Med Phys 33 4541 4550 17278805 10.1118/1.2370508 (Pubitemid 44868090)
    • (2006) Medical Physics , vol.33 , Issue.12 , pp. 4541-4550
    • Fahrig, R.1    Dixon, R.2    Payne, T.3    Morin, R.L.4    Ganguly, A.5    Strobel, N.6
  • 14
    • 77953612587 scopus 로고    scopus 로고
    • Utility of computed tomographic angiography in the pre-operative planning for initial and repeat congenital cardiovascular surgery
    • 20346198 10.1017/S1047951109990904
    • AR Ellis D Mulvihill SM Bradley AM Hlavacek 2010 Utility of computed tomographic angiography in the pre-operative planning for initial and repeat congenital cardiovascular surgery Cardiol Young 20 262 268 20346198 10.1017/S1047951109990904
    • (2010) Cardiol Young , vol.20 , pp. 262-268
    • Ellis, A.R.1    Mulvihill, D.2    Bradley, S.M.3    Hlavacek, A.M.4
  • 15
    • 14944343475 scopus 로고    scopus 로고
    • A review of the complementary information available with cardiac magnetic resonance imaging and multi-slice computed tomography (CT) during the study of congenital heart disease
    • DOI 10.1007/s10554-004-7021-3
    • MM Samyn 2004 A review of the complementary information available with cardiac magnetic resonance imaging and multi-slice computed tomography (CT) during the study of congenital heart disease Int J Cardiovasc Imaging 20 569 578 15856644 10.1007/s10554-004-7021-3 (Pubitemid 40372373)
    • (2004) International Journal of Cardiovascular Imaging , vol.20 , Issue.6 , pp. 569-578
    • Samyn, M.M.1
  • 16
    • 79954611497 scopus 로고    scopus 로고
    • Cerebral blood volume imaging by flat detector computed tomography in comparison to conventional multislice perfusion CT
    • 20857117 10.1007/s00330-010-1957-6
    • T Struffert Y Deuerling-Zheng S Kloska, et al. 2010 Cerebral blood volume imaging by flat detector computed tomography in comparison to conventional multislice perfusion CT Eur Radiol 21 882 889 20857117 10.1007/s00330-010-1957-6
    • (2010) Eur Radiol , vol.21 , pp. 882-889
    • Struffert, T.1    Deuerling-Zheng, Y.2    Kloska, S.3
  • 17
    • 77950245851 scopus 로고    scopus 로고
    • Imaging of cochlear implant electrode array with flat-detector CT and conventional multislice CT: Comparison of image quality and radiation dose
    • 19883180 10.3109/00016480903292700
    • T Struffert V Hertel Y Kyriakou, et al. 2010 Imaging of cochlear implant electrode array with flat-detector CT and conventional multislice CT: comparison of image quality and radiation dose Acta Otolaryngol 130 443 452 19883180 10.3109/00016480903292700
    • (2010) Acta Otolaryngol , vol.130 , pp. 443-452
    • Struffert, T.1    Hertel, V.2    Kyriakou, Y.3
  • 18
    • 77953678690 scopus 로고    scopus 로고
    • Rapid pacing rotational angiography with three-dimensional reconstruction: Use and benefits in structural heart disease interventions
    • 20449932 10.4244/EIJV5I2A38
    • S Noble J Miro G Yong R Bonan JC Tardif R Ibrahim 2009 Rapid pacing rotational angiography with three-dimensional reconstruction: use and benefits in structural heart disease interventions EuroIntervention 5 244 249 20449932 10.4244/EIJV5I2A38
    • (2009) EuroIntervention , vol.5 , pp. 244-249
    • Noble, S.1    Miro, J.2    Yong, G.3    Bonan, R.4    Tardif, J.C.5    Ibrahim, R.6
  • 19
    • 79955402874 scopus 로고    scopus 로고
    • Three-dimensional computed tomography in the cardiac catheterization laboratory
    • 10.1002/ccd.22740
    • A Krishnaswamy EM Tuzcu SR Kapadia 2010 Three-dimensional computed tomography in the cardiac catheterization laboratory Catheter Cardiovasc Interv 77 860 865 10.1002/ccd.22740
    • (2010) Catheter Cardiovasc Interv , vol.77 , pp. 860-865
    • Krishnaswamy, A.1    Tuzcu, E.M.2    Kapadia, S.R.3
  • 20
    • 2342645989 scopus 로고    scopus 로고
    • Dynamic three-dimensional reconstruction and modeling of cardiovascular anatomy in children with congenital heart disease using biplane angiography
    • C Lanning SY Chen A Hansgen D Chang KC Chan R Shandas 2004 Dynamic three-dimensional reconstruction and modeling of cardiovascular anatomy in children with congenital heart disease using biplane angiography Biomed Sci Instrum 40 200 205 15133958 (Pubitemid 38595955)
    • (2004) Biomedical Sciences Instrumentation , vol.40 , pp. 200-205
    • Lanning, C.1    Chen, S.-Y.J.2    Hansgen, A.3    Chang, D.4    Chan, K.C.5    Shandas, R.6
  • 21
    • 76349094438 scopus 로고    scopus 로고
    • Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition
    • 19897497 10.1093/eurheartj/ehp470
    • S Achenbach M Marwan D Ropers, et al. 2010 Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition Eur Heart J 31 340 346 19897497 10.1093/eurheartj/ehp470
    • (2010) Eur Heart J , vol.31 , pp. 340-346
    • Achenbach, S.1    Marwan, M.2    Ropers, D.3
  • 22
    • 73949094933 scopus 로고    scopus 로고
    • High-pitch electrocardiogram-triggered computed tomography of the chest: Initial results
    • 19809339 10.1097/RLI.0b013e3181b9df7e
    • M Lell F Hinkmann K Anders, et al. 2009 High-pitch electrocardiogram- triggered computed tomography of the chest: initial results Invest Radiol 44 728 733 19809339 10.1097/RLI.0b013e3181b9df7e
    • (2009) Invest Radiol , vol.44 , pp. 728-733
    • Lell, M.1    Hinkmann, F.2    Anders, K.3
  • 23
    • 78751615956 scopus 로고    scopus 로고
    • High-pitch spiral computed tomography: Effect on image quality and radiation dose in pediatric chest computed tomography
    • 20856124 10.1097/RLI.0b013e3181f33b1d
    • MM Lell M May P Deak, et al. 2011 High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography Invest Radiol 46 116 123 20856124 10.1097/RLI.0b013e3181f33b1d
    • (2011) Invest Radiol , vol.46 , pp. 116-123
    • Lell, M.M.1    May, M.2    Deak, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.