메뉴 건너뛰기




Volumn 51, Issue 5 II, 2004, Pages 2649-2653

Correction for crosstalk contaminations in dual radionuclide 99mTc and 123I images using artificial neural network

Author keywords

Artificial neural network (ANN); Crosstalk contamination; Dual radionuclide imaging

Indexed keywords

COMPUTER SIMULATION; IMAGING TECHNIQUES; MONTE CARLO METHODS; NEURAL NETWORKS; PHOTOSENSITIVE GLASS; RADIOISOTOPES;

EID: 8344290564     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2004.834826     Document Type: Article
Times cited : (13)

References (14)
  • 1
    • 0036816148 scopus 로고    scopus 로고
    • Quantitative simultaneous 99mTc/123I SPECT: Design study and validation with Monte Carlo simulation and physical acquisitions
    • G. E. Fakhri, P. Maksud, M. F. Kijewski, R. E. Zimmerman, and S. C. Moore, "Quantitative simultaneous 99mTc/123I SPECT: Design study and validation with Monte Carlo simulation and physical acquisitions," IEEE Trans. Nucl. Sci., vol. 49, pp. 2315-2321, 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , pp. 2315-2321
    • Fakhri, G.E.1    Maksud, P.2    Kijewski, M.F.3    Zimmerman, R.E.4    Moore, S.C.5
  • 2
    • 0035128888 scopus 로고    scopus 로고
    • Absolute activity quantitation in simultaneous 123I/99mTc brain SPECT
    • G. E. Fakhri, S. C. Moore, P. Maksud, A. Aurengo, and M. F. Kijewski, "Absolute activity quantitation in simultaneous 123I/99mTc brain SPECT," J. Nucl. Med., vol. 42, pp. 300-308, 2001.
    • (2001) J. Nucl. Med. , vol.42 , pp. 300-308
    • Fakhri, G.E.1    Moore, S.C.2    Maksud, P.3    Aurengo, A.4    Kijewski, M.F.5
  • 3
    • 0034244711 scopus 로고    scopus 로고
    • Scatter and cross-talk corrections in simultaneous Tc-99m/I-123 brain SPECT using constrained factor analysis and artificial neural network
    • G. E. Fakhri, P. Maksud, M. F. Kijewski, M. O. Habert, A. Todd-Pokropek, A. Aurengo, and S. C. Moore, "Scatter and cross-talk corrections in simultaneous Tc-99m/I-123 brain SPECT using constrained factor analysis and artificial neural network," IEEE Trans. Nucl. Sci., vol. 47, pp. 1573-1580, 2000.
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , pp. 1573-1580
    • Fakhri, G.E.1    Maksud, P.2    Kijewski, M.F.3    Habert, M.O.4    Todd-Pokropek, A.5    Aurengo, A.6    Moore, S.C.7
  • 4
    • 0029800364 scopus 로고    scopus 로고
    • Simultaneous dual-radionuclide imaging: Are the images trustworthy
    • J. M. Links, "Simultaneous dual-radionuclide imaging: Are the images trustworthy," Eur. J Nucl. Med., vol. 23, pp. 1289-1291, 1996.
    • (1996) Eur. J Nucl. Med. , vol.23 , pp. 1289-1291
    • Links, J.M.1
  • 5
    • 0026540008 scopus 로고
    • Dual isotope brain SPECT imaging with technetium-99m and iodine-123: Validation by phantom studies
    • M. D. Devous Sr, J. L. Lowe, and J. K. Payne, "Dual isotope brain SPECT imaging with technetium-99m and iodine-123: Validation by phantom studies," J. Nucl. Med., vol. 33, pp. 2030-2035, 1992.
    • (1992) J. Nucl. Med. , vol.33 , pp. 2030-2035
    • Devous Sr., M.D.1    Lowe, J.L.2    Payne, J.K.3
  • 6
    • 0028276762 scopus 로고
    • Feasibility of dual radionuclide brain imaging with I-123 and Tc-99m
    • M. Ivanovic, D. A. Weber, S. Loncaric, and D. Franceschi, "Feasibility of dual radionuclide brain imaging with I-123 and Tc-99m," Med. Phys., vol. 21, pp. 667-74, 1994.
    • (1994) Med. Phys. , vol.21 , pp. 667-674
    • Ivanovic, M.1    Weber, D.A.2    Loncaric, S.3    Franceschi, D.4
  • 7
    • 22644450373 scopus 로고    scopus 로고
    • Spectral factor analysis for multi-isotope imaging in nuclear medicine
    • A. Kuba et al., Eds
    • I. Buvat, S. Hapdey, H. Benali, A. Todd-Pokropek, and R. D. Paola et al., "Spectral factor analysis for multi-isotope imaging in nuclear medicine," in IPMI'99, vol. LNCS 1613, A. Kuba et al., Eds., 1999, pp. 442-447.
    • (1999) IPMI'99 , vol.LNCS 1613 , pp. 442-447
    • Buvat, I.1    Hapdey, S.2    Benali, H.3    Todd-Pokropek, A.4    Paola, R.D.5
  • 8
    • 0142179059 scopus 로고    scopus 로고
    • Validation and evaluation of model-based cross-talk compensation method in simultaneous 99mTc stress and 201Tl rest myocardial perfusion SPECT
    • X. Song, E. C. Frey, W. T. Wang, Y. Du, and B. M. W. Tsui, "Validation and evaluation of model-based cross-talk compensation method in simultaneous 99mTc stress and 201Tl rest myocardial perfusion SPECT," in IEEE TNS Conf. Rec. 2002.
    • (2002) IEEE TNS Conf. Rec.
    • Song, X.1    Frey, E.C.2    Wang, W.T.3    Du, Y.4    Tsui, B.M.W.5
  • 9
    • 0005424540 scopus 로고    scopus 로고
    • Scatter correction in multinuclide data acquisition by means of a neural network
    • Seattle, WA
    • A. Matsunaga and K. Ogawa, "Scatter correction in multinuclide data acquisition by means of a neural network," in Proc. NSS/MIC, Seattle, WA, 1999.
    • (1999) Proc. NSS/MIC
    • Matsunaga, A.1    Ogawa, K.2
  • 10
    • 0028146615 scopus 로고
    • A method of simultaneous dual-radionuclide cardiac imaging with technetium 99m and thallium 201. I: Analysis of interradionuclide crossover and validation in phantoms
    • H. Weinstein, M. A. King, C. P. Reinhardt, B. A. McSherry, and J. A. Leppo, "A method of simultaneous dual-radionuclide cardiac imaging with technetium 99m and thallium 201. I: Analysis of interradionuclide crossover and validation in phantoms," J. Nucl. Cardiol., vol. 1, pp. 39-51, 1994.
    • (1994) J. Nucl. Cardiol. , vol.1 , pp. 39-51
    • Weinstein, H.1    King, M.A.2    Reinhardt, C.P.3    McSherry, B.A.4    Leppo, J.A.5
  • 11
    • 0027644794 scopus 로고
    • Accurate scatter compensation using neural networks in radionuclide imaging
    • K. Ogawa and N. Nishizaki, "Accurate scatter compensation using neural networks in radionuclide imaging," IEEE Trans. Nucl. Sci., vol. 40, pp. 1020-1025, 1993.
    • (1993) IEEE Trans. Nucl. Sci. , vol.40 , pp. 1020-1025
    • Ogawa, K.1    Nishizaki, N.2
  • 13
    • 0028218858 scopus 로고
    • Comparative feasibility of separate or simultaneous rest thallium-201/stress technetium-99m sestamibi dual-radionuclide myocardial perfusion SPECT
    • H. Kiat et al., "Comparative feasibility of separate or simultaneous rest thallium-201/stress technetium-99m sestamibi dual-radionuclide myocardial perfusion SPECT," J. Nucl. Med., vol. 35, pp. 542-548, 1994.
    • (1994) J. Nucl. Med. , vol.35 , pp. 542-548
    • Kiat, H.1
  • 14
    • 8344225083 scopus 로고    scopus 로고
    • Dual-isotope SPECT brain imaging using 123-I and 99m-Tc for two independent activation tasks
    • G. Zubal, S. Nishizawa, Y. Fujibayashi, and Y. Yonekura, "Dual-isotope SPECT brain imaging using 123-I and 99m-Tc for two independent activation tasks," J. Nucl. Med., vol. 43, no. Suppl., pp. 200P-200P, 2002.
    • (2002) J. Nucl. Med. , vol.43 , Issue.SUPPL.
    • Zubal, G.1    Nishizawa, S.2    Fujibayashi, Y.3    Yonekura, Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.