메뉴 건너뛰기




Volumn 35, Issue 22, 2011, Pages 41-44

Cause and countermeasure analysis on wind turbines' trip-off from grid

Author keywords

Low voltage ride though; Reactive power compensation; Security and stability; Trip off from grid; Voltage control; Wind power; Wind turbines

Indexed keywords

IMPROVEMENT METHODS; LOW VOLTAGES; OPERATION MANAGEMENT; REACTIVE POWER COMPENSATION; SAFETY REQUIREMENTS; SECURITY AND STABILITY; STABLE OPERATION; TECHNICAL PERFORMANCE; TRIP-OFF FROM GRID; WIND POWER INDUSTRY;

EID: 83255175062     PISSN: 10001026     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (67)

References (5)
  • 1
    • 35348892614 scopus 로고    scopus 로고
    • Wind generation integration & operation-technical challenges/issues
    • June 18-22, Montreal, QUE, Canada
    • HOCHHEIMER J. Wind generation integration & operation-technical challenges/issues[C]// Proceedings of IEEE Power Engineering Society General Meeting, June 18-22, 2006, Montreal, QUE, Canada: 1-6.
    • (2006) Proceedings of IEEE Power Engineering Society General Meeting , pp. 1-6
    • Hochheimer, J.1
  • 2
    • 39749142476 scopus 로고    scopus 로고
    • Study on impact of wind power integration on power system
    • CHI Yongning, LIU Yanhua, WANG Weisheng, et al. Study on impact of wind power integration on power system[J]. Power System Technology, 2007, 33(3): 77-81.
    • (2007) Power System Technology , vol.33 , Issue.3 , pp. 77-81
    • Chi, Y.1    Liu, Y.2    Wang, W.3
  • 3
    • 70349174795 scopus 로고    scopus 로고
    • Recent wind power integration study in China
    • DAI Huizhu, WANG Weisheng, CHI Yongning. Recent wind power integration study in China[J]. Power System Technology, 2007, 33(20): 16-23.
    • (2007) Power System Technology , vol.33 , Issue.20 , pp. 16-23
    • Dai, H.1    Wang, W.2    Chi, Y.3
  • 4
    • 16644367195 scopus 로고    scopus 로고
    • Studies on wind farm integration into power system
    • LEI Yazhou. Studies on wind farm integration into power system[J]. Automation of Electric Power Systems, 2003, 27(8): 84-89.
    • (2003) Automation of Electric Power Systems , vol.27 , Issue.8 , pp. 84-89
    • Lei, Y.1
  • 5
    • 83255168084 scopus 로고    scopus 로고
    • Analysis on the integration and operation of the first wind farm of mega kilowatt in Jing-Jin-Tang grid
    • LIANG Yuzhi, LI Qunju, WANG Peiwen. Analysis on the integration and operation of the first wind farm of mega kilowatt in Jing-Jin-Tang grid[J]. Electric Power, 2010, 43(6): 1-4.
    • (2010) Electric Power , vol.43 , Issue.6 , pp. 1-4
    • Liang, Y.1    Li, Q.2    Wang, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.