메뉴 건너뛰기




Volumn , Issue , 2011, Pages

Quantitative comparison of 4D MRI flow measurements to 3D computational fluid dynamics simulation of cerebrospinal fluid movement in the spinal subarachnoid space

Author keywords

[No Author keywords available]

Indexed keywords

CEREBRO SPINAL FLUIDS; CFD ANALYSIS; COMPLEX FLOW; COMPUTATIONAL FLUID DYNAMICS SIMULATIONS; IN-VIVO MEASUREMENT; MEASUREMENT TECHNOLOGIES; NEUROLOGICAL SYMPTOMS; PRESSURE FIELD; QUANTITATIVE COMPARISON; SPINAL CANALS; SPINAL SEGMENTS; SPINAL STENOSIS; SUBARACHNOID SPACES; SUPERIOR SAGITTAL SINUS;

EID: 83255165691     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IWBE.2011.6079027     Document Type: Conference Paper
Times cited : (5)

References (12)
  • 1
    • 0023223706 scopus 로고
    • Human-Brain Motion and Cerebrospinal-Fluid Circulation Demonstrated with Mr Velocity Imaging
    • Jun
    • D. A. Feinberg and A. S. Mark, "Human-Brain Motion and Cerebrospinal-Fluid Circulation Demonstrated with Mr Velocity Imaging," Radiology, vol. 163, pp. 793-799, Jun 1987.
    • (1987) Radiology , vol.163 , pp. 793-799
    • Feinberg, D.A.1    Mark, A.S.2
  • 2
    • 80052654098 scopus 로고    scopus 로고
    • Magnetic resonance 4D flow characteristics of cerebrospinal fluid at the craniocervical junction and the cervical spinal canal
    • Aug
    • A. C. Bunck, et al., "Magnetic resonance 4D flow characteristics of cerebrospinal fluid at the craniocervical junction and the cervical spinal canal," European Radiology, vol. 21, pp. 1788-96, Aug 2011.
    • (2011) European Radiology , vol.21 , pp. 1788-1796
    • Bunck, A.C.1
  • 3
    • 7044227660 scopus 로고    scopus 로고
    • Foramen magnum cerebrospinal fluid flow characteristics in children with Chiari I malformation before and after craniocervical decompression
    • Nov
    • B. J. Iskandar, et al., "Foramen magnum cerebrospinal fluid flow characteristics in children with Chiari I malformation before and after craniocervical decompression," Journal of Neurosurgery, vol. 101, pp. 169-178, Nov 2004.
    • (2004) Journal of Neurosurgery , vol.101 , pp. 169-178
    • Iskandar, B.J.1
  • 4
    • 24944494967 scopus 로고    scopus 로고
    • Magnetic resonance imaging-based measurements of cerebrospinal fluid and blood flow as indicators of intracranial compliance in patients with Chiari malformation
    • N. Alperin, et al., "Magnetic resonance imaging-based measurements of cerebrospinal fluid and blood flow as indicators of intracranial compliance in patients with Chiari malformation," Journal of Neurosurgery, vol. 103, pp. 46-52, Jul 2005. (Pubitemid 43193933)
    • (2005) Journal of Neurosurgery , vol.103 , Issue.1 , pp. 46-52
    • Alperin, N.1    Sivaramakrishnan, A.2    Lichtor, T.3
  • 5
    • 77955642553 scopus 로고    scopus 로고
    • Cerebrospinal fluid dynamics in the human cranial subarachnoid space: An overlooked mediator of cerebral disease. I. Computational model
    • Aug 6
    • V. Kurtcuoglu, et al., "Cerebrospinal fluid dynamics in the human cranial subarachnoid space: an overlooked mediator of cerebral disease. I. Computational model," Journal of the Royal Society Interface, vol. 7, pp. 1195-1204, Aug 6 2010.
    • (2010) Journal of the Royal Society Interface , vol.7 , pp. 1195-1204
    • Kurtcuoglu, V.1
  • 6
    • 63449097077 scopus 로고    scopus 로고
    • Three-Dimensional Computational Modeling of Subject-Specific Cerebrospinal Fluid Flow in the Subarachnoid Space
    • Feb
    • S. Gupta, et al., "Three-Dimensional Computational Modeling of Subject-Specific Cerebrospinal Fluid Flow in the Subarachnoid Space," Journal of Biomechanical Engineering-Transactions of the Asme, vol. 131, pp. -, Feb 2009.
    • (2009) Journal of Biomechanical Engineering-Transactions of the Asme , vol.131
    • Gupta, S.1
  • 7
    • 33947592243 scopus 로고    scopus 로고
    • Computational investigation of subject-specific cerebrospinal fluid flow in the third ventricle and aqueduct of Sylvius
    • DOI 10.1016/j.jbiomech.2006.05.031, PII S0021929006002156
    • V. Kurtcuoglu, et al., "Computational investigation of subject-specific cerebrospinal fluid flow in the third ventricle and aqueduct of Sylvius," Journal of Biomechanics, vol. 40, pp. 1235-1245, 2007. (Pubitemid 46483463)
    • (2007) Journal of Biomechanics , vol.40 , Issue.6 , pp. 1235-1245
    • Kurtcuoglu, V.1    Soellinger, M.2    Summers, P.3    Boomsma, K.4    Poulikakos, D.5    Boesiger, P.6    Ventikos, Y.7
  • 8
    • 18644362790 scopus 로고    scopus 로고
    • Computational modeling of the mechanical behavior of the cerebrospinal fluid system
    • DOI 10.1115/1.1865191
    • V. Kurtcuoglu, et al., "Computational modeling of the mechanical behavior of the cerebrospinal fluid system," Journal of Biomechanical Engineering-Transactions of the Asme, vol. 127, pp. 264-269, Apr 2005. (Pubitemid 40663969)
    • (2005) Journal of Biomechanical Engineering , vol.127 , Issue.2 , pp. 264-269
    • Kurtcuoglu, V.1    Poulikakos, D.2    Ventikos, Y.3
  • 9
    • 0035089444 scopus 로고    scopus 로고
    • Hydrodynamic modeling of cerebrospinal fluid motion within the spinal cavity
    • DOI 10.1115/1.1336144
    • F. Loth, et al., "Hydrodynamic modeling of cerebrospinal fluid motion within the spinal cavity," Journal of Biomechanical Engineering-Transactions of the Asme, vol. 123, pp. 71-79, Feb 2001. (Pubitemid 32202582)
    • (2001) Journal of Biomechanical Engineering , vol.123 , Issue.1 , pp. 71-79
    • Loth, F.1    Yardimci, M.A.2    Alperin, N.3
  • 11
    • 70349632621 scopus 로고    scopus 로고
    • Time-resolved three-dimensional (3D) phase-contrast (PC) balanced steady-state free precession (bSSFP)
    • Oct
    • F. Santini, et al., "Time-resolved three-dimensional (3D) phase-contrast (PC) balanced steady-state free precession (bSSFP)," Magn Reson Med, vol. 62, pp. 966-74, Oct 2009.
    • (2009) Magn Reson Med , vol.62 , pp. 966-974
    • Santini, F.1
  • 12
    • 33744930583 scopus 로고    scopus 로고
    • User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability
    • Jul 1
    • P. A. Yushkevich, et al., "User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability," Neuroimage, vol. 31, pp. 1116-1128, Jul 1 2006.
    • (2006) Neuroimage , vol.31 , pp. 1116-1128
    • Yushkevich, P.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.