메뉴 건너뛰기




Volumn 52, Issue 8, 2011, Pages 889-893

Accuracy of CT angiography in the assessment of the circle of Willis: Comparison of volume-rendered images and digital subtraction angiography

Author keywords

Anatomic variation; Brain; Circle of Willis; CT angiography; Digital subtraction angiography; Vascular

Indexed keywords

ANATOMIC VARIATION; CIRCLE OF WILLIS; CT ANGIOGRAPHY; DIGITAL SUBTRACTION ANGIOGRAPHY; VASCULAR;

EID: 83155167717     PISSN: 02841851     EISSN: 16000455     Source Type: Journal    
DOI: 10.1258/ar.2011.110223     Document Type: Article
Times cited : (32)

References (26)
  • 2
    • 0028198859 scopus 로고
    • The anatomy of the posterior communicating artery as a risk factor for ischemic cerebral infarction
    • Schomer DF, Marks MP, Steinberg GK, et al. The anatomy of the posterior communicating artery as a risk factor for ischemic cerebral infarction. N Engl J Med 1994;330:1565-70
    • (1994) N Engl J Med , vol.330 , pp. 1565-1570
    • Schomer, D.F.1    Marks, M.P.2    Steinberg, G.K.3
  • 3
    • 0031982341 scopus 로고    scopus 로고
    • Circle of Willis: Morphologic variation on three-dimensional time-of-flight MR angiograms
    • Krabbe-Hartkamp MJ, van der Grond J, de Leeuw FE, et al. Circle of Willis: morphologic variation on three-dimensional time-of-flight MR angiograms. Radiology 1998;207:103-11
    • (1998) Radiology , vol.207 , pp. 103-111
    • Krabbe-Hartkamp, M.J.1    Van Der Grond, J.2    De Leeuw, F.E.3
  • 4
    • 33947194470 scopus 로고    scopus 로고
    • Anatomic variations in the circle of Willis in patients with symptomatic carotid artery stenosis assessed with multidetector row CT angiography
    • Waaijer A, van Leeuwen MS, van der Worp HB, et al. Anatomic variations in the circle of Willis in patients with symptomatic carotid artery stenosis assessed with multidetector row CT angiography. Cerebrovasc Dis 2007;23:267-74
    • (2007) Cerebrovasc Dis , vol.23 , pp. 267-274
    • Waaijer, A.1    Van Leeuwen, M.S.2    Van Der Worp, H.B.3
  • 5
    • 4544346164 scopus 로고    scopus 로고
    • Accuracy of CT angiography in the assessment of a fetal origin of the posterior cerebral artery
    • Van der Lugt A, Buter TC, Govaere F, et al. Accuracy of CT angiography in the assessment of a fetal origin of the posterior cerebral artery. Eur Radiol 2004;14:1627-33
    • (2004) Eur Radiol , vol.14 , pp. 1627-1633
    • Van Der Lugt, A.1    Buter, T.C.2    Govaere, F.3
  • 6
    • 0029773632 scopus 로고    scopus 로고
    • Complications of diagnostic cerebral angiography and tips on avoidance
    • Pryor JC, Setton A, Nelson PK, et al. Complications of diagnostic cerebral angiography and tips on avoidance. Neuroimaging Clin N Am 1996;6:751-8
    • (1996) Neuroimaging Clin N Am , vol.6 , pp. 751-758
    • Pryor, J.C.1    Setton, A.2    Nelson, P.K.3
  • 7
    • 0032961565 scopus 로고    scopus 로고
    • Risk of cerebral angiography in patients with subarachnoid hemorrhage, cerebral aneurysm", arteriovenous malformation: A meta-analysis
    • Cloft HJ, Joseph GJ, Dion JE. Risk of cerebral angiography in patients with subarachnoid hemorrhage, cerebral aneurysm", arteriovenous malformation: a meta-analysis. Stroke 1999;30:317-20
    • (1999) Stroke , vol.30 , pp. 317-320
    • Cloft, H.J.1    Joseph, G.J.2    Dion, J.E.3
  • 8
    • 33846432026 scopus 로고    scopus 로고
    • Detection and characterization of intracranial aneurysms with 16-channel multidetector row CT angiography: A prospective comparison of volume-rendered images and digital subtraction angiography
    • Yoon DY, Lim KJ, Choi CS, et al. Detection and characterization of intracranial aneurysms with 16-channel multidetector row CT angiography: a prospective comparison of volume-rendered images and digital subtraction angiography. Am J Neuroradiol 2007;28:60-7
    • (2007) Am J Neuroradiol , vol.28 , pp. 60-67
    • Yoon, D.Y.1    Lim, K.J.2    Choi, C.S.3
  • 9
    • 33645736339 scopus 로고    scopus 로고
    • Multidetector-row CT angiography of cerebral vasospasm after aneurysmal subarachnoid hemorrhage: Comparison of volume-rendered images and digital subtraction angiography
    • Yoon DY, Choi CS, Kim KH, et al. Multidetector-row CT angiography of cerebral vasospasm after aneurysmal subarachnoid hemorrhage: comparison of volume-rendered images and digital subtraction angiography. Am J Neuroradiol 2006;27:370-7
    • (2006) Am J Neuroradiol , vol.27 , pp. 370-377
    • Yoon, D.Y.1    Choi, C.S.2    Kim, K.H.3
  • 10
    • 0036155748 scopus 로고    scopus 로고
    • Prospective evaluation for suspected stenoocclusive disease of the intracranial artery: Combined MR angiography and CT angiography compared with digital subtraction angiography
    • Hirai T, Korogi Y, Ono K, et al. Prospective evaluation for suspected stenoocclusive disease of the intracranial artery: combined MR angiography and CT angiography compared with digital subtraction angiography. Am J Neuroradiol 2002;23:93-101
    • (2002) Am J Neuroradiol , vol.23 , pp. 93-101
    • Hirai, T.1    Korogi, Y.2    Ono, K.3
  • 11
    • 0344641914 scopus 로고    scopus 로고
    • Intracranial stenoocclusive disease: Double-detector helical CT angiography versus digital subtraction angiography
    • Skutta B, Fürst G, Eilers J, et al. Intracranial stenoocclusive disease: double-detector helical CT angiography versus digital subtraction angiography. Am J Neuroradiol 1999;20:791-9
    • (1999) Am J Neuroradiol , vol.20 , pp. 791-799
    • Skutta, B.1    Fürst, G.2    Eilers, J.3
  • 12
    • 0002038677 scopus 로고
    • The circle of willis: An examination of 700 specimens
    • Fawcett E, Blachford JV. The circle of willis: an examination of 700 specimens. J Anat Physiol 1905;40:63-70
    • (1905) J Anat Physiol , vol.40 , pp. 63-70
    • Fawcett, E.1    Blachford, J.V.2
  • 13
    • 73649191389 scopus 로고
    • Variation in form of circle of Willis. The relation of the variations to collateral circulation: Anatomic analysis
    • Riggs HE, Rupp C. Variation in form of circle of Willis. The relation of the variations to collateral circulation: anatomic analysis. Arch Neurol 1963;8:24-30
    • (1963) Arch Neurol , vol.8 , pp. 24-30
    • Riggs, H.E.1    Rupp, C.2
  • 14
    • 0025015618 scopus 로고
    • Haemodynamic aspects of clinical cerebral angiography: Concurrent two vessel monitoring using transcranial Doppler ultrasound
    • Nornes H, Sorteberg W, Nakstad P, et al. Haemodynamic aspects of clinical cerebral angiography: concurrent two vessel monitoring using transcranial Doppler ultrasound. Acta Neurochir (Wien) 1990;105:89-97
    • (1990) Acta Neurochir (Wien) , vol.105 , pp. 89-97
    • Nornes, H.1    Sorteberg, W.2    Nakstad, P.3
  • 15
    • 0028215375 scopus 로고
    • Magnetic resonance angiography (MRA) of the circle of Willis: A prospective comparison with conventional angiography in 54 subjects
    • Patrux B, Laissy JP, Jouini S, et al. Magnetic resonance angiography (MRA) of the circle of Willis: a prospective comparison with conventional angiography in 54 subjects. Neuroradiology 1994;36:193-7
    • (1994) Neuroradiology , vol.36 , pp. 193-197
    • Patrux, B.1    Laissy, J.P.2    Jouini, S.3
  • 16
    • 0028904537 scopus 로고
    • Circle of Willis: Evaluation with spiral CT angiography, MR angiography, and conventional angiography
    • Katz DA, Marks MP, Napel SA, et al. Circle of Willis: evaluation with spiral CT angiography, MR angiography, and conventional angiography. Radiology 1995;195:445-9
    • (1995) Radiology , vol.195 , pp. 445-449
    • Katz, D.A.1    Marks, M.P.2    Napel, S.A.3
  • 17
    • 0025105108 scopus 로고
    • Magnetic resonance imaging of flow dynamics in the circle of Willis
    • Edelman RR, Mattle HP, O'Reilly GV, et al. Magnetic resonance imaging of flow dynamics in the circle of Willis. Stroke 1990;21:56-65
    • (1990) Stroke , vol.21 , pp. 56-65
    • Edelman, R.R.1    Mattle, H.P.2    O'Reilly, G.V.3
  • 18
    • 0027465241 scopus 로고
    • Selective MR angiography and intracranial collateral blood flow
    • Fürst G, Steinmetz H, Fischer H, et al. Selective MR angiography and intracranial collateral blood flow. J Comput Assist Tomogr 1993;17:178-83
    • (1993) J Comput Assist Tomogr , vol.17 , pp. 178-183
    • Fürst, G.1    Steinmetz, H.2    Fischer, H.3
  • 19
    • 0029815222 scopus 로고    scopus 로고
    • Anatomic evaluation of the circle of Willis: MR angiography versus intraarterial digital subtraction angiography
    • Stock KW, Wetzel S, Kirsch E, et al. Anatomic evaluation of the circle of Willis: MR angiography versus intraarterial digital subtraction angiography. Am J Neuroradiol 1996;17:1495-9
    • (1996) Am J Neuroradiol , vol.17 , pp. 1495-1499
    • Stock, K.W.1    Wetzel, S.2    Kirsch, E.3
  • 20
    • 44449118566 scopus 로고    scopus 로고
    • Diagnosing cerebral collateral flow patterns: Accuracy of non-invasive testing
    • Hendrikse J, Klijn CJ, van Huffelen AC, et al. Diagnosing cerebral collateral flow patterns: accuracy of non-invasive testing. Cerebrovasc Dis 2008;25:430-7
    • (2008) Cerebrovasc Dis , vol.25 , pp. 430-437
    • Hendrikse, J.1    Klijn, C.J.2    Van Huffelen, A.C.3
  • 21
    • 0029157401 scopus 로고
    • Factors influencing flow induced signal loss in MR angiography: An in vitro study
    • Fürst G, Hofer M, Sitzer M, et al. Factors influencing flow induced signal loss in MR angiography: an in vitro study. J Comput Assist Tomogr 1995;19:692-9
    • (1995) J Comput Assist Tomogr , vol.19 , pp. 692-699
    • Fürst, G.1    Hofer, M.2    Sitzer, M.3
  • 22
    • 0026885407 scopus 로고
    • Mechanisms of flow-induced signal loss in MR angiography
    • Urchuk SN, Plewes DB. Mechanisms of flow-induced signal loss in MR angiography. J Magn Reson Imaging 1992;2:453-62
    • (1992) J Magn Reson Imaging , vol.2 , pp. 453-462
    • Urchuk, S.N.1    Plewes, D.B.2
  • 23
    • 68249141994 scopus 로고    scopus 로고
    • Circle of Willis artery diameters on MR angiography: An Australian reference database
    • El-Barhoun EN, Gledhill SR, Pitman AG. Circle of Willis artery diameters on MR angiography: an Australian reference database. J Med Imaging Radiat Oncol 2009;53:248-60
    • (2009) J Med Imaging Radiat Oncol , vol.53 , pp. 248-260
    • El-Barhoun, E.N.1    Gledhill, S.R.2    Pitman, A.G.3
  • 24
    • 33747344165 scopus 로고    scopus 로고
    • Are the distributions of variations of circle of Willis different in different populations? Results of an anatomical study and review of literature
    • Eftekhar B, Dadmehr M, Ansari S, et al. Are the distributions of variations of circle of Willis different in different populations? Results of an anatomical study and review of literature. BMC Neurol 2006;6:22
    • (2006) BMC Neurol , vol.6 , pp. 22
    • Eftekhar, B.1    Dadmehr, M.2    Ansari, S.3
  • 25
    • 0036820524 scopus 로고    scopus 로고
    • The supratentorial arteries
    • Rhoton AL. The supratentorial arteries. Neurosurgery 2002;51:S53-S120
    • (2002) Neurosurgery , vol.51
    • Rhoton, A.L.1
  • 26
    • 0021873601 scopus 로고
    • Cerebral vasospasm following aneurysmal subarachnoid hemorrhage
    • Kessell NF, Sasaki T, Colohan ART, et al. Cerebral vasospasm following aneurysmal subarachnoid hemorrhage. Stroke 1985;16:562-81
    • (1985) Stroke , vol.16 , pp. 562-581
    • Kessell, N.F.1    Sasaki, T.2    Colohan, A.R.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.