메뉴 건너뛰기




Volumn , Issue , 2006, Pages

Location of single line-to-ground faults on distribution feeders using voltage measurements

Author keywords

Fault Location; Power Distribution; Voltage Measurement

Indexed keywords

ALGORITHM EFFICIENCY; CURRENT PHASORS; DISTRIBUTION FEEDERS; DISTRIBUTION SYSTEMS; FAULT SIMULATION; FEEDER BUS; POWER DISTRIBUTIONS; POWER QUALITY DEVICES; SINGLE LINE-TO-GROUND FAULTS; SOME-BUS; TOPOLOGICAL PARAMETERS; VOLTAGE MAGNITUDE;

EID: 82955225386     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/TDCLA.2006.311592     Document Type: Conference Paper
Times cited : (12)

References (16)
  • 4
    • 0026938292 scopus 로고
    • Fault location techniques for radial and loop transmission systems using digital fault recorded data
    • Oct.
    • A. A. Girgis, and C. M. Fallon, "Fault location techniques for radial and loop transmission systems using digital fault recorded data", IEEE Trans. Power Delivery, vol. 7, pp. 1936-1945, Oct. 1992.
    • (1992) IEEE Trans. Power Delivery , vol.7 , pp. 1936-1945
    • Girgis, A.A.1    Fallon, C.M.2
  • 5
  • 7
    • 0031143411 scopus 로고    scopus 로고
    • New concept in fault location for overhead distribution systems using superimposed components
    • May
    • R. K. Aggarwal, Y. Aslan, and A. T. Johns, "New concept in fault location for overhead distribution systems using superimposed components", IEE Proc. Generation, Transmission and Distribution, vol. 44, pp. 309-316, May 1997.
    • (1997) IEE Proc. Generation, Transmission and Distribution , vol.44 , pp. 309-316
    • Aggarwal, R.K.1    Aslan, Y.2    Johns, A.T.3
  • 8
    • 0031122051 scopus 로고    scopus 로고
    • Automated fault location and diagnosis on electric power distribution feeders
    • Apr.
    • J. Zhu, D. L. Lubkeman, and A. A. Girgis, "Automated fault location and diagnosis on electric power distribution feeders", IEEE Trans. Power Delivery, vol. 12, pp. 801-809, Apr. 1997.
    • (1997) IEEE Trans. Power Delivery , vol.12 , pp. 801-809
    • Zhu, J.1    Lubkeman, D.L.2    Girgis, A.A.3
  • 10
  • 11
    • 0028409151 scopus 로고
    • Using fuzzy sets to model the uncertainty in the fault location process of distribution networks
    • Apr.
    • P. Jarventausta, P. Verho, and P. Partanen, "Using fuzzy sets to model the uncertainty in the fault location process of distribution networks", IEEE Trans. Power Delivery, vol. 9, pp. 954-960, Apr. 1994.
    • (1994) IEEE Trans. Power Delivery , vol.9 , pp. 954-960
    • Jarventausta, P.1    Verho, P.2    Partanen, P.3
  • 14
    • 0038677094 scopus 로고    scopus 로고
    • A novel method for transmission network fault location using genetic algorithms and sparse field recordings
    • Chicago, Illinois
    • M. Kezunovic, S. Luo and D. R. Sevcik, "A novel method for transmission network fault location using genetic algorithms and sparse field recordings" in Proc. 2002 IEEE Power engineering Society Summer Meeting, Chicago, Illinois, pp. 1101-1106.
    • Proc. 2002 IEEE Power Engineering Society Summer Meeting , pp. 1101-1106
    • Kezunovic, M.1    Luo, S.2    Sevcik, D.R.3
  • 15
    • 82955180545 scopus 로고    scopus 로고
    • Localizacao de faltas fase-terra em alimentadores radiais de distribuicao utilizando aquisicao de dados esparsos sincronizados
    • Gramado, Brazil
    • R. A. F. Pereira, L. G. W. da Silva and J. R. S. Mantovani, "Localizacao de faltas fase-terra em alimentadores radiais de distribuicao utilizando aquisicao de dados esparsos sincronizados", in Proc. 2004 XV Congresso Brasileiro de Automatica, Gramado, Brazil.
    • Proc. 2004 XV Congresso Brasileiro de Automatica
    • Pereira, R.A.F.1    Da Silva, L.G.W.2    Mantovani, J.R.S.3
  • 16
    • 82955214100 scopus 로고    scopus 로고
    • Optimized placement of voltage measurement devices for determining location of single line-to-ground faults on overhead electric power distribution feeders
    • Salvador, Brazil
    • R. A. F. Pereira, L. G. W. da Silva, M. Kezunovic and J. R. S. Mantovani, "Optimized placement of voltage measurement devices for determining location of single line-to-ground faults on overhead electric power distribution feeders", submitted to the 2006 XVI Congresso Brasileiro de Automatica, Salvador, Brazil.
    • Submitted to the 2006 XVI Congresso Brasileiro de Automatica
    • Pereira, R.A.F.1    Da Silva, L.G.W.2    Kezunovic, M.3    Mantovani, J.R.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.