메뉴 건너뛰기




Volumn 18, Issue 3, 2011, Pages 206-213

New backstrap vagus electrode for continuous intraoperative neuromonitoring in thyroid surgery

Author keywords

CIONM; continuous intraoperative nerve monitoring; endocrine surgery; intraoperative neuromonitoring (IONM); real time neuromonitoring; recurrent laryngeal nerve; recurrent laryngeal nerve palsy; thyroid surgery; vagus nerve stimulation

Indexed keywords

ARTICLE; CLINICAL ARTICLE; CONTINOUS INTRAOPERATIVE NEUROMONITORING; DEVICE REMOVAL; ELECTRODE; FEMALE; HUMAN; INTRAOPERATIVE PERIOD; LATENT PERIOD; MALE; NERVE CELL MEMBRANE POTENTIAL; NERVE CONDUCTION; NERVE PARALYSIS; NEUROMONITORING; OPERATION DURATION; QUALITY CONTROL; RECURRENT LARYNGEAL NERVE; THYROID SURGERY; VAGUS ELECTRODE; VAGUS NERVE; VAGUS NERVE STIMULATION;

EID: 82955202751     PISSN: 15533506     EISSN: 15533514     Source Type: Journal    
DOI: 10.1177/1553350611409955     Document Type: Article
Times cited : (19)

References (27)
  • 1
    • 37249052275 scopus 로고    scopus 로고
    • Elucidating Mechanisms of Recurrent Laryngeal Nerve Injury During Thyroidectomy and Parathyroidectomy
    • DOI 10.1016/j.jamcollsurg.2007.07.017, PII S1072751507012483
    • Snyder S, Lairmore TC, Hendricks JC, Roberts JW. Elucidating mechanisms of recurrent laryngeal nerve injury during thyroidectomy and parathyroidectomy. J Am Coll Surg. 2008 ; 206: 123-130 (Pubitemid 350267256)
    • (2008) Journal of the American College of Surgeons , vol.206 , Issue.1 , pp. 123-130
    • Snyder, S.K.1    Lairmore, T.C.2    Hendricks, J.C.3    Roberts, J.W.4
  • 2
    • 77949890388 scopus 로고    scopus 로고
    • A new vagal anchor electrode for real-time monitoring of the recurrent laryngeal nerve
    • Schneider R, Przybyl J, Pliquett U. A new vagal anchor electrode for real-time monitoring of the recurrent laryngeal nerve. Am J Surg. 2010 ; 199: 507-514
    • (2010) Am J Surg , vol.199 , pp. 507-514
    • Schneider, R.1    Przybyl, J.2    Pliquett, U.3
  • 3
    • 0032970371 scopus 로고    scopus 로고
    • Effect of training on the incidence of nerve damage in thyroid surgery
    • DOI 10.1046/j.1365-2168.1999.01017.x
    • Lamadé W, Renz K, Willeke F, Klar E, Herfarth C. Effect of training on the incidence of nerve damage in thyroid surgery. Br J Surg. 1999 ; 86: 388-391 (Pubitemid 29145929)
    • (1999) British Journal of Surgery , vol.86 , Issue.3 , pp. 388-391
    • Lamade, W.1    Renz, K.2    Willeke, F.3    Klar, E.4    Herfarth, Ch.5
  • 4
    • 0013918718 scopus 로고
    • Identification of the recurrent laryngeal nerve
    • Shedd DP, Burget GC. Identification of the recurrent laryngeal nerve. Arch Surg. 1966 ; 92: 861-864
    • (1966) Arch Surg , vol.92 , pp. 861-864
    • Shedd, D.P.1    Burget, G.C.2
  • 5
    • 29144471062 scopus 로고    scopus 로고
    • Intraoperative neurophysiology testing of the recurrent laryngeal nerve: Plaudits and pitfalls
    • DOI 10.1016/j.surg.2005.08.027, PII S0039606005005532
    • Snyder SK, Hendricks JC. Intraoperative neurophysiology testing of the recurrent laryngeal nerve: plaudits and pitfalls. Surgery. 2005 ; 138: 1183-1192 (Pubitemid 41797361)
    • (2005) Surgery , vol.138 , Issue.6 , pp. 1183-1192
    • Snyder, S.K.1    Hendricks, J.C.2    Chen, H.3    Dackiw, A.P.B.4    Dralle, H.5
  • 6
    • 0001811123 scopus 로고
    • Electrical stimulation of the human recurrent laryngeal nerve during thyroid operation
    • Flisberg K, Lindholm T. Electrical stimulation of the human recurrent laryngeal nerve during thyroid operation. Acta Otolaryngol. 1970 ; 63: 63-67
    • (1970) Acta Otolaryngol , vol.63 , pp. 63-67
    • Flisberg, K.1    Lindholm, T.2
  • 7
    • 0344199946 scopus 로고    scopus 로고
    • Intraoperative electromyogram monitoring of the recurrent laryngeal nerve: Experience with an intralaryngeal surface electrode
    • Horn D, Rötzscher VM. Intraoperative electromyogram monitoring of the recurrent laryngeal nerve: experience with an intralaryngeal surface electrode. Langenbecks Arch Surg. 1999 ; 84: 392-395
    • (1999) Langenbecks Arch Surg , vol.84 , pp. 392-395
    • Horn, D.1    Rötzscher, V.M.2
  • 8
    • 0032800642 scopus 로고    scopus 로고
    • Identifizierung des Nervus laryngeus recurrens durch intraoperatives Neuromonitoring
    • Kunath M, Hussock J, Marusch F, Horschig P, Gastinger I. Identification of the recurrent laryngeal nerve by intraoperative neuromonitoring [in German]. Zentralbl Chir. 1999 ; 24: 641-645 (Pubitemid 29381161)
    • (1999) Zentralblatt fur Chirurgie , vol.124 , Issue.7 , pp. 641-645
    • Kunath, M.1    Hussock, J.2    Marusch, F.3    Horschig, P.4    Gastinger, I.5
  • 9
    • 0034787871 scopus 로고    scopus 로고
    • Qualitätssicherungsstudie benigne und maligne struma. Prospektive multizentrische erhebungsstudie mit 7 617 patienten
    • DOI 10.1055/s-2001-18249
    • Thomusch O, Sekulla C, Ukkat J, Gastinger L, Lippert H, Dralle H. Quality assurance study of benign and malignant goiter. Prospective multicenter data collection regarding 7,617 patients [in German]. Zentralbl Chir. 2001 ; 126: 664-671 (Pubitemid 32963768)
    • (2001) Zentralblatt fur Chirurgie , vol.126 , Issue.9 , pp. 664-671
    • Thomusch, O.1    Sekulla, C.2    Ukkat, J.3    Gastinger, I.4    Lippert, H.5    Dralle, H.6
  • 11
    • 0033769780 scopus 로고    scopus 로고
    • Multivariate analysis of risk factors for postoperative complications in benign goiter surgery: Prospective multicenter study in Germany
    • Thomusch O, Machens A, Sekulla C, et al. Multivariate analysis of risk factors for postoperative complications in benign goiter surgery: prospective multicenter study in Germany. World J Surg. 2000 ; 24: 1335-1341
    • (2000) World J Surg , vol.24 , pp. 1335-1341
    • Thomusch, O.1    MacHens, A.2    Sekulla, C.3
  • 13
    • 0030116793 scopus 로고    scopus 로고
    • Intraoperatives monitoring des nervus laryngeus recurrens: Eine neue methode
    • Lamadé W, Fogel W, Rieke K, Senninger N, Herfarth C. Intraoperative monitoring of the recurrent laryngeal nerve. A new method [in German]. Chirurg. 1996 ; 67: 451-454 (Pubitemid 126488752)
    • (1996) Chirurg , vol.67 , Issue.4 , pp. 451-454
    • Lamade, W.1    Fogel, W.2    Rieke, K.3    Senninger, N.4    Herfarth, Ch.5
  • 15
    • 0032239869 scopus 로고    scopus 로고
    • Intraoperative monitoring of the recurrent laryngeal nerve in thyroid operations [in German]
    • Brandner R, Lamadé W, Dickhaus H. Intraoperative monitoring of the recurrent laryngeal nerve in thyroid operations [in German]. Biomed Tech (Berl). 1998 ; 43: 142-143
    • (1998) Biomed Tech (Berl) , vol.43 , pp. 142-143
    • Brandner, R.1    Lamadé, W.2    Dickhaus, H.3
  • 16
    • 0034181168 scopus 로고    scopus 로고
    • First continuous nerve monitoring in thyroid gland surgery [in German]
    • Lamadé W, Meyding-Lamadé U, Buchhold C, et al. First continuous nerve monitoring in thyroid gland surgery [in German]. Chirurg. 2000 ; 71: 551-557
    • (2000) Chirurg , vol.71 , pp. 551-557
    • Lamadé, W.1    Meyding-Lamadé, U.2    Buchhold, C.3
  • 18
    • 39149121839 scopus 로고    scopus 로고
    • Real-time monitoring of the recurrent laryngeal nerve: An observational clinical trial
    • Ulmer C, Koch KP, Seimer A, et al. Real-time monitoring of the recurrent laryngeal nerve: an observational clinical trial. Surgery. 2008 ; 143: 359-365
    • (2008) Surgery , vol.143 , pp. 359-365
    • Ulmer, C.1    Koch, K.P.2    Seimer, A.3
  • 19
    • 68549104181 scopus 로고    scopus 로고
    • A new anchor electrode design for continuous neuromonitoring of the recurrent laryngeal nerve by vagal nerve stimulations
    • Schneider R, Przybyl J, Hermann M, Hauss J, Jonas S, Leinung S. A new anchor electrode design for continuous neuromonitoring of the recurrent laryngeal nerve by vagal nerve stimulations. Langenbecks Arch Surg. 2009 ; 394: 903-910
    • (2009) Langenbecks Arch Surg , vol.394 , pp. 903-910
    • Schneider, R.1    Przybyl, J.2    Hermann, M.3    Hauss, J.4    Jonas, S.5    Leinung, S.6
  • 20
    • 77953663800 scopus 로고    scopus 로고
    • Continuous intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroid surgery [in German]
    • Jonas J. Continuous intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroid surgery [in German]. Zentralbl Chir. 2010 ; 135: 273-276
    • (2010) Zentralbl Chir , vol.135 , pp. 273-276
    • Jonas, J.1
  • 21
    • 40549125945 scopus 로고    scopus 로고
    • Incorporation of the electrode-electrolyte interface into finite-element models of metal microelectrodes
    • DOI 10.1088/1741-2560/5/1/006, PII S1741256008545502
    • Cantrell DR, Inayat S, Taflove A, Ruoff RS, Troy JB. Incorporation of the electrode-electrolyte interface into finite-element models of metal microelectrodes. J Neural Eng. 2008 ; 5: 54-67 (Pubitemid 351366603)
    • (2008) Journal of Neural Engineering , vol.5 , Issue.1 , pp. 54-67
    • Cantrell, D.R.1    Inayat, S.2    Taflove, A.3    Ruoff, R.S.4    Troy, J.B.5
  • 22
    • 0014088178 scopus 로고
    • The specific resistance of biological material: A compendium of data for the biomedical engineer and physiologist
    • Geddes LA, Baker LE. The specific resistance of biological material:a compendium of data for the biomedical engineer and physiologist. Med Biol Eng. 1967 ; 5: 271-293
    • (1967) Med Biol Eng , vol.5 , pp. 271-293
    • Geddes, L.A.1    Baker, L.E.2
  • 23
    • 79952492131 scopus 로고    scopus 로고
    • Impact of continuous intraoperative neuromonitoring on autonomic nervous system during thyroid surgery [published online ahead of print November 10, 2010]
    • Ulmer C, Friedrich C, Kohler A, et al. Impact of continuous intraoperative neuromonitoring on autonomic nervous system during thyroid surgery [published online ahead of print November 10, 2010]. Head Neck. :
    • Head Neck
    • Ulmer, C.1    Friedrich, C.2    Kohler, A.3
  • 24
    • 14644425215 scopus 로고    scopus 로고
    • Recurrent laryngeal nerve palsy after thyroidectomy with routine identification of the recurrent laryngeal nerve
    • Chiang FY, Wang LF, Huang YF, Lee KW, Kuo WR. Recurrent laryngeal nerve palsy after thyroidectomy with routine identification of the recurrent laryngeal nerve. Surgery. 2005 ; 137: 342-347
    • (2005) Surgery , vol.137 , pp. 342-347
    • Chiang, F.Y.1    Wang, L.F.2    Huang, Y.F.3    Lee, K.W.4    Kuo, W.R.5
  • 25
    • 77950879771 scopus 로고    scopus 로고
    • Electromyographic response persists after peripheral transection: Endorsement of current concepts in recurrent laryngeal nerve monitoring in a porcine model
    • Birkholz T, Irouschek A, Labahn D, Klein P, Schmidt J. Electromyographic response persists after peripheral transection: endorsement of current concepts in recurrent laryngeal nerve monitoring in a porcine model. Langenbecks Arch Surg. 2010 ; 395: 121-125
    • (2010) Langenbecks Arch Surg , vol.395 , pp. 121-125
    • Birkholz, T.1    Irouschek, A.2    Labahn, D.3    Klein, P.4    Schmidt, J.5
  • 26
    • 77953673231 scopus 로고    scopus 로고
    • Signal evaluation of continuous vagal nerve stimulation for recurrent laryngeal nerve protection in thyroid surgery [in German]
    • Jonas J. Signal evaluation of continuous vagal nerve stimulation for recurrent laryngeal nerve protection in thyroid surgery [in German]. Zentralbl Chir. 2010 ; 135: 262-266
    • (2010) Zentralbl Chir , vol.135 , pp. 262-266
    • Jonas, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.