Volumn 57, Issue 6, 2011, Pages 418-423

A comparison of different methods of temperature measurements in sick newborns

Author keywords

Axillary; Digital; Infrared; Newborn; Rectal; Temperature; Thermometers; Tympanic

Indexed keywords

ACCURACY; ARTICLE; AXILLARY GLASS MERCURY THERMOMETER; DESCRIPTIVE RESEARCH; DIGITAL AXILLARY THERMOMETER; FEMALE; HUMAN; HYPERBILIRUBINEMIA; INFANT; INFRARED FOREHEAD SKIN THERMOMETER; INFRARED TYMPANIC THERMOMETER; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; NEWBORN; NEWBORN DISEASE; NEWBORN INTENSIVE CARE; PERINATAL ASPHYXIA; PREMATURITY; PROSPECTIVE STUDY; RECTAL GLASS MERCURY THERMOMETER; RESPIRATORY TRACT DISEASE; SEPSIS; TEMPERATURE MEASUREMENT; THERMOMETER;

EID: 82955169669     PISSN: 01426338     EISSN: 14653664     Source Type: Journal    
DOI: 10.1093/tropej/fmq120     Document Type: Article
Times cited : (32)

References (27)
  • 1
    • 0003478589 scopus 로고    scopus 로고
    • World Health Organization. World Health Organization. WHO/RHT/MSM/97.2
    • World Health Organization. Thermal protection of the newborn: a practical guide. World Health Organization. WHO/RHT/MSM/97.2, 1997.
    • (1997) Thermal protection of the newborn: a practical guide
  • 2
    • 33745841866 scopus 로고    scopus 로고
    • Measuring temperature of NICU patients-A comparison of three devices
    • Rosenthal HM, Leslie A. Measuring temperature of NICU patients-A comparison of three devices. J Neonatal Nurs 2006;12:125-9.
    • (2006) J Neonatal Nurs , vol.12 , pp. 125-129
    • Rosenthal, H.M.1    Leslie, A.2
  • 3
    • 82955224337 scopus 로고    scopus 로고
    • National Association of Neonatal Nurses, (NANN). Glenview, IL: NANN
    • National Association of Neonatal Nurses (NANN). Neonatal thermoregulation guidelines for practice. Glenview, IL: NANN, 1997.
    • (1997) Neonatal thermoregulation guidelines for practice
  • 5
    • 0025753707 scopus 로고
    • Infrared, thermistor, and glass-mercury thermometry for measurement of body temperature in children with cancer
    • Shenep JL, Adair JR, Hughes WT, et al. Infrared, thermistor, and glass-mercury thermometry for measurement of body temperature in children with cancer. Clin Pediatr 1991;30(Suppl. 4):36-41.
    • (1991) Clin Pediatr , vol.30 , Issue.SUPPL. 4 , pp. 36-41
    • Shenep, J.L.1    Adair, J.R.2    Hughes, W.T.3
  • 6
    • 0034150529 scopus 로고    scopus 로고
    • A comparison of four methods of normal newborn temperature measurement
    • Sganga A, Wallace R, Kiehl E, et al. A comparison of four methods of normal newborn temperature measurement. MCN Am J Matern Child Nurs 2000;25:76-9.
    • (2000) MCN Am J Matern Child Nurs , vol.25 , pp. 76-79
    • Sganga, A.1    Wallace, R.2    Kiehl, E.3
  • 7
    • 36549040975 scopus 로고    scopus 로고
    • Recommended standards for the newborn ICU
    • White RD. Recommended standards for the newborn ICU. J Perinatol 2007;27:S4-19.
    • (2007) J Perinatol , vol.27
    • White, R.D.1
  • 8
    • 44649096089 scopus 로고    scopus 로고
    • Temperature control and disorders
    • Rennie JM (ed.) 4th edn. Philadelphia: Elsevier Churchill Livingstone
    • Rutter N. Temperature control and disorders. In: Rennie JM (ed.). Roberton's Textbook of Neonatology, 4th edn. Philadelphia: Elsevier Churchill Livingstone, 2005; pp. 267-79.
    • (2005) Roberton's Textbook of Neonatology , pp. 267-279
    • Rutter, N.1
  • 9
    • 0026919798 scopus 로고
    • Thermoregulation and axillary temperature measurements in neonates: a review of the literature
    • Keeling EB. Thermoregulation and axillary temperature measurements in neonates: a review of the literature. Matern Child Nurs J 1992;20:124-40.
    • (1992) Matern Child Nurs J , vol.20 , pp. 124-140
    • Keeling, E.B.1
  • 10
    • 33846333497 scopus 로고    scopus 로고
    • Measurement accuracy of fever by tympanic and axillary thermometry
    • Devrim I, Kara A, Ceyhan M, et al. Measurement accuracy of fever by tympanic and axillary thermometry. Pediatr Emerg Care 2007;23:16-9.
    • (2007) Pediatr Emerg Care , vol.23 , pp. 16-19
    • Devrim, I.1    Kara, A.2    Ceyhan, M.3
  • 11
    • 0032200771 scopus 로고    scopus 로고
    • Are electronic thermometry techniques suitable alternatives to traditional mercury in glass thermometry techniques in the paediatric setting?
    • Smith J. Are electronic thermometry techniques suitable alternatives to traditional mercury in glass thermometry techniques in the paediatric setting? J Adv Nurs 1998; 28:1030-9.
    • (1998) J Adv Nurs , vol.28 , pp. 1030-1039
    • Smith, J.1
  • 12
    • 0032130313 scopus 로고    scopus 로고
    • A comparison of temperature-taking methods in neonates
    • Leick-Rude MK, Bloom LF. A comparison of temperature-taking methods in neonates. Neonatal Netw 1998;17:21-37.
    • (1998) Neonatal Netw , vol.17 , pp. 21-37
    • Leick-Rude, M.K.1    Bloom, L.F.2
  • 14
    • 0036680024 scopus 로고    scopus 로고
    • Infrared tympanic thermometer can accurately measure the body temperature in children in an emergency room setting
    • Kocoglu H, Goksu S, Isik M, et al. Infrared tympanic thermometer can accurately measure the body temperature in children in an emergency room setting. Int J Pediatr Otorhinolaryngol 2002;65:39-43.
    • (2002) Int J Pediatr Otorhinolaryngol , vol.65 , pp. 39-43
    • Kocoglu, H.1    Goksu, S.2    Isik, M.3
  • 15
    • 0028276301 scopus 로고
    • Accuracy of infrared ear thermometry and traditional temperature methods in young children
    • Erickson RS, Woo TM. Accuracy of infrared ear thermometry and traditional temperature methods in young children. Heart Lung 1994;23:181-95.
    • (1994) Heart Lung , vol.23 , pp. 181-195
    • Erickson, R.S.1    Woo, T.M.2
  • 16
    • 0031242183 scopus 로고    scopus 로고
    • Core body temperature measurement: a comparison of axilla, tympanic membrane and pulmonary artery blood temperature
    • Fulbrook P. Core body temperature measurement: a comparison of axilla, tympanic membrane and pulmonary artery blood temperature. Intensive Crit Care Nurs 1997;13:266-72.
    • (1997) Intensive Crit Care Nurs , vol.13 , pp. 266-272
    • Fulbrook, P.1
  • 17
    • 0028540782 scopus 로고
    • Infrared tympanic thermometry for neonatal temperature assessment
    • Weiss ME, Poeltler D, Gocka I. Infrared tympanic thermometry for neonatal temperature assessment. J Obstet Gynecol Neonatal Nurs 1994;23:798-804.
    • (1994) J Obstet Gynecol Neonatal Nurs , vol.23 , pp. 798-804
    • Weiss, M.E.1    Poeltler, D.2    Gocka, I.3
  • 18
    • 0025755602 scopus 로고
    • Tympanic infrared thermometry for fullterm and preterm neonates
    • Weiss ME. Tympanic infrared thermometry for fullterm and preterm neonates. Clin Pediatr 1991;30(Suppl. 4):42-5.
    • (1991) Clin Pediatr , vol.30 , Issue.SUPPL. 4 , pp. 42-45
    • Weiss, M.E.1
  • 19
    • 0027251664 scopus 로고
    • Comparison of temperature measurements by an aural infrared thermometer with measurements by traditional rectal and axillary techniques
    • Yetman RJ, Coody DK, West MS, et al. Comparison of temperature measurements by an aural infrared thermometer with measurements by traditional rectal and axillary techniques. J Pediatr 1993;122:769-73.
    • (1993) J Pediatr , vol.122 , pp. 769-773
    • Yetman, R.J.1    Coody, D.K.2    West, M.S.3
  • 20
    • 0043005423 scopus 로고
    • Comparisons of rectal, femoral, axillary, and skin-tomattress temperatures in stable neonates
    • Kunnel MT, O'Brien C, Munro BH, Medoff-Cooper B. Comparisons of rectal, femoral, axillary, and skin-tomattress temperatures in stable neonates. Nurs Res 1988;37:162-4.
    • (1988) Nurs Res , vol.37 , pp. 162-164
    • Kunnel, M.T.1    O'Brien, C.2    Munro, B.H.3    Medoff-Cooper, B.4
  • 21
    • 0005124371 scopus 로고    scopus 로고
    • Comparisons of tympanic membrane, abdominal skin, axillary, and rectal temperature measurements in term and preterm neonates
    • Jirapaet V, Jirapaet K. Comparisons of tympanic membrane, abdominal skin, axillary, and rectal temperature measurements in term and preterm neonates. Nurs Health Sci 2000;2:1-8.
    • (2000) Nurs Health Sci , vol.2 , pp. 1-8
    • Jirapaet, V.1    Jirapaet, K.2
  • 22
    • 0027655208 scopus 로고
    • Core temperature measurements in adults: a literature review
    • Fulbrook P. Core temperature measurements in adults: a literature review. J Adv Nurs 1993;18:1451-60.
    • (1993) J Adv Nurs , vol.18 , pp. 1451-1460
    • Fulbrook, P.1
  • 23
    • 46049104907 scopus 로고    scopus 로고
    • Axillary and rectal temperature measurements poorly agree in newborn infants
    • Hissink Muller PC, van Berkel LH, de Beaufort AJ. Axillary and rectal temperature measurements poorly agree in newborn infants. Neonatology 2008;94:31-4.
    • (2008) Neonatology , vol.94 , pp. 31-34
    • Hissink Muller, P.C.1    van Berkel, L.H.2    de Beaufort, A.J.3
  • 24
    • 0034728879 scopus 로고    scopus 로고
    • Temperature measured at the axilla compared with rectum in children and young people: systematic review
    • Craig JV, Lancaster GA, Williamson PR, et al. Temperature measured at the axilla compared with rectum in children and young people: systematic review. Br Med J 2000;320:1174-8.
    • (2000) Br Med J , vol.320 , pp. 1174-1178
    • Craig, J.V.1    Lancaster, G.A.2    Williamson, P.R.3
  • 25
    • 82955202188 scopus 로고    scopus 로고
    • Infrared skin thermometer good alternative for newborns
    • Kemp C. Infrared skin thermometer good alternative for newborns. AAP News 2008;29:2.
    • (2008) AAP News , vol.29 , pp. 2
    • Kemp, C.1
  • 26
    • 77956630953 scopus 로고    scopus 로고
    • Comparison of non-contact infrared forehead thermometer to standard temperature measurement in neonatal intensive care unit patients
    • Can E, Bulbul A, Uslu S, et al. Comparison of non-contact infrared forehead thermometer to standard temperature measurement in neonatal intensive care unit patients. Turk Arch Ped 2010;45:257-63.
    • (2010) Turk Arch Ped , vol.45 , pp. 257-263
    • Can, E.1    Bulbul, A.2    Uslu, S.3
  • 27
    • 0031041834 scopus 로고    scopus 로고
    • Comparison of tympanic, esophageal and blood temperatures during mild hypothermic cardiopulmonary bypass: a study using an infrared emission detection tympanic thermometer
    • Harasawa K, Kemmotsu O, Mayumi T, et al. Comparison of tympanic, esophageal and blood temperatures during mild hypothermic cardiopulmonary bypass: a study using an infrared emission detection tympanic thermometer. J Clin Monit 1997;13:19-24.
    • (1997) J Clin Monit , vol.13 , pp. 19-24
    • Harasawa, K.1    Kemmotsu, O.2    Mayumi, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.