메뉴 건너뛰기




Volumn , Issue , 2011, Pages

Harmonic impacts of widespread use of CFL lamps on distribution systems

Author keywords

Compact Fluorescent Lamps; Distribution system analysis; Harmonic analysis; Harmonic filters

Indexed keywords

CAPACITOR BANK; COMPACT FLUORESCENT LAMP; COMPACT FLUORESCENT LIGHTS; DISTRIBUTION SUBSTATIONS; DISTRIBUTION SYSTEM ANALYSIS; DISTRIBUTION SYSTEM MODELS; DISTRIBUTION SYSTEMS; HARMONIC FILTER; HARMONIC INJECTION; HARMONIC LEVELS; HARMONIC SPECTRUM; HIGH HARMONICS; LABORATORY TEST; POTENTIAL SOLUTIONS; REACTIVE COMPENSATION; RESIDENTIAL LOADS; VOLTAGE DISTORTIONS; WORST CASE SCENARIO;

EID: 82855178044     PISSN: 19449925     EISSN: 19449933     Source Type: Conference Proceeding    
DOI: 10.1109/PES.2011.6039496     Document Type: Conference Paper
Times cited : (22)

References (10)
  • 1
    • 82855164503 scopus 로고    scopus 로고
    • a Joint Program of the U.S. Environmental Protection Agency and the U.S. Department of Energy
    • Energy Star, a Joint Program of the U.S. Environmental Protection Agency and the U.S. Department of Energy, URL http://www.energystar.gov/index.cfm?c= cfls.pr-cfls.
  • 2
    • 67650701031 scopus 로고    scopus 로고
    • Power Quality Effects of CFLs - A Field Study
    • Gothelf, N., " Power Quality Effects of CFLs - A Field Study", Proc. Right Light 4, 2, pp. 77-81.
    • Proc. Right Light , vol.4 , Issue.2 , pp. 77-81
    • Gothelf, N.1
  • 3
    • 82855184032 scopus 로고    scopus 로고
    • Polish Efficient Lighting Project (PELP) - the DSM Pilot Project
    • Polish Efficient Lighting Project (PELP) - the DSM Pilot Project, URl www.resourcesaver.com/file/toolmanager/O105UF677.pdf
  • 5
    • 84865432353 scopus 로고    scopus 로고
    • Side Effects of Energy Saving Lamps
    • Athens, Greece
    • Mielczarski, W. et al., "Side Effects of Energy Saving Lamps", ICHQP 1998, Athens, Greece, 1998.
    • (1998) ICHQP 1998
    • Mielczarski, W.1
  • 6
    • 82855166212 scopus 로고    scopus 로고
    • prepared for
    • "Domestic Lamp Replacement Project Technology Impact Assessment", prepared for Sustainability Victoria by Econnct, URL http://www.sustainability.vic.gov.au/www/html/2662-domestic-lamp-replacement- project-technology-impact-assessment.asp.
    • Domestic Lamp Replacement Project Technology Impact Assessment
  • 8
    • 82855166211 scopus 로고    scopus 로고
    • OpenDSS Program, Available on SOURCEFORGE.NET
    • OpenDSS Program, Available on SOURCEFORGE.NET, URL:http://sourceforge. net/projects/electricdss.
  • 9
    • 82855184031 scopus 로고    scopus 로고
    • PQView Program, URL: http://www.pqview.com/


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.