Volumn , Issue , 2011, Pages

Implementation of an experimental wide-area monitoring platform for development of synchronized phasor measurement applications

Author keywords

PMU based Applications; Wide Area Monitoring and Control Systems Performance; Wide Area Monitoring System

Indexed keywords

BASIC APPLICATION; DATA APPLICATION; INFORMATION AND COMMUNICATION; INTERNATIONAL RESEARCHES; MONITORING AND CONTROL; OFF-LINE ANALYSIS; ONLINE MONITORING; RESEARCH AND DEVELOPMENT; SMART GRID; SYNCHRONIZED PHASOR MEASUREMENTS; TRANSMISSION SYSTEM OPERATORS; WIDE AREA MONITORING; WIDE AREA MONITORING AND CONTROL SYSTEMS; WIDE AREA MONITORING SYSTEM;

EID: 82855177925     PISSN: 19449925     EISSN: 19449933     Source Type: Conference Proceeding    
DOI: 10.1109/PES.2011.6039672     Document Type: Conference Paper
Times cited : (19)

References (28)
  • 1
    • 78649933344 scopus 로고    scopus 로고
    • The Next Generation of Power Distribution Systems
    • Dec
    • G. Heydt, "The Next Generation of Power Distribution Systems," IEEE Transactions on Smart Grid, vol. 1, no. 3, pp. 225-235, Dec 2010.
    • (2010) IEEE Transactions on Smart Grid , vol.1 , Issue.3 , pp. 225-235
    • Heydt, G.1
  • 2
    • 77952885648 scopus 로고    scopus 로고
    • Smart Transmission Grid Applications and Their Supporting Infrastructure
    • June
    • A. Bose, "Smart Transmission Grid Applications and Their Supporting Infrastructure," IEEE Transactions on Smart Grid, vol. 1, no. 1, pp. 11-19, June 2010.
    • (2010) IEEE Transactions on Smart Grid , vol.1 , Issue.1 , pp. 11-19
    • Bose, A.1
  • 3
    • 79952910208 scopus 로고    scopus 로고
    • (RAPIR Chair), North American Elecricity Reliability Corporation, Princeton, Princeton, NJ, Tech. Rep., available on-line
    • M. Patel (RAPIR Chair), "Real-Time Application of Synchrophasors Improving Reliability," North American Elecricity Reliability Corporation, Princeton, Princeton, NJ, Tech. Rep., 2010, available on-line: http://www.naspi.org/news/rapirfinaldraft20101017.pdf.
    • (2010) Real-Time Application of Synchrophasors Improving Reliability
    • Patel, M.1
  • 4
    • 21244436499 scopus 로고    scopus 로고
    • Design aspects for wide-area monitoring and control systems
    • DOI 10.1109/JPROC.2005.846336, Energy Infrastructure Defense Systems
    • M. Zima, M. Larsson, P. Korba, C. Rehtanz, and G. Andersson, "Design Aspects for Wide-Area Monitoring and Control Systems," Proceedings of the IEEE, vol. 93, no. 5, pp. 980-996, May 2005. (Pubitemid 40891830)
    • (2005) Proceedings of the IEEE , vol.93 , Issue.5 , pp. 980-996
    • Zima, M.1    Larsson, M.2    Korba, P.3    Rehtanz, C.4    Andersson, G.5
  • 11
    • 82855182589 scopus 로고    scopus 로고
    • available on-line
    • "F-NET Server Web Display," available on-line: http://fnetpublic.utk.edu/.
    • F-NET Server Web Display
  • 16
    • 77952885267 scopus 로고    scopus 로고
    • A Flexible Phasor Data Concentrator Design Leveraging Existing Software Technologies
    • June
    • A. Armenia and J. H. Chow, "A Flexible Phasor Data Concentrator Design Leveraging Existing Software Technologies," IEEE Transactions on Smart Grid, vol. 1, no. 1, pp. 73-81, June 2010.
    • (2010) IEEE Transactions on Smart Grid , vol.1 , Issue.1 , pp. 73-81
    • Armenia, A.1    Chow, J.H.2
  • 17
    • 84888588104 scopus 로고    scopus 로고
    • available on-line
    • "The TVA Code Library," available on-line: http:// tvacodelibrary.codeplex.com/.
    • The TVA Code Library
  • 18
    • 79957532902 scopus 로고    scopus 로고
    • Application of Ambient Analysis Techniques for the Estimation of Electromechanical Oscillations from Measured PMU Data in Four Different Power Systems
    • Special Issue on PMU Data and their Applications, doi: 10.1002/etep.507
    • L. Vanfretti, L. Dosiek, J. W. Pierre, D. Trudnowski, J. H. Chow, R. García-Valle, and U. Aliyu, "Application of Ambient Analysis Techniques for the Estimation of Electromechanical Oscillations from Measured PMU Data in Four Different Power Systems," European Transactions on Electrical Power, 2010, Special Issue on PMU Data and their Applications, doi: 10.1002/etep.507.
    • (2010) European Transactions on Electrical Power
    • Vanfretti, L.1    Dosiek, L.2    Pierre, J.W.3    Trudnowski, D.4    Chow, J.H.5    García-Valle, R.6    Aliyu, U.7
  • 22
    • 13344259932 scopus 로고    scopus 로고
    • Performance of "WAMS East" in providing dynamic information for the North East blackout of August 14, 2003
    • J. Hauer, N. Bhatt, K. Shah, and S. Kolluri, "Performance of "WAMS East" in providing dynamic information for the North East blackout of August 14, 2003," in IEEE Power Engineering Society General Meeting, 2004, pp. 1685-1690.
    • IEEE Power Engineering Society General Meeting, 2004 , pp. 1685-1690
    • Hauer, J.1    Bhatt, N.2    Shah, K.3    Kolluri, S.4
  • 23
    • 82855182557 scopus 로고    scopus 로고
    • Use of COMTRADE for Exchange of PMU Data
    • available on-line
    • E. Allen, "Use of COMTRADE for Exchange of PMU Data," in NASPI Workgroup Meeting, Vancouver, British Columbia, June 2010, available on-line: http://www.naspi.org/meetings/workgroup/2010-june/presentations/session-01/ allen-nerc-use-of-comtrade-20100608.pdf.
    • NASPI Workgroup Meeting, Vancouver, British Columbia, June 2010
    • Allen, E.1
  • 24
    • 78149460871 scopus 로고    scopus 로고
    • Intelligent Design: Substation Data Integration for Enhanced Asset Management Opportunities
    • Nov.-Dec.
    • M. Kezunovic, "Intelligent Design: Substation Data Integration for Enhanced Asset Management Opportunities," IEEE Power and Energy Magazine, vol. 6, no. 6, pp. 37-44, Nov.-Dec. 2010.
    • (2010) IEEE Power and Energy Magazine , vol.6 , Issue.6 , pp. 37-44
    • Kezunovic, M.1
  • 27
    • 43849093477 scopus 로고    scopus 로고
    • Performance of three mode-meter block-processing algorithms for automated dynamic stability assessment
    • DOI 10.1109/TPWRS.2008.919415
    • D. Trudnowski, J. Pierre, N. Zhou, J. Hauer, and M. Parashar, "Performance of Three Mode-Meter Block-Processing Algorithms for Automated Dynamic Stability Assessment," IEEE Transactions on Power Systems, vol. 23, no. 2, pp. 680-690, May 2008. (Pubitemid 351695848)
    • (2008) IEEE Transactions on Power Systems , vol.23 , Issue.2 , pp. 680-690
    • Trudnowski, D.J.1    Pierre, J.W.2    Zhou, N.3    Hauer, J.F.4    Parashar, M.5
  • 28
    • 78649597016 scopus 로고    scopus 로고
    • Signal Processing Methods for Estimating Small-Signal Dynamic Properties from Measured Responses
    • Inter-area Oscillations in Power Systems: A Nonlinear and Nonstationary Perspective, ser. A. R. Messina, Ed. Springer, ch.
    • D. Trudnowski and J.W. Pierre, in Inter-area Oscillations in Power Systems: A Nonlinear and Nonstationary Perspective, ser. Power Electronics and Power Systems, A. R. Messina, Ed. Springer, 2009, ch. Signal Processing Methods for Estimating Small-Signal Dynamic Properties from Measured Responses, pp. 1-36.
    • (2009) Power Electronics and Power Systems , pp. 1-36
    • Trudnowski, D.1    Pierre, J.W.2