메뉴 건너뛰기




Volumn , Issue , 2011, Pages

Model reduction, validation, and calibration of wind power plants for dynamic studies

Author keywords

model calibration; model validation; parameter identification; power system dynamic performance; wind power plants; wind turbine generators

Indexed keywords

ACCURACY IMPROVEMENT; ACCURATE RESPONSE; DYNAMIC STUDIES; MODEL CALIBRATION; MODEL REDUCTION; MODEL VALIDATION; OFFLINE; ONE-MACHINE; POWER SYSTEM DYNAMIC PERFORMANCE; POWER SYSTEM STABILITY; REDUCED MODEL; TEST SYSTEMS; TWO-LINE; WIND GENERATION;

EID: 82855177862     PISSN: 19449925     EISSN: 19449933     Source Type: Conference Proceeding    
DOI: 10.1109/PES.2011.6039782     Document Type: Conference Paper
Times cited : (17)

References (22)
  • 1
    • 68349150311 scopus 로고    scopus 로고
    • Impact of Increased Penetration of DFIG-Based Wind Turbine Generators on Transient and Small Signal Stability of Power Systems
    • D. Gautam, D. Vittal and T. Harbour, "Impact of Increased Penetration of DFIG-Based Wind Turbine Generators on Transient and Small Signal Stability of Power Systems," Power Systems, IEEE Transactions on, vol. 24, pp. 1426-1434, 2009.
    • (2009) Power Systems, IEEE Transactions on , vol.24 , pp. 1426-1434
    • Gautam, D.1    Vittal, D.2    Harbour, T.3
  • 10
    • 0037291008 scopus 로고    scopus 로고
    • General model for representing variable speed wind turbines in power system dynamics simulations
    • J. G. Slootweg, S.W.H. de Haan, H. Polinder, and W.L. King, "General model for representing variable speed wind turbines in power system dynamics simulations," Power Systems, IEEE Transactions on, vol. 18, pp. 144-151, 2003.
    • (2003) Power Systems, IEEE Transactions on , vol.18 , pp. 144-151
    • Slootweg, J.G.1    De Haan, S.W.H.2    Polinder, H.3    King, W.L.4
  • 15
    • 39749106781 scopus 로고    scopus 로고
    • Reducing Identified Parameters of Measurement-Based Composite Load Model
    • J. Ma, D. Han, R. M. He, Z. Y. Dong, and D. J. Hill, "Reducing Identified Parameters of Measurement-Based Composite Load Model,"Power Systems, IEEE Transactions on, vol. 23, pp. 76-83, 2008.
    • (2008) Power Systems, IEEE Transactions on , vol.23 , pp. 76-83
    • Ma, J.1    Han, D.2    He, R.M.3    Dong, Z.Y.4    Hill, D.J.5
  • 16
    • 58949102910 scopus 로고    scopus 로고
    • Equivalent models of wind farms by using aggregated wind turbines and equivalent winds
    • Mar
    • L. M. Fernandez, C. A. Garcia, J. R. Saenz and F. Jurado, "Equivalent models of wind farms by using aggregated wind turbines and equivalent winds," Energy Conversion and Management, vol. 50, pp. 691-704, Mar 2009.
    • (2009) Energy Conversion and Management , vol.50 , pp. 691-704
    • Fernandez, L.M.1    Garcia, C.A.2    Saenz, J.R.3    Jurado, F.4
  • 19
    • 82855161907 scopus 로고    scopus 로고
    • DIgSILENT, 14.0 ed., DIgital SImuLation and Electrical NeTwork calculation program
    • DIgSILENT, "DIgSILENT PowerFactory," 14.0 ed., 2010, DIgital SImuLation and Electrical NeTwork calculation program.
    • (2010) DIgSILENT PowerFactory


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.