메뉴 건너뛰기




Volumn 301, Issue 6, 2011, Pages 2254-2263

Mis-sizing of stent promotes intimal hyperplasia: Impact of endothelial shear and intramural stress

Author keywords

Circumferential wall stress; Fluid wall shear stress; In stent restenosis; Stent sizing

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTERY INTIMA PROLIFERATION; ARTICLE; BLOOD VESSEL WALL; COMPUTER MODEL; CONTROLLED STUDY; CORONARY ARTERY; NONHUMAN; PRIORITY JOURNAL; SHEAR STRESS; STENT; SWINE;

EID: 82855169306     PISSN: 03636135     EISSN: 15221539     Source Type: Journal    
DOI: 10.1152/ajpheart.00240.2011     Document Type: Article
Times cited : (48)

References (47)
  • 1
    • 45249091884 scopus 로고    scopus 로고
    • Appropriate use of drug-eluting stents: Balancing the reduction in restenosis with the concern of late thrombosis
    • Bavry A, Bhatt D. Appropriate use of drug-eluting stents: balancing the reduction in restenosis with the concern of late thrombosis. Lancet 371: 2134-2143, 2008.
    • (2008) Lancet , vol.371 , pp. 2134-2143
    • Bavry, A.1    Bhatt, D.2
  • 2
    • 33846803611 scopus 로고    scopus 로고
    • Late thrombosis of drug-eluting stents: A meta-analysis of randomized clinical trials
    • Bavry AA, Kumbhani DJ, Helton TJ, Borek PP, Mood GR, Bhatt DL. Late thrombosis of drug-eluting stents: a meta-analysis of randomized clinical trials. Am J Med 119: 1056-1061, 2006.
    • (2006) Am J Med , vol.119 , pp. 1056-1061
    • Bavry, A.A.1    Kumbhani, D.J.2    Helton, T.J.3    Borek, P.P.4    Mood, G.R.5    Bhatt, D.L.6
  • 6
    • 34147176083 scopus 로고    scopus 로고
    • Stent thrombosis late after implantation of first-generation drug-eluting stents
    • Camenzind E, Steg PG, Wijns W. Stent thrombosis late after implantation of first-generation drug-eluting stents. Circulation 115: 1440-1455, 2007.
    • (2007) Circulation , vol.115 , pp. 1440-1455
    • Camenzind, E.1    Steg, P.G.2    Wijns, W.3
  • 8
    • 66349132501 scopus 로고    scopus 로고
    • Effects of intravascular stent sizing on endothelial and vessel wall stress: Potential mechanisms of in-stent restenosis
    • Chen HY, Hermiller J, Sinha AK, Sturek M, Zhu L, Kassab GS. Effects of intravascular stent sizing on endothelial and vessel wall stress: potential mechanisms of in-stent restenosis. J Appl Physiol 106: 686-691, 2009.
    • (2009) J Appl Physiol , vol.106 , pp. 686-691
    • Chen, H.Y.1    Hermiller, J.2    Sinha, A.K.3    Sturek, M.4    Zhu, L.5    Kassab, G.S.6
  • 9
    • 68749120576 scopus 로고    scopus 로고
    • Vessel-clamp interaction: Transient closure dynamics
    • Chen HY, Navia JA, Kassab GS. Vessel-clamp interaction: transient closure dynamics. Ann Biomed Eng 37: 1772-1780, 2009.
    • (2009) Ann Biomed Eng , vol.37 , pp. 1772-1780
    • Chen, H.Y.1    Navia, J.A.2    Kassab, G.S.3
  • 11
    • 84890006337 scopus 로고    scopus 로고
    • Computational modeling of coronary stents
    • edited by Mofrad MR, Guilak FS. New York: Springer
    • Chen HY, Kassab GS. Computational modeling of coronary stents. In: Computational Biomechanics, edited by Mofrad MR, Guilak FS. New York: Springer, 2010.
    • (2010) Computational Biomechanics
    • Chen, H.Y.1    Kassab, G.S.2
  • 13
    • 33847767113 scopus 로고    scopus 로고
    • Mechanotransduction and endothelial cell homeostasis: The wisdom of the cell
    • Chien S. Mechanotransduction and endothelial cell homeostasis: the wisdom of the cell. Am J Physiol Heart Circ Physiol 292: H1209-H1224, 2007.
    • (2007) Am J Physiol Heart Circ Physiol , vol.292
    • Chien, S.1
  • 15
    • 0013873058 scopus 로고
    • Effects of hematocrit and plasma proteins on human blood rheology at low shear rates
    • Chien S, Usami S, Taylor M, Lundberg JL, Gergersem MI. Effects of hematocrit and plasma proteins on human blood rheology at low shear rates. J Appl Physiol 21: 81-87, 1966.
    • (1966) J Appl Physiol , vol.21 , pp. 81-87
    • Chien, S.1    Usami, S.2    Taylor, M.3    Lundberg, J.L.4    Gergersem, M.I.5
  • 17
    • 0037129873 scopus 로고    scopus 로고
    • Systemic inflammation induced by lipopolysaccharide increases neointimal formation after balloon and stent injury in rabbits
    • Danenberg HD, Welt FG, Walker 3rd M, Seifert P, Toegel GS, Edelman ER. Systemic inflammation induced by lipopolysaccharide increases neointimal formation after balloon and stent injury in rabbits. Circulation 105: 2917-2922, 2002.
    • (2002) Circulation , vol.105 , pp. 2917-2922
    • Danenberg, H.D.1    Welt, F.G.2    Walker, M.3    Seifert, P.4    Toegel, G.S.5    Edelman, E.R.6
  • 18
    • 29844442623 scopus 로고    scopus 로고
    • Shear stress biology of the endothelium
    • Davies PF, Spaan JA, Krams R. Shear stress biology of the endothelium. Ann Biomed Eng 33: 1714-1718, 2005.
    • (2005) Ann Biomed Eng , vol.33 , pp. 1714-1718
    • Davies, P.F.1    Spaan, J.A.2    Krams, R.3
  • 23
    • 19944431861 scopus 로고    scopus 로고
    • Association of a negative residual stenosis following rescue/adjunctive percutaneous coronary intervention with impaired myocardial perfusion and adverse outcomes among ST-segment elevation myocardial infarction patients
    • TIMI Study Group
    • Gibson CM, Kirtane AJ, Boundy K, Ly H, Karmpaliotis D, Murphy SA, Giugliano RP, Cannon CP, Antman EM, Braunwald E; TIMI Study Group. Association of a negative residual stenosis following rescue/adjunctive percutaneous coronary intervention with impaired myocardial perfusion and adverse outcomes among ST-segment elevation myocardial infarction patients. J Am Coll Cardiol 45: 357-362, 2005.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 357-362
    • Gibson, C.M.1    Kirtane, A.J.2    Boundy, K.3    Ly, H.4    Karmpaliotis, D.5    Murphy, S.A.6    Giugliano, R.P.7    Cannon, C.P.8    Antman, E.M.9    Braunwald, E.10
  • 24
    • 0036786031 scopus 로고    scopus 로고
    • Coronary artery stretch versus deep injury in the development of in-stent neointima
    • Gunn J, Arnold N, Chan KH, Shepherd L, Cumberland DC, Crossman DC. Coronary artery stretch versus deep injury in the development of in-stent neointima. Heart 88: 401-405, 2002.
    • (2002) Heart , vol.88 , pp. 401-405
    • Gunn, J.1    Arnold, N.2    Chan, K.H.3    Shepherd, L.4    Cumberland, D.C.5    Crossman, D.C.6
  • 25
    • 23644444112 scopus 로고    scopus 로고
    • Blood flow in stented arteries: A parametric comparison of strut design patterns in three dimensions
    • He Y, Duraiswamy N, Frank AO, Moore JE. Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions. J Biomech Eng 127: 637-647, 2005.
    • (2005) J Biomech Eng , vol.127 , pp. 637-647
    • He, Y.1    Duraiswamy, N.2    Frank, A.O.3    Moore, J.E.4
  • 26
    • 36148991420 scopus 로고    scopus 로고
    • Flow patterns in three-dimensional porcine epicardial coronary arterial tree
    • Huo Y, Wischgoll T, Kassab GS. Flow patterns in three-dimensional porcine epicardial coronary arterial tree. Am J Physiol Heart Circ Physiol 293: H2959-H2970, 2007.
    • (2007) Am J Physiol Heart Circ Physiol , vol.293
    • Huo, Y.1    Wischgoll, T.2    Kassab, G.S.3
  • 27
    • 80053452786 scopus 로고    scopus 로고
    • Inflammatory markers and restenosis in peripheral percutaneous angioplasty with intravascular stenting: Current concepts
    • Joviliano EE, Piccinato CE, Moriya T, Evora PR. Inflammatory markers and restenosis in peripheral percutaneous angioplasty with intravascular stenting: current concepts. Ann Vasc Surg 25: 846-855, 2011.
    • (2011) Ann Vasc Surg , vol.25 , pp. 846-855
    • Joviliano, E.E.1    Piccinato, C.E.2    Moriya, T.3    Evora, P.R.4
  • 29
    • 0642311549 scopus 로고    scopus 로고
    • Blood flow in arteries. Annual review of fluid mechanics
    • Ku DN. Blood flow in arteries. Annual review of fluid mechanics. Ann Rev 29: 399-434, 1997.
    • (1997) Ann Rev , vol.29 , pp. 399-434
    • Ku, D.N.1
  • 30
    • 0041381421 scopus 로고    scopus 로고
    • Three-dimensional computational fluid dynamics modeling of alterations in coronary wall shear stress produced by stent implantation
    • LaDisa JF Jr, Guler I, Olson LE, Hettrick DA, Kersten JR, Warltier DC, Pagel PS. Three-dimensional computational fluid dynamics modeling of alterations in coronary wall shear stress produced by stent implantation. Ann Biomed Eng 31: 972-980, 2003.
    • (2003) Ann Biomed Eng , vol.31 , pp. 972-980
    • Ladisa Jr., J.F.1    Guler, I.2    Olson, L.E.3    Hettrick, D.A.4    Kersten, J.R.5    Warltier, D.C.6    Pagel, P.S.7
  • 31
    • 20444475661 scopus 로고    scopus 로고
    • Cardiovascular stent design and vessel stresses: A finite element analysis
    • Lally C, Dolan F, Prendergast PJ. Cardiovascular stent design and vessel stresses: a finite element analysis. J Biomech 38: 1574-1581, 2005.
    • (2005) J Biomech , vol.38 , pp. 1574-1581
    • Lally, C.1    Dolan, F.2    Prendergast, P.J.3
  • 33
    • 0042358966 scopus 로고    scopus 로고
    • Pattern formation of vascular smooth muscle cells subject to nonuniform fluid shear stress: Role of PDGF-β receptor and Src
    • Liu SQ, Tieche C, Tang D, Alkema P. Pattern formation of vascular smooth muscle cells subject to nonuniform fluid shear stress: role of PDGF-β receptor and Src. Am J Physiol Heart Circ Physiol 285: H1081-H1090, 2003.
    • (2003) Am J Physiol Heart Circ Physiol , vol.285
    • Liu, S.Q.1    Tieche, C.2    Tang, D.3    Alkema, P.4
  • 34
    • 54549106998 scopus 로고    scopus 로고
    • Drug-eluting stents in the real world: How intravascular ultrasound can improve clinical outcome
    • Moses JW, Dangas G, Mehran R, Mintz GS. Drug-eluting stents in the real world: how intravascular ultrasound can improve clinical outcome. Am J Cardiol 102: 24-28, 2008.
    • (2008) Am J Cardiol , vol.102 , pp. 24-28
    • Moses, J.W.1    Dangas, G.2    Mehran, R.3    Mintz, G.S.4
  • 35
    • 0003633755 scopus 로고    scopus 로고
    • National Research Council, Washington, DC: National Academy
    • National Research Council. Guide for the Care and Use of Laboratory Animals. Washington, DC: National Academy, 1996.
    • (1996) Guide For the Care and Use of Laboratory Animals
  • 37
    • 32544450138 scopus 로고    scopus 로고
    • Experimental and modeling study of Newtonian and non-Newtonian fluid flow in pore network micromodels
    • Perrin CL, Tardy PM, Sorbie KS, Crawshaw JC. Experimental and modeling study of Newtonian and non-Newtonian fluid flow in pore network micromodels. J Colloid Interface Sci 295: 542-550, 2006.
    • (2006) J Colloid Interface Sci , vol.295 , pp. 542-550
    • Perrin, C.L.1    Tardy, P.M.2    Sorbie, K.S.3    Crawshaw, J.C.4
  • 38
    • 33847420978 scopus 로고    scopus 로고
    • Numerical modeling of simulated blood flow in idealized composite arterial coronary grafts: Steady state simulations
    • Politis AK, Christolistos MN, Panagopoulos FG, Vlachos NS, Markatos N. Numerical modeling of simulated blood flow in idealized composite arterial coronary grafts: steady state simulations. J Biomech 40: 1125-1136, 2007.
    • (2007) J Biomech , vol.40 , pp. 1125-1136
    • Politis, A.K.1    Christolistos, M.N.2    Panagopoulos, F.G.3    Vlachos, N.S.4    Markatos, N.5
  • 39
    • 33744994739 scopus 로고    scopus 로고
    • Pushing drug eluting stents into uncharted territory: Simpler than you think-more complex than you imagine
    • Rogers C, Edelman ER. Pushing drug eluting stents into uncharted territory: simpler than you think-more complex than you imagine. Circulation 113: 2262-2265, 2006.
    • (2006) Circulation , vol.113 , pp. 2262-2265
    • Rogers, C.1    Edelman, E.R.2
  • 41
    • 0037299724 scopus 로고    scopus 로고
    • Influence of residual stenosis after percutaneous coronary intervention with stent implantation on development of restenosis and stent thrombosis
    • Sick P, Hüttl T, Niebauer J, Thiele H, Lauer B, Hambrecht R, Hentschel B, Schuler G. Influence of residual stenosis after percutaneous coronary intervention with stent implantation on development of restenosis and stent thrombosis. Am J Cardiol 91: 148-153, 2003.
    • (2003) Am J Cardiol , vol.91 , pp. 148-153
    • Sick, P.1    Hüttl, T.2    Niebauer, J.3    Thiele, H.4    Lauer, B.5    Hambrecht, R.6    Hentschel, B.7    Schuler, G.8
  • 42
    • 0023684259 scopus 로고
    • Inhibition of atherosclerosis associated with reduction of arterial intramural stress in rabbits
    • Thubrikar MJ, Baker JW, Nolan SP. Inhibition of atherosclerosis associated with reduction of arterial intramural stress in rabbits. Arteriosclerosis 8: 410-420, 1988.
    • (1988) Arteriosclerosis , vol.8 , pp. 410-420
    • Thubrikar, M.J.1    Baker, J.W.2    Nolan, S.P.3
  • 44
    • 79957622044 scopus 로고    scopus 로고
    • Increased artery wall stress post-stenting leads to greater intimal thickening
    • Timmins LH, Miller MW, Clubb FJ Jr, Moore JE Jr. Increased artery wall stress post-stenting leads to greater intimal thickening. Lab Invest 91: 955-967, 2011.
    • (2011) Lab Invest , vol.91 , pp. 955-967
    • Timmins, L.H.1    Miller, M.W.2    Clubb Jr., F.J.3    Moore Jr., J.E.4
  • 45
    • 33748417592 scopus 로고    scopus 로고
    • Three-dimensional mechanical properties of porcine coronary arteries: A validated two-layer model
    • Wang C, Garcia M, Lu X, Lanir Y, Kassab GS. Three-dimensional mechanical properties of porcine coronary arteries: a validated two-layer model. Am J Physiol Heart Circ Physiol 291: H1200-H1209, 2006.
    • (2006) Am J Physiol Heart Circ Physiol , vol.291
    • Wang, C.1    Garcia, M.2    Lu, X.3    Lanir, Y.4    Kassab, G.S.5
  • 46
    • 0030001720 scopus 로고    scopus 로고
    • Effect of carotid artery geometry on the magnitude and distribution of wall shear stress gradients
    • Wells DR, Archie JP Jr, Kleinstreuer C,. Effect of carotid artery geometry on the magnitude and distribution of wall shear stress gradients. J Vasc Surg 23: 667-678, 1996.
    • (1996) J Vasc Surg , vol.23 , pp. 667-678
    • Wells, D.R.1    Archie Jr., J.P.2    Kleinstreuer, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.