메뉴 건너뛰기




Volumn 38, Issue 12, 2011, Pages 6384-6394

Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: A feasibility study

Author keywords

4D CT; 4D MRI; cine MRI; respiratory motion; tumor motion

Indexed keywords

COMPUTERIZED TOMOGRAPHY; PATIENT MONITORING; PHANTOMS; RADIOTHERAPY; RESPIRATORY MECHANICS; TUMORS;

EID: 82755198800     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3658737     Document Type: Article
Times cited : (174)

References (27)
  • 1
    • 0842306300 scopus 로고    scopus 로고
    • 4-Dimensional Computed Tomography Imaging and Treatment Planning
    • DOI 10.1053/j.semradonc.2003.10.006
    • P. Keall, 4-dimensional computed tomography imaging and treatment planning., Semin. Radiat. Oncol. 14, 81-90 (2004). 10.1053/j.semradonc.2003.10. 006 (Pubitemid 38168957)
    • (2004) Seminars in Radiation Oncology , vol.14 , Issue.1 , pp. 81-90
    • Keall, P.1
  • 4
    • 14644439819 scopus 로고    scopus 로고
    • Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT
    • DOI 10.1118/1.1855013
    • T. Pan, Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT., Med. Phys. 32, 627-634 (2005). 10.1118/1.1855013 (Pubitemid 40322344)
    • (2005) Medical Physics , vol.32 , Issue.2 , pp. 627-634
    • Pan, T.1
  • 5
    • 17844371743 scopus 로고    scopus 로고
    • Four-dimensional computed tomography: Image formation and clinical protocol
    • DOI 10.1118/1.1869852
    • E. Rietzel, T. Pan, and T. Y. Chen, Four-dimensional computed tomography: Image formation and clinical protocol., Med. Phys. 32, 874-889 (2005). 10.1118/1.1869852 (Pubitemid 40586772)
    • (2005) Medical Physics , vol.32 , Issue.4 , pp. 874-889
    • Rietzel, E.1    Pan, T.2    Chen, G.T.Y.3
  • 9
    • 65649094133 scopus 로고    scopus 로고
    • 4D-MRI analysis of lung tumor motion in patients with hemidiaphragmatic paralysis
    • 10.1016/j.radonc.2009.03.021
    • J. Dinkel 4D-MRI analysis of lung tumor motion in patients with hemidiaphragmatic paralysis., Radither. Onocl. 91, 449-454 (2009). 10.1016/j.radonc.2009.03.021
    • (2009) Radither. Onocl. , vol.91 , pp. 449-454
    • Dinkel, J.1
  • 10
    • 33747623309 scopus 로고    scopus 로고
    • MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning
    • DOI 10.1088/0031-9155/51/17/003, PII S0031915506097880, 003
    • J. M. Blackall MRI-based measurements of respiratory motion varibility and assessment of imaging strategies for radiotherapy planning., Phys. Med. Biol. 51, 4147-4169 (2006). 10.1088/0031-9155/51/17/003 (Pubitemid 44261837)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.17 , pp. 4147-4169
    • Blackall, J.M.1    Ahmad, S.2    Miquel, M.E.3    McClelland, J.R.4    Landau, D.B.5    Hawkes, D.J.6
  • 11
    • 35848936522 scopus 로고    scopus 로고
    • Four-dimensional magnetic resonance imaging for the determination of tumour movement and its evaluation using a dynamic porcine lung phantom
    • DOI 10.1088/0031-9155/52/18/N02, PII S0031915507434340
    • G. Remmert Four-dimensional magnetic resonance imaging for the determination of tumour movement and its evaluation using a dynamic porcine lung phantom., Phys. Med. Biol. 52, N401-N415 (2007). 10.1088/0031-9155/52/18/N02 (Pubitemid 350056695)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.18
    • Remmert, G.1    Biederer, J.2    Lohberger, F.3    Fabel, M.4    Hartmann, G.H.5
  • 15
    • 33947718548 scopus 로고    scopus 로고
    • Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI
    • DOI 10.1088/0031-9155/52/2/004, PII S0031915507308452, 004
    • J. Cai Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI., Phys. Med. Biol. 52, 365-373 (2007). 10.1088/0031-9155/52/2/004 (Pubitemid 46646457)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.2 , pp. 365-373
    • Cai, J.1    Read, P.W.2    Altes, T.A.3    Molloy, J.A.4    Brookeman, J.R.5    Sheng, K.6
  • 16
    • 0034265741 scopus 로고    scopus 로고
    • High-speed magnetic resonance imaging for four-dimensional treatment planning of conformal radiotherapy of moving body tumors
    • 10.1016/S0360-3016(00)00624-6
    • S. Shimizu High-speed magnetic resonance imaging for four-dimensional treatment planning of conformal radiotherapy of moving body tumors., Int. J. Radiat. Oncol., Biol., Phys. 48, 471-474 (2000). 10.1016/S0360-3016(00)00624-6
    • (2000) Int. J. Radiat. Oncol., Biol., Phys. , vol.48 , pp. 471-474
    • Shimizu, S.1
  • 17
    • 39049188390 scopus 로고    scopus 로고
    • Imaging tumour motion for radiotherapy planning using MRI
    • 10.1102/1470-7330.2006.9027
    • H. U. Kauczor and C. Plathow, Imaging tumour motion for radiotherapy planning using MRI., Cancer Imaging 31, S140-S144 (2006). 10.1102/1470-7330. 2006.9027
    • (2006) Cancer Imaging , vol.31
    • Kauczor, H.U.1    Plathow, C.2
  • 18
    • 78149440200 scopus 로고    scopus 로고
    • Utility of the FIESTA Pulse Sequence in Body Oncologic Imaging: Review
    • 10.2214/AJR.07.7062
    • P. Bhosale, J. Ma, and H. Choi, Utility of the FIESTA Pulse Sequence in Body Oncologic Imaging: Review., Am. J. Roentgenol. 192, S83-S93 (2009). 10.2214/AJR.07.7062
    • (2009) Am. J. Roentgenol. , vol.192
    • Bhosale, P.1    Ma, J.2    Choi, H.3
  • 19
    • 82755189105 scopus 로고    scopus 로고
    • Evaluating dynamic magnetic resonance imaging using a new design of phantom: Validation with fast megavoltage fluoroscopic imaging
    • Philadelphia PA.
    • Z. Chang Evaluating dynamic magnetic resonance imaging using a new design of phantom: validation with fast megavoltage fluoroscopic imaging., Proceedings of AAPM 52nd Annual Meeting, Philadelphia PA, (2010).
    • (2010) Proceedings of AAPM 52nd Annual Meeting
    • Chang, Z.1
  • 20
    • 77956299682 scopus 로고    scopus 로고
    • 4D XCAT phantom for multimodality imaging research
    • 10.1118/1.3480985.
    • W. P. Segars 4D XCAT phantom for multimodality imaging research., Med. Phys. 37, 4902-4915 (2010) 10.1118/1.3480985.
    • (2010) Med. Phys. , vol.37 , pp. 4902-4915
    • Segars, W.P.1
  • 21
    • 70450162884 scopus 로고    scopus 로고
    • MCAT to XCAT: The Evolution of 4-D Computerised Phantoms for Imaging Research
    • 10.1109/JPROC.2009.2022417.
    • W. P. Segars MCAT to XCAT: The Evolution of 4-D Computerised Phantoms for Imaging Research., Proc. IEEE 97, 1954-1968 (2009) 10.1109/JPROC.2009.2022417.
    • (2009) Proc. IEEE , vol.97 , pp. 1954-1968
    • Segars, W.P.1
  • 22
    • 48349124497 scopus 로고    scopus 로고
    • Realistic CT simulation using the 4D XCAT phantom
    • 10.1118/1.2955743.
    • W. P. Segars Realistic CT simulation using the 4D XCAT phantom., Med Phys, 35, 3800-3808 (2008) 10.1118/1.2955743.
    • (2008) Med Phys , vol.35 , pp. 3800-3808
    • Segars, W.P.1
  • 23
    • 78650635391 scopus 로고    scopus 로고
    • Evaluation of respiratory liver and kidney movements for MRI navigator gating
    • 10.1002/jmri.22418.
    • R. Song Evaluation of respiratory liver and kidney movements for MRI navigator gating., J. Magn. Reson Imaging 33, 143-148 (2011) 10.1002/jmri.22418.
    • (2011) J. Magn. Reson Imaging , vol.33 , pp. 143-148
    • Song, R.1
  • 24
    • 2042542085 scopus 로고    scopus 로고
    • A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging
    • DOI 10.1016/j.mri.2004.01.008, PII S0730725X04000268
    • D. Wang A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging., Magn. Reson. Imaging 22, 529-542 (2004) 10.1016/j.mri.2004.01.008. (Pubitemid 38534669)
    • (2004) Magnetic Resonance Imaging , vol.22 , Issue.4 , pp. 529-542
    • Wang, D.1    Doddrell, D.M.2    Cowin, G.3
  • 25
    • 84998548722 scopus 로고    scopus 로고
    • Step and Shoot MRI: A Simple Acquisition Method to Reduce Gradient Nonlinearity-Induced Geometric Distortions for Radiation Treatment Planning
    • 10.1118/1.3560418.
    • E. S. Paulson Step and Shoot MRI: a Simple Acquisition Method to Reduce Gradient Nonlinearity-Induced Geometric Distortions for Radiation Treatment Planning., Med. Phys. 38, 3770 (2011) 10.1118/1.3560418.
    • (2011) Med. Phys. , vol.38 , pp. 3770
    • Paulson, E.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.