메뉴 건너뛰기




Volumn 3, Issue 4, 2011, Pages 559-563

Evaluation of defibrillation efficacy at implantation is unnecessary

Author keywords

Defibrillation efficacy; Defibrillation threshold testing; Implantable defibrillator; Sudden cardiac death

Indexed keywords

DEFIBRILLATION; DEFIBRILLATOR; ELECTRODE; HEART DEATH; HEART MUSCLE CELL; HEART PACING; HEART VENTRICLE ARRHYTHMIA; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HUMAN; PRIORITY JOURNAL; PROBABILITY; RESUSCITATION; REVIEW; RISK ASSESSMENT; STROKE; SUDDEN DEATH; T WAVE;

EID: 82755189979     PISSN: 18779182     EISSN: 18779190     Source Type: Journal    
DOI: 10.1016/j.ccep.2011.08.013     Document Type: Review
Times cited : (1)

References (26)
  • 1
    • 9844224486 scopus 로고    scopus 로고
    • The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators. A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias
    • The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators. A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. N Engl J Med 1997, 337:1576-1583.
    • (1997) N Engl J Med , vol.337 , pp. 1576-1583
  • 2
    • 0037149716 scopus 로고    scopus 로고
    • Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
    • Moss A.J., Zareba W., Hall W.J., et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 2002, 346:877-883.
    • (2002) N Engl J Med , vol.346 , pp. 877-883
    • Moss, A.J.1    Zareba, W.2    Hall, W.J.3
  • 3
    • 19944429413 scopus 로고    scopus 로고
    • Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
    • Bardy G.H., Lee K.L., Mark D.B., et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med 2005, 352:225-237.
    • (2005) N Engl J Med , vol.352 , pp. 225-237
    • Bardy, G.H.1    Lee, K.L.2    Mark, D.B.3
  • 4
    • 0028122160 scopus 로고
    • Implantation by electrophysiologists of 100 consecutive cardioverter defibrillators with nonthoracotomy lead systems
    • Strickberger S.A., Hummel J.D., Daoud E., et al. Implantation by electrophysiologists of 100 consecutive cardioverter defibrillators with nonthoracotomy lead systems. Circulation 1994, 90:868-872.
    • (1994) Circulation , vol.90 , pp. 868-872
    • Strickberger, S.A.1    Hummel, J.D.2    Daoud, E.3
  • 5
    • 0027936720 scopus 로고
    • Effect of shock polarity on ventricular defibrillation threshold using a transvenous lead system
    • Strickberger S.A., Hummel J.D., Horwood L.E., et al. Effect of shock polarity on ventricular defibrillation threshold using a transvenous lead system. J Am Coll Cardiol 1994, 24:1069-1072.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 1069-1072
    • Strickberger, S.A.1    Hummel, J.D.2    Horwood, L.E.3
  • 6
    • 0030237562 scopus 로고    scopus 로고
    • Effects of an active pectoral-pulse generator shell on defibrillation efficacy with a transvenous lead system
    • Gold M.R., Foster A.H., Shorofsky S.R. Effects of an active pectoral-pulse generator shell on defibrillation efficacy with a transvenous lead system. Am J Cardiol 1996, 78:540-543.
    • (1996) Am J Cardiol , vol.78 , pp. 540-543
    • Gold, M.R.1    Foster, A.H.2    Shorofsky, S.R.3
  • 7
    • 0030671317 scopus 로고    scopus 로고
    • Effect of biphasic waveforms on transvenous defibrillation thresholds in patients with coronary artery disease
    • Olsovsky M.R., Hodgson D.M., Shorofsky S.R., et al. Effect of biphasic waveforms on transvenous defibrillation thresholds in patients with coronary artery disease. Am J Cardiol 1997, 80:1098-1100.
    • (1997) Am J Cardiol , vol.80 , pp. 1098-1100
    • Olsovsky, M.R.1    Hodgson, D.M.2    Shorofsky, S.R.3
  • 8
    • 0023127807 scopus 로고
    • Defibrillation threshold: a simple and quantitative estimate of the ability to defibrillate
    • Rattes M.F., Jones D.L., Sharma A.D., et al. Defibrillation threshold: a simple and quantitative estimate of the ability to defibrillate. Pacing Clin Electrophysiol 1987, 10:70-77.
    • (1987) Pacing Clin Electrophysiol , vol.10 , pp. 70-77
    • Rattes, M.F.1    Jones, D.L.2    Sharma, A.D.3
  • 9
    • 0023786718 scopus 로고
    • Relation of the intraoperative defibrillation threshold to successful postoperative defibrillation with an automatic implantable cardioverter defibrillator
    • Marchlinski F.E., Flores B., Miller J.M., et al. Relation of the intraoperative defibrillation threshold to successful postoperative defibrillation with an automatic implantable cardioverter defibrillator. Am J Cardiol 1988, 62:393-398.
    • (1988) Am J Cardiol , vol.62 , pp. 393-398
    • Marchlinski, F.E.1    Flores, B.2    Miller, J.M.3
  • 10
    • 17744402108 scopus 로고    scopus 로고
    • Probability of successful defibrillation at multiples of the defibrillation energy requirement in patients with an implantable defibrillator
    • Strickberger S.A., Daoud E.G., Davidson T., et al. Probability of successful defibrillation at multiples of the defibrillation energy requirement in patients with an implantable defibrillator. Circulation 1997, 96:1217-1223.
    • (1997) Circulation , vol.96 , pp. 1217-1223
    • Strickberger, S.A.1    Daoud, E.G.2    Davidson, T.3
  • 11
    • 13544250737 scopus 로고    scopus 로고
    • One conversion of ventricular fibrillation is adequate for implantable cardioverter-defibrillator implant: an analysis from the Low Energy Safety Study (LESS)
    • Higgins S., Mann D., Calkins H., et al. One conversion of ventricular fibrillation is adequate for implantable cardioverter-defibrillator implant: an analysis from the Low Energy Safety Study (LESS). Heart Rhythm 2005, 2:117-122.
    • (2005) Heart Rhythm , vol.2 , pp. 117-122
    • Higgins, S.1    Mann, D.2    Calkins, H.3
  • 12
    • 0027212169 scopus 로고
    • Relation between upper limit of vulnerability and defibrillation threshold in humans
    • Chen P.S., Feld G.K., Kriett J.M., et al. Relation between upper limit of vulnerability and defibrillation threshold in humans. Circulation 1993, 88:186-192.
    • (1993) Circulation , vol.88 , pp. 186-192
    • Chen, P.S.1    Feld, G.K.2    Kriett, J.M.3
  • 13
    • 0028043915 scopus 로고
    • Upper limit of vulnerability reliably predicts the defibrillation threshold in humans
    • Hwang C., Swerdlow C.D., Kass R.M., et al. Upper limit of vulnerability reliably predicts the defibrillation threshold in humans. Circulation 1994, 90:2308-2314.
    • (1994) Circulation , vol.90 , pp. 2308-2314
    • Hwang, C.1    Swerdlow, C.D.2    Kass, R.M.3
  • 14
    • 34248162434 scopus 로고    scopus 로고
    • Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: risk reduction evaluation with implantable cardioverter-defibrillator implantations)
    • Day J.D., Doshi R.N., Belott P., et al. Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: risk reduction evaluation with implantable cardioverter-defibrillator implantations). Circulation 2007, 115:2382-2389.
    • (2007) Circulation , vol.115 , pp. 2382-2389
    • Day, J.D.1    Doshi, R.N.2    Belott, P.3
  • 15
    • 0026657534 scopus 로고
    • Clinical characteristics and outcome of patients with high defibrillation thresholds. A multicenter study
    • Epstein A.E., Ellenbogen K.A., Kirk K.A., et al. Clinical characteristics and outcome of patients with high defibrillation thresholds. A multicenter study. Circulation 1992, 86:1206-1216.
    • (1992) Circulation , vol.86 , pp. 1206-1216
    • Epstein, A.E.1    Ellenbogen, K.A.2    Kirk, K.A.3
  • 16
    • 20244387585 scopus 로고    scopus 로고
    • Defibrillation threshold testing: is it really necessary at the time of implantable cardioverter-defibrillator insertion?
    • Russo A.M., Sauer W., Gerstenfeld E.P., et al. Defibrillation threshold testing: is it really necessary at the time of implantable cardioverter-defibrillator insertion?. Heart Rhythm 2005, 2:456-461.
    • (2005) Heart Rhythm , vol.2 , pp. 456-461
    • Russo, A.M.1    Sauer, W.2    Gerstenfeld, E.P.3
  • 17
    • 78650126085 scopus 로고    scopus 로고
    • Defibrillation testing at the time of ICD Insertion: an analysis from the Ontario ICD registry
    • Ontario ICD Database Investigators
    • Healey J.S., Birnie D.H., Lee D.S., Ontario ICD Database Investigators, et al. Defibrillation testing at the time of ICD Insertion: an analysis from the Ontario ICD registry. J Cardiovasc Electrophysiol 2010, 21:1344-1348.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 1344-1348
    • Healey, J.S.1    Birnie, D.H.2    Lee, D.S.3
  • 18
    • 33644778037 scopus 로고    scopus 로고
    • Intraoperative testing of the implantable cardioverter-defibrillator: how much is enough?
    • Pires L.A., Johnson K.M. Intraoperative testing of the implantable cardioverter-defibrillator: how much is enough?. J Cardiovasc Electrophysiol 2006, 17:140-145.
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 140-145
    • Pires, L.A.1    Johnson, K.M.2
  • 19
    • 79955436789 scopus 로고    scopus 로고
    • Defibrillation threshold testing fails to show clinical benefit during long-term follow-up of patients undergoing cardiac resynchronization therapy defibrillator implantation
    • Michowitz Y., Lellouche N., Contractor T., et al. Defibrillation threshold testing fails to show clinical benefit during long-term follow-up of patients undergoing cardiac resynchronization therapy defibrillator implantation. Europace 2011, 13:683-688.
    • (2011) Europace , vol.13 , pp. 683-688
    • Michowitz, Y.1    Lellouche, N.2    Contractor, T.3
  • 20
    • 71849086249 scopus 로고    scopus 로고
    • Intraoperative defibrillation threshold testing during implantable cardioverter-defibrillator insertion: do we really need it?
    • Calvi V., Dugo D., Capodanno D., et al. Intraoperative defibrillation threshold testing during implantable cardioverter-defibrillator insertion: do we really need it?. Am Heart J 2010, 159:98-102.
    • (2010) Am Heart J , vol.159 , pp. 98-102
    • Calvi, V.1    Dugo, D.2    Capodanno, D.3
  • 21
    • 65649083360 scopus 로고    scopus 로고
    • Primary prevention implantation of cardioverter defibrillator without defibrillation threshold testing: 2-year follow-up
    • Bianchi S., Ricci R.P., Biscione F., et al. Primary prevention implantation of cardioverter defibrillator without defibrillation threshold testing: 2-year follow-up. Pacing Clin Electrophysiol 2009, 32:573-578.
    • (2009) Pacing Clin Electrophysiol , vol.32 , pp. 573-578
    • Bianchi, S.1    Ricci, R.P.2    Biscione, F.3
  • 22
    • 41449085152 scopus 로고    scopus 로고
    • Is defibrillation testing still necessary? a decision analysis and Markov model
    • Gula L.J., Massel D., Krahn A.D., et al. Is defibrillation testing still necessary? a decision analysis and Markov model. J Cardiovasc Electrophysiol 2008, 19:400-405.
    • (2008) J Cardiovasc Electrophysiol , vol.19 , pp. 400-405
    • Gula, L.J.1    Massel, D.2    Krahn, A.D.3
  • 23
    • 48449094224 scopus 로고    scopus 로고
    • No benefit from defibrillation threshold testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial)
    • Blatt J.A., Poole J.E., Johnson G.W., et al. No benefit from defibrillation threshold testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial). J Am Coll Cardiol 2008, 52:551-556.
    • (2008) J Am Coll Cardiol , vol.52 , pp. 551-556
    • Blatt, J.A.1    Poole, J.E.2    Johnson, G.W.3
  • 24
    • 15644375417 scopus 로고    scopus 로고
    • Effect of ventricular shock strength on cardiac hemodynamics
    • Tokano T., Bach D., Chang J., et al. Effect of ventricular shock strength on cardiac hemodynamics. J Cardiovasc Electrophysiol 1998, 9:791-797.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 791-797
    • Tokano, T.1    Bach, D.2    Chang, J.3
  • 25
    • 39649088013 scopus 로고    scopus 로고
    • Complications associated with defibrillation threshold testing: the Canadian experience
    • Birnie D., Tung S., Simpson C., et al. Complications associated with defibrillation threshold testing: the Canadian experience. Heart Rhythm 2008, 5:387-390.
    • (2008) Heart Rhythm , vol.5 , pp. 387-390
    • Birnie, D.1    Tung, S.2    Simpson, C.3
  • 26
    • 78650134861 scopus 로고    scopus 로고
    • A novel design for a randomized trial to test if ICD implantation without any defibrillation testing is as effective as standard treatment
    • Healey J.S., Hohnloser S.H., Glikson M., et al. A novel design for a randomized trial to test if ICD implantation without any defibrillation testing is as effective as standard treatment. Heart Rhythm 2009, 6:S374.
    • (2009) Heart Rhythm , vol.6
    • Healey, J.S.1    Hohnloser, S.H.2    Glikson, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.