Volumn 56, Issue 24, 2011, Pages 7813-7827

Experimental characterization of lateral profiles of scanned proton and carbon ion pencil beams for improved beam models in ion therapy treatment planning

Author keywords

[No Author keywords available]

Indexed keywords

BEAM LINES; BEAM MODEL; BEAM PROFILES; BEAM THERAPY; CALCULATION MODELS; CALCULATION TIME; CENTRAL AXIS; DOSE CALCULATION; EXPERIMENTAL CHARACTERIZATION; EXPERIMENTAL DATA; GAUSSIAN FUNCTIONS; HEIDELBERG; ION THERAPY; LOW DOSE; MONTE CARLO SIMULATION; MULTIPLE COULOMB SCATTERINGS; NUCLEAR INTERACTION; PENCIL BEAM; SECONDARY PARTICLES; TREATMENT PLANNING; TREATMENT PLANNING SYSTEMS;

EID: 82555196663     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/56/24/009     Document Type: Article
Times cited : (76)

References (15)
  • 1
    • 77950433745 scopus 로고    scopus 로고
    • AAPM Task Group Report no 105: Monte Carlo-based treatment planning
    • Chetty I J 2007 AAPM Task Group Report no 105: Monte Carlo-based treatment planning Med. Phys. 34 4833
    • (2007) Med. Phys. , vol.34 , pp. 4818
    • Chetty, I.J.1
  • 2
    • 0028799438 scopus 로고
    • Deconvolution of detector size effect for small field measurement
    • Higgins P, Sibata C, Siskind L and Sohn J 1995 Deconvolution of detector size effect for small field measurement Med. Phys. 22 16636
    • (1995) Med. Phys. , vol.22 , pp. 1663-1666
    • Higgins, P.1    Sibata, C.2    Siskind, L.3    Sohn, J.4
  • 5
    • 67649616700 scopus 로고    scopus 로고
    • Field-size effect of physical doses in carbon-ion scanning using range shifter plates
    • Inaniwa T, Furukawa T, Nagano A, Sato S, Saotome N, Noda K and Kanai T 2009 Field-size effect of physical doses in carbon-ion scanning using range shifter plates Med. Phys. 36 288997
    • (2009) Med. Phys. , vol.36 , pp. 2889-2897
    • Inaniwa, T.1    Furukawa, T.2    Nagano, A.3    Sato, S.4    Saotome, N.5    Noda, K.6    Kanai, T.7
  • 6
    • 0345035258 scopus 로고    scopus 로고
    • A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions
    • Karger C P, Jkel O, Hartmann G H and Heeg P 1999 A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions Med. Phys. 26 212535
    • (1999) Med. Phys. , vol.26 , pp. 2125-2135
    • Karger, C.P.1    Jkel, O.2    Hartmann, G.H.3    Heeg, P.4
  • 7
    • 0033773556 scopus 로고    scopus 로고
    • Treatment planning for heavy-ion radiotherapy physical beam model and dose optimization
    • Krmer M, Jkel O, Haberer T, Kraft G, Schardt D and Weber U 2000 Treatment planning for heavy-ion radiotherapy physical beam model and dose optimization Phys. Med. Biol. 45 3299
    • (2000) Phys. Med. Biol. , vol.45 , pp. 3299
    • Krmer, M.1    Jkel, O.2    Haberer, T.3    Kraft, G.4    Schardt, D.5    Weber, U.6
  • 9
    • 84879910259 scopus 로고    scopus 로고
    • The Heidelberg Ion Therapy (HIT) accelerator coming into operation
    • Ondreka D and Weinrich U 2008 The Heidelberg Ion Therapy (HIT) accelerator coming into operation Proc. EPAC08 (Genoa, Italy,) pp 97981
    • (2008) Proc. EPAC08 , pp. 979-981
    • Ondreka, D.1    Weinrich, U.2
  • 11
    • 14544292041 scopus 로고    scopus 로고
    • Experimental characterization and physical modelling of the dose distribution of scanned proton pencil beams
    • Pedroni E, Scheib S, Bhringer T, Coray A, Grossmann M, Lin S and Lomax A 2005 Experimental characterization and physical modelling of the dose distribution of scanned proton pencil beams Phys. Med. Biol. 50 541
    • (2005) Phys. Med. Biol. , vol.50 , pp. 541
    • Pedroni, E.1    Scheib, S.2    Bhringer, T.3    Coray, A.4    Grossmann, M.5    Lin, S.6    Lomax, A.7
  • 15
    • 0037152067 scopus 로고    scopus 로고
    • Two-dimensional pencil beam scaling: An improved proton dose algorithm for heterogeneous media
    • DOI 10.1088/0031-9155/47/18/304, PII S0031915502352576
    • Szymanowski H and Oelfke U 2002 Two-dimensional pencil beam scaling: an improved proton dose algorithm for heterogeneous media Phys. Med. Biol. 47 331330 (Pubitemid 35174225)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.18 , pp. 3313-3330
    • Szymanowski, H.1    Oelfke, U.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.