메뉴 건너뛰기




Volumn 75, Issue 12, 2011, Pages 2789-2797

Mechanisms of non-fatal stent-related myocardial infarction late following coronary stenting with drug-eluting stents and bare metal stents: Insights from optical coherence tomography

Author keywords

Bare metal stent; Drug eluting stent; Myocardial infarction; Optical coherence tomography

Indexed keywords

ADULT; ANGIOCARDIOGRAPHY; ARTERY THROMBOSIS; ARTICLE; BARE METAL STENT; BLOOD VESSEL RUPTURE; CLINICAL ARTICLE; CONTROLLED STUDY; CORONARY ARTERY ATHEROSCLEROSIS; CORONARY ARTERY CALCIFICATION; CORONARY STENT; DEVICE SAFETY; DRUG ELUTING STENT; FEMALE; HEART INFARCTION; HUMAN; HYPERPLASIA; MALE; NEOINTIMA; NEOVASCULARIZATION (PATHOLOGY); OBSERVATIONAL STUDY; OPTICAL COHERENCE TOMOGRAPHY; PROSPECTIVE STUDY; RESTENOSIS; WOUND HEALING IMPAIRMENT;

EID: 82455210522     PISSN: 13469843     EISSN: 13474820     Source Type: Journal    
DOI: 10.1253/circj.CJ-11-0581     Document Type: Article
Times cited : (14)

References (29)
  • 1
    • 77649250571 scopus 로고    scopus 로고
    • Mechanisms of nonfatal acute myocardial infarction late after stent implantation: The relative impact of disease progression, stent restenosis, and stent thrombosis
    • Alexopoulos D, Xanthopoulou I, Davlouros P, Damelou A, Mazarakis A, Chiladakis J, et al. Mechanisms of nonfatal acute myocardial infarction late after stent implantation: The relative impact of disease progression, stent restenosis, and stent thrombosis. Am Heart J 2010; 159: 439-445.
    • (2010) Am Heart J , vol.159 , pp. 439-445
    • Alexopoulos, D.1    Xanthopoulou, I.2    Davlouros, P.3    Damelou, A.4    Mazarakis, A.5    Chiladakis, J.6
  • 2
    • 68249122647 scopus 로고    scopus 로고
    • Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis
    • Cook S, Ladich E, Nakazawa G, Eshtehardi P, Neidhart M, Vogel R, et al. Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis. Circulation 2009; 120: 391-399.
    • (2009) Circulation , vol.120 , pp. 391-399
    • Cook, S.1    Ladich, E.2    Nakazawa, G.3    Eshtehardi, P.4    Neidhart, M.5    Vogel, R.6
  • 3
    • 73349119081 scopus 로고    scopus 로고
    • Delayed neointimalization on drug-eluting stents: Speculation from optical coherence tomography
    • Shite J. Delayed neointimalization on drug-eluting stents: Speculation from optical coherence tomography. Circ J 2009; 73: 2210-2211.
    • (2009) Circ J , vol.73 , pp. 2210-2211
    • Shite, J.1
  • 4
    • 34248219973 scopus 로고    scopus 로고
    • Pathological correlates of late drug-eluting stent thrombosis: Strut coverage as a marker of endothelialization
    • Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, et al. Pathological correlates of late drug-eluting stent thrombosis: Strut coverage as a marker of endothelialization. Circulation 2007; 115: 2435-2441.
    • (2007) Circulation , vol.115 , pp. 2435-2441
    • Finn, A.V.1    Joner, M.2    Nakazawa, G.3    Kolodgie, F.4    Newell, J.5    John, M.C.6
  • 6
    • 65549117911 scopus 로고    scopus 로고
    • Atherosclerotic and thrombogenic neointima formed over sirolimus drug-eluting stent: An angioscopic study
    • Higo T, Ueda Y, Oyabu J, Okada K, Nishio M, Hirata A, et al. Atherosclerotic and thrombogenic neointima formed over sirolimus drug-eluting stent: An angioscopic study. JACC Cardiovasc Imaging 2009; 2: 616-624.
    • (2009) JACC Cardiovasc Imaging , vol.2 , pp. 616-624
    • Higo, T.1    Ueda, Y.2    Oyabu, J.3    Okada, K.4    Nishio, M.5    Hirata, A.6
  • 7
    • 80052329078 scopus 로고    scopus 로고
    • Neointimal coverage and stent strut apposition six months after implantation of a paclitaxel eluting stent in acute coronary syndromes: An optical coherence tomography study
    • E-pub ahead of print
    • Davlouros P, Nikokiris G, Karantalis V, Mavronasiou E, Xanthopoulou I, Damelou A, et al. Neointimal coverage and stent strut apposition six months after implantation of a paclitaxel eluting stent in acute coronary syndromes: An optical coherence tomography study. Int J Cardiol 2010 [E-pub ahead of print].
    • (2010) Int J Cardiol
    • Davlouros, P.1    Nikokiris, G.2    Karantalis, V.3    Mavronasiou, E.4    Xanthopoulou, I.5    Damelou, A.6
  • 8
    • 73349096901 scopus 로고    scopus 로고
    • Long-term follow-up of neointimal coverage of sirolimus-eluting stents: Evaluation with optical coherence tomography
    • Ishigami K, Uemura S, Morikawa Y, Soeda T, Okayama S, Nishida T, et al. Long-term follow-up of neointimal coverage of sirolimus-eluting stents: Evaluation with optical coherence tomography. Circ J 2009; 73: 2300-2307.
    • (2009) Circ J , vol.73 , pp. 2300-2307
    • Ishigami, K.1    Uemura, S.2    Morikawa, Y.3    Soeda, T.4    Okayama, S.5    Nishida, T.6
  • 9
    • 67649867101 scopus 로고    scopus 로고
    • Delayed neointimalization on sirolimus-eluting stents: 6-month and 12-month follow up by optical coherence tomography
    • Katoh H, Shite J, Shinke T, Matsumoto D, Tanino Y, Ogasawara D, et al. Delayed neointimalization on sirolimus-eluting stents: 6-month and 12-month follow up by optical coherence tomography. Circ J 2009; 73: 1033-1037.
    • (2009) Circ J , vol.73 , pp. 1033-1037
    • Katoh, H.1    Shite, J.2    Shinke, T.3    Matsumoto, D.4    Tanino, Y.5    Ogasawara, D.6
  • 10
    • 75749123502 scopus 로고    scopus 로고
    • Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxeleluting stents using optical coherence tomography at 9 months after implantation
    • Kim JS, Kim TH, Fan C, Lee JM, Kim W, Ko YG, et al. Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxeleluting stents using optical coherence tomography at 9 months after implantation. Circ J 2010; 74: 320-326.
    • (2010) Circ J , vol.74 , pp. 320-326
    • Kim, J.S.1    Kim, T.H.2    Fan, C.3    Lee, J.M.4    Kim, W.5    Ko, Y.G.6
  • 11
    • 34147126986 scopus 로고    scopus 로고
    • Are drug-eluting stents associated with a higher rate of late thrombosis than bare metal stents? Late stent thrombosis: A nuisance in both bare metal and drug-eluting stents
    • discussion 1439
    • Serruys PW, Daemen J. Are drug-eluting stents associated with a higher rate of late thrombosis than bare metal stents? Late stent thrombosis: A nuisance in both bare metal and drug-eluting stents. Circulation 2007; 115: 1433-1439; discussion 1439.
    • (2007) Circulation , vol.115 , pp. 1433-1439
    • Serruys, P.W.1    Daemen, J.2
  • 12
    • 65549161443 scopus 로고    scopus 로고
    • One step forward and two steps back with drug-eluting-stents: From preventing restenosis to causing late thrombosis and nouveau atherosclerosis
    • Nakazawa G, Vorpahl M, Finn AV, Narula J, Virmani R. One step forward and two steps back with drug-eluting-stents: From preventing restenosis to causing late thrombosis and nouveau atherosclerosis. JACC Cardiovasc Imaging 2009; 2: 625-628.
    • (2009) JACC Cardiovasc Imaging , vol.2 , pp. 625-628
    • Nakazawa, G.1    Vorpahl, M.2    Finn, A.V.3    Narula, J.4    Virmani, R.5
  • 14
    • 77955552822 scopus 로고    scopus 로고
    • Very late clinical cardiac event after bms implantation: In vivo optical coherence tomography examination
    • Kashiwagi M, Kitabata H, Tanaka A, Okochi K, Ishibashi K, Komukai K, et al. Very late clinical cardiac event after bms implantation: In vivo optical coherence tomography examination. JACC Cardiovasc Imaging 2010; 3: 525-527.
    • (2010) JACC Cardiovasc Imaging , vol.3 , pp. 525-527
    • Kashiwagi, M.1    Kitabata, H.2    Tanaka, A.3    Okochi, K.4    Ishibashi, K.5    Komukai, K.6
  • 15
    • 77954740470 scopus 로고    scopus 로고
    • Development of lipid-rich plaque inside bare metal stent: Possible mechanism of late stent thrombosis? An optical coherence tomography study
    • Hou J, Qi H, Zhang M, Ma L, Liu H, Han Z, et al. Development of lipid-rich plaque inside bare metal stent: Possible mechanism of late stent thrombosis? An optical coherence tomography study. Heart 2010; 96: 1187-1190.
    • (2010) Heart , vol.96 , pp. 1187-1190
    • Hou, J.1    Qi, H.2    Zhang, M.3    Ma, L.4    Liu, H.5    Han, Z.6
  • 16
    • 79955043803 scopus 로고    scopus 로고
    • Neointimal tissue rupture as a mechanism of myocardial infarction very late following implantation of bare metal stents: Insights from optical coherence tomography
    • Davlouros PA, Karantalis V, Mavronassiou E, Alexopoulos D. Neointimal tissue rupture as a mechanism of myocardial infarction very late following implantation of bare metal stents: Insights from optical coherence tomography. Int J Cardiol 2011; 148: 348-349.
    • (2011) Int J Cardiol , vol.148 , pp. 348-349
    • Davlouros, P.A.1    Karantalis, V.2    Mavronassiou, E.3    Alexopoulos, D.4
  • 18
    • 50449104976 scopus 로고    scopus 로고
    • Safety and usefulness of non-occlusion image acquisition technique for optical coherence tomography
    • Kataiwa H, Tanaka A, Kitabata H, Imanishi T, Akasaka T. Safety and usefulness of non-occlusion image acquisition technique for optical coherence tomography. Circ J 2008; 72: 1536-1537.
    • (2008) Circ J , vol.72 , pp. 1536-1537
    • Kataiwa, H.1    Tanaka, A.2    Kitabata, H.3    Imanishi, T.4    Akasaka, T.5
  • 19
    • 44149100010 scopus 로고    scopus 로고
    • From bench to bedside: A novel technique of acquiring oct images
    • Prati F, Cera M, Ramazzotti V, Imola F, Giudice R, Giudice M, et al. From bench to bedside: A novel technique of acquiring oct images. Circ J 2008; 72: 839-843.
    • (2008) Circ J , vol.72 , pp. 839-843
    • Prati, F.1    Cera, M.2    Ramazzotti, V.3    Imola, F.4    Giudice, R.5    Giudice, M.6
  • 20
    • 78951483028 scopus 로고    scopus 로고
    • Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study
    • Kim JS, Fan C, Choi D, Jang IK, Lee JM, Kim TH, et al. Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study. Int J Cardiol 2009; 146: 341-346.
    • (2009) Int J Cardiol , vol.146 , pp. 341-346
    • Kim, J.S.1    Fan, C.2    Choi, D.3    Jang, I.K.4    Lee, J.M.5    Kim, T.H.6
  • 21
    • 65549111877 scopus 로고    scopus 로고
    • Local determinants of thrombus formation following sirolimus-eluting stent implantation assessed by optical coherence tomography
    • Otake H, Shite J, Ako J, Shinke T, Tanino Y, Ogasawara D, et al. Local determinants of thrombus formation following sirolimus-eluting stent implantation assessed by optical coherence tomography. JACC Cardiovasc Interv 2009; 2: 459-466.
    • (2009) JACC Cardiovasc Interv , vol.2 , pp. 459-466
    • Otake, H.1    Shite, J.2    Ako, J.3    Shinke, T.4    Tanino, Y.5    Ogasawara, D.6
  • 22
    • 72549090920 scopus 로고    scopus 로고
    • Appearance of lipid-laden intima and neovascularization after implantation of bare-metal stents extended late-phase observation by intracoronary optical coherence tomography
    • Takano M, Yamamoto M, Inami S, Murakami D, Ohba T, Seino Y, et al. Appearance of lipid-laden intima and neovascularization after implantation of bare-metal stents extended late-phase observation by intracoronary optical coherence tomography. J Am Coll Cardiol 2009; 55: 26-32.
    • (2009) J Am Coll Cardiol , vol.55 , pp. 26-32
    • Takano, M.1    Yamamoto, M.2    Inami, S.3    Murakami, D.4    Ohba, T.5    Seino, Y.6
  • 23
    • 36348952607 scopus 로고    scopus 로고
    • Outcomes of stent thrombosis and restenosis during extended follow- up of patients treated with bare-metal coronary stents
    • Doyle B, Rihal CS, O'Sullivan CJ, Lennon RJ, Wiste HJ, Bell M, et al. Outcomes of stent thrombosis and restenosis during extended follow- up of patients treated with bare-metal coronary stents. Circulation 2007; 116: 2391-2398.
    • (2007) Circulation , vol.116 , pp. 2391-2398
    • Doyle, B.1    Rihal, C.S.2    O'Sullivan, C.J.3    Lennon, R.J.4    Wiste, H.J.5    Bell, M.6
  • 25
    • 12144288756 scopus 로고    scopus 로고
    • Pathological analyses of long-term intracoronary palmaz-schatz stenting; is its efficacy permanent
    • Inoue K, Abe K, Ando K, Shirai S, Nishiyama K, Nakanishi M, et al. Pathological analyses of long-term intracoronary palmaz-schatz stenting; is its efficacy permanent? Cardiovasc Pathol 2004; 13: 109-115.
    • (2004) Cardiovasc Pathol , vol.13 , pp. 109-115
    • Inoue, K.1    Abe, K.2    Ando, K.3    Shirai, S.4    Nishiyama, K.5    Nakanishi, M.6
  • 27
    • 33745233024 scopus 로고    scopus 로고
    • Pathology of drug-eluting stents in humans: Delayed healing and late thrombotic risk
    • Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, et al. Pathology of drug-eluting stents in humans: Delayed healing and late thrombotic risk. J Am Coll Cardiol 2006; 48: 193-202.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 193-202
    • Joner, M.1    Finn, A.V.2    Farb, A.3    Mont, E.K.4    Kolodgie, F.D.5    Ladich, E.6
  • 28
    • 17844373254 scopus 로고    scopus 로고
    • Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents
    • Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, et al. Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 2005; 293: 2126-2130.
    • (2005) JAMA , vol.293 , pp. 2126-2130
    • Iakovou, I.1    Schmidt, T.2    Bonizzoni, E.3    Ge, L.4    Sangiorgi, G.M.5    Stankovic, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.