-
1
-
-
68949192785
-
Preoperative measurement of thickness of cutaneous melanoma using high-resolution 20 MHz ultrasound imaging: A monocenter prospective study and systematic review of the literature
-
Machet L, Belot V, Naouri M, et al: Preoperative measurement of thickness of cutaneous melanoma using high-resolution 20 MHz ultrasound imaging: a monocenter prospective study and systematic review of the literature. Ultrasound Med Biol 2009; 35: 1411-1420.
-
(2009)
Ultrasound Med Biol
, vol.35
, pp. 1411-1420
-
-
MacHet, L.1
Belot, V.2
Naouri, M.3
-
2
-
-
69949104560
-
Preoperative assessment of cutaneous melanoma thickness using 10-MHz sonography
-
Vilana R, Puig S, Sanchez M, et al: Preoperative assessment of cutaneous melanoma thickness using 10-MHz sonography. AJR Am J Roentgenol 2009; 193: 639-643.
-
(2009)
AJR Am J Roentgenol
, vol.193
, pp. 639-643
-
-
Vilana, R.1
Puig, S.2
Sanchez, M.3
-
3
-
-
34347343802
-
Preoperative ultrasonic assessment of thin melanocytic skin lesions using a 100-MHz ultrasound transducer: A comparative study
-
DOI 10.1111/j.1524-4725.2007.33175.x
-
Gambichler T, Moussa G, Bahrenberg K, et al: Preoperative ultrasound assessment of thin melanocytic skin lesions using a 100-MHz ultrasound transducer: a comparative study. Dermatol Surg 2007; 33: 818-824. (Pubitemid 47013522)
-
(2007)
Dermatologic Surgery
, vol.33
, Issue.7
, pp. 818-824
-
-
Gambichler, T.1
Moussa, G.2
Bahrenberg, K.3
Vogt, M.4
Ermert, H.5
Weyhe, D.6
Altmeyer, P.7
Hoffmann, K.8
-
4
-
-
0028525764
-
Preoperative ultrasonographic measurement of melanoma thickness with 20 MHz probe
-
Pennasilico G, Santini A, Bono R, et al: Preoperative ultrasonographic measurement of melanoma thickness with 20 MHz probe. Radiol Med 1994; 88: 388-391.
-
(1994)
Radiol Med
, vol.88
, pp. 388-391
-
-
Pennasilico, G.1
Santini, A.2
Bono, R.3
-
5
-
-
0026753306
-
El Gammel S et al: Malignant melanoma in 20-MHz B scan sonography
-
Hoffmann K, Jung J, el Gammel S, et al: Malignant melanoma in 20-MHz B scan sonography. Dermatology 1992; 185: 49-55.
-
(1992)
Dermatology
, vol.185
, pp. 49-55
-
-
Hoffmann, K.1
Jung, J.2
-
6
-
-
0025331425
-
WERTIGKEIT DER HOCHAUFLOSENDEN SONOGRAPHIE FUR DIE BESTIMMUNG DES VERTIKALEN TUMORDURCHMESSERS BEIM MALIGNEN MELANOM DER HAUT
-
Gassenmeier G, Kiesewetter F, Schell H, et al: Value of high resolution ultrasound in determination of vertical tumor thickness in malignant melanoma of the skin (in German). Hautarzt 1990; 41: 360-364. (Pubitemid 20241388)
-
(1990)
Hautarzt
, vol.41
, Issue.7
, pp. 360-364
-
-
Gassenmaier, G.1
Kiesewetter, F.2
Schell, H.3
Zinner, M.4
-
7
-
-
0021248926
-
Preoperative ultrasonic measurements of the thickness of cutaneous malignant melanoma
-
Shafir R, Itzchaky Y, Heyman Z: Preoperative ultrasonic measurements of thickness of cutaneous malignant melanoma. J Ultrasound Med 1984; 3: 205-208. (Pubitemid 14116357)
-
(1984)
Journal of Ultrasound in Medicine
, vol.3
, Issue.5
, pp. 205-208
-
-
Shafir, R.1
Itzchak, Y.2
Heyman, Z.3
-
8
-
-
0031456997
-
Optical coherence tomography of the human skin
-
DOI 10.1016/S0190-9622(97)70072-0
-
Welzel J, Lankenau E, Birngruber R, et al: Optical coherence tomography of the human skin. J Am Acad Dermatol 1997; 37: 958-963. (Pubitemid 28016626)
-
(1997)
Journal of the American Academy of Dermatology
, vol.37
, Issue.6
, pp. 958-963
-
-
Welzel, J.1
Lankenau, E.2
Birngruber, R.3
Engelhardt, R.4
-
9
-
-
0033983388
-
In vivo optical coherence tomography imaging of human skin: Norm and pathology
-
DOI 10.1034/j.1600-0846.2000.006001006.x
-
Gladkova ND, Petrova GA, Nikulin NK, et al: In vivo optical coherence tomography imaging of human skin: norm and pathology. Skin Res Technol 2000; 6: 6-16. (Pubitemid 30077135)
-
(2000)
Skin Research and Technology
, vol.6
, Issue.1
, pp. 6-16
-
-
Gladkova, N.D.1
Petrova, G.A.2
Nikulin, N.K.3
Radenska-Lopovok, S.G.4
Snopova, L.B.5
Chumakov, Yu.P.6
Nasonova, V.A.7
Gelikonov, V.M.8
Gelikonov, G.V.9
Kuranov, R.V.10
Sergeev, A.M.11
Feldchtein, F.I.12
-
10
-
-
0142151731
-
Instruments and new technologies for the in vivo diagnosis of melanoma
-
DOI 10.1016/S0190-9622(03)02470-8
-
Marghoob AA, Swindle LD, Moricz CZ, et al: Instruments and new technologies for the in vivo diagnosis of melanoma. J Am Acad Dermatol 2003; 49: 777-797. (Pubitemid 37314865)
-
(2003)
Journal of the American Academy of Dermatology
, vol.49
, Issue.5
, pp. 777-797
-
-
Marghoob, A.A.1
Swindle, L.D.2
Moricz, C.Z.M.3
Sanchez Negron, F.A.4
Slue, B.5
Halpern, A.C.6
Kopf, A.W.7
-
11
-
-
79955697131
-
High-resolution ultrasound combined with power Doppler sonography can reduce the number of sentinel lymph node biopsies in cutaneous melanoma
-
Hinz T, Wilsmann-Theis D, Buchner A, et al: High-resolution ultrasound combined with power Doppler sonography can reduce the number of sentinel lymph node biopsies in cutaneous melanoma. Dermatology 2011; 222: 180-188.
-
(2011)
Dermatology
, vol.222
, pp. 180-188
-
-
Hinz, T.1
Wilsmann-Theis, D.2
Buchner, A.3
-
12
-
-
64749116494
-
Strategies for early melanoma detection: Approaches to the patient with nevi
-
Goodson AG, Grossman D: Strategies for early melanoma detection: approaches to the patient with nevi. J Am Acad Dermatol 2009; 60: 719-735.
-
(2009)
J Am Acad Dermatol
, vol.60
, pp. 719-735
-
-
Goodson, A.G.1
Grossman, D.2
-
13
-
-
80053564101
-
Optical coherence tomography in dermatology: Technical and clinical aspects
-
Gambichler T, Jaedicke V, Terras S: Optical coherence tomography in dermatology: technical and clinical aspects. Arch Dermatol Res 2011; 303: 457-473.
-
(2011)
Arch Dermatol Res
, vol.303
, pp. 457-473
-
-
Gambichler, T.1
Jaedicke, V.2
Terras, S.3
-
14
-
-
1542507092
-
Changes in function and morphology of normal human skin: Evaluation using optical coherence tomography
-
DOI 10.1111/j.1365-2133.2004.05810.x
-
Welzel J, Reinhardt C, Lankenau E, et al: Changes in function and morphology of normal human skin: evaluation using optical coherence tomography. Br J Dermatol 2004; 150: 220-225. (Pubitemid 38352458)
-
(2004)
British Journal of Dermatology
, vol.150
, Issue.2
, pp. 220-225
-
-
Welzel, J.1
Reinhardt, C.2
Lankenau, E.3
Winter, C.4
Wolff, H.H.5
-
15
-
-
46049098793
-
Morphology and epidermal thickness of normal skin imaged by optical coherence tomography
-
DOI 10.1159/000118508
-
Mogensen M, Morsy HA, Thrane L, et al: Morphology and epidermal thickness of normal skin imaged by optical coherence tomography. Dermatology 2008; 217: 14-20. (Pubitemid 351896562)
-
(2008)
Dermatology
, vol.217
, Issue.1
, pp. 14-20
-
-
Mogensen, M.1
Morsy, H.A.2
Thrane, L.3
Jemec, G.B.E.4
-
16
-
-
0033035135
-
Optical coherence tomography in dermatology
-
DOI 10.1111/j.1600-0846.1999.tb00120.x
-
Pagnoni A, Knüttel A, Welker P, et al: Optical coherence tomography in dermatology. Skin Res Technol 1999; 5: 83-87. (Pubitemid 29299103)
-
(1999)
Skin Research and Technology
, vol.5
, Issue.2
, pp. 83-87
-
-
Pagnoni, A.1
Knuettel, A.2
Welker, P.3
Rist, M.4
Stoudemayer, T.5
Kolbe, L.6
Sadiq, I.7
Kligman, A.M.8
-
17
-
-
34147176057
-
Correlation of thickness of basal cell carcinoma by optical coherence tomography in vivo and routine histologic findings: A pilot study
-
DOI 10.1111/j.1524-4725.2007.33088.x
-
Olmedo JM, Warschaw KE, Schmitt JM, et al: Correlation of thickness of basal cell carcinoma by optical coherence tomography in vivo and routine histologic findings: a pilot study. Dermatol Surg 2007; 33: 421-425. (Pubitemid 46570112)
-
(2007)
Dermatologic Surgery
, vol.33
, Issue.4
, pp. 421-425
-
-
Olmedo, J.M.1
Warschaw, K.E.2
Schmitt, J.M.3
Swanson, D.L.4
-
18
-
-
66449105802
-
Assessment of optical coherence tomography imaging in the diagnosis of non-melanoma skin cancer and benign lesions versus normal skin: Observer-blinded evaluation by dermatologists and pathologists
-
Mogensen M, Joergensen T, Nuernberg B, et al: Assessment of optical coherence tomography imaging in the diagnosis of non-melanoma skin cancer and benign lesions versus normal skin: observer-blinded evaluation by dermatologists and pathologists. Dermatol Surg 2009; 35: 965-972.
-
(2009)
Dermatol Surg
, vol.35
, pp. 965-972
-
-
Mogensen, M.1
Joergensen, T.2
Nuernberg, B.3
-
19
-
-
64849088899
-
In vivo thickness measurement of basal cell carcinoma and actinic keratosis with optical coherence tomography and 20-MHz ultrasound
-
Mogensen M, Nuernberg BM, Forman JL, et al: In vivo thickness measurement of basal cell carcinoma and actinic keratosis with optical coherence tomography and 20-MHz ultrasound. Br J Dermatol 2009; 160: 1026-1033.
-
(2009)
Br J Dermatol
, vol.160
, pp. 1026-1033
-
-
Mogensen, M.1
Nuernberg, B.M.2
Forman, J.L.3
-
20
-
-
0346458726
-
Optische Kohärenztomographie versus Ultraschallbiomikroskopie bei Bindehaut- und Lidtumoren
-
DOI 10.1055/s-2003-812563
-
Buchwald HJ, Müller A, Kampmeier J, et al: Optical coherence tomography versus ultrasound biomicroscopy of conjunctival and eyelid lesions. Klin Monbl Augenheilkd 2003; 220: 822-829. (Pubitemid 38084163)
-
(2003)
Klinische Monatsblatter fur Augenheilkunde
, vol.220
, Issue.12
, pp. 822-829
-
-
Buchwald, H.-J.1
Muller, A.2
Kampmeier, J.3
Lang, G.K.4
-
21
-
-
34548539849
-
Characterization of benign and malignant melanocytic skin lesions using optical coherence tomography in vivo
-
DOI 10.1016/j.jaad.2007.05.029, PII S0190962207008985
-
Gambichler T, Regeniter P, Bechara FG, et al: Characterization of benign and malignant melanocytic skin lesions using optical coherence tomography in vivo. J Am Acad Dermatol 2007; 57: 629-637. (Pubitemid 47384930)
-
(2007)
Journal of the American Academy of Dermatology
, vol.57
, Issue.4
, pp. 629-637
-
-
Gambichler, T.1
Regeniter, P.2
Bechara, F.G.3
Orlikov, A.4
Vasa, R.5
Moussa, G.6
Stucker, M.7
Altmeyer, P.8
Hoffmann, K.9
-
22
-
-
79954999133
-
Comparison of pulsed photothermal radiometry, optical coherence tomography and ultrasound for melanoma thickness measurement in PDMS tissue phantoms
-
Wang T, Mallidi S, Qiu J, et al: Comparison of pulsed photothermal radiometry, optical coherence tomography and ultrasound for melanoma thickness measurement in PDMS tissue phantoms. J Biophotonics 2010; 4: 335-344.
-
(2010)
J Biophotonics
, vol.4
, pp. 335-344
-
-
Wang, T.1
Mallidi, S.2
Qiu, J.3
-
23
-
-
34247279232
-
Validation of optical coherence tomography in vivo using cryostat histology
-
DOI 10.1088/0031-9155/52/5/N01, PII S0031915507301991, N01
-
Gambichler T, Moussa G, Regeniter P, et al: Validation of optical coherence tomography in vivo using cryostat histology. Phys Med Biol 2007; 52: N75-N85. (Pubitemid 46646403)
-
(2007)
Physics in Medicine and Biology
, vol.52
, Issue.5
-
-
Gambichler, T.1
Moussa, G.2
Regeniter, P.3
Kasseck, C.4
Hofmann, M.R.5
Bechara, F.G.6
Sand, M.7
Altmeyer, P.8
Hoffmann, K.9
-
24
-
-
77951774162
-
Anatomical detection of inflammatory changes associated with plantar warts by ultrasound
-
Wortsman X, Jemec GB, Sazunic I: Anatomical detection of inflammatory changes associated with plantar warts by ultrasound. Dermatology 2010; 220: 213-217.
-
(2010)
Dermatology
, vol.220
, pp. 213-217
-
-
Wortsman, X.1
Jemec, G.B.2
Sazunic, I.3
|