메뉴 건너뛰기




Volumn 1, Issue 1, 2008, Pages

Microbubbles detection during cardiopulmonary bypass with transoesophageal echocardiography: A case report

Author keywords

[No Author keywords available]

Indexed keywords


EID: 82255168647     PISSN: 17571626     EISSN: 17571626     Source Type: Journal    
DOI: 10.1186/1757-1626-1-141     Document Type: Article
Times cited : (3)

References (12)
  • 1
    • 0028206123 scopus 로고
    • The impact of microemboli during cardiopulmonary bypass on neuropsychological functioning
    • Pugsley W, Klinger L, Paschalis C., Treasure T, Harrison M, Newman S: The impact of microemboli during cardiopulmonary bypass on neuropsychological functioning. Stroke 1994, 25:1393-9.
    • (1994) Stroke , vol.25 , pp. 1393-1399
    • Pugsley, W.1    Klinger, L.2    Paschalis, C.3    Treasure, T.4    Harrison, M.5    Newman, S.6
  • 2
    • 20344368007 scopus 로고    scopus 로고
    • Cognitive dysfunction after cardiac surgery: Revisiting etiology
    • Grocott HP, Homi HM, Puskas F: Cognitive dysfunction after cardiac surgery: revisiting etiology. Semin Cardiothorac Vasc Anesth 2005, 9(2):123-9.
    • (2005) Semin Cardiothorac Vasc Anesth , vol.9 , Issue.2 , pp. 123-129
    • Grocott, H.P.1    Homi, H.M.2    Puskas, F.3
  • 3
    • 0030666567 scopus 로고    scopus 로고
    • Cerebral microembolic signals during cardiopulmonary bypass surgery frequency, time of occurrence, and association with patient and surgical characteristics
    • Brækken S.K., Russell D, Brucher R., Abdelnoor M, Svennevig JL: Cerebral Microembolic Signals During Cardiopulmonary Bypass Surgery Frequency, Time of Occurrence, and Association With Patient and Surgical Characteristics. Stroke 1997, 28:1988-1992.
    • (1997) Stroke , vol.28 , pp. 1988-1992
    • Brækken, S.K.1    Russell, D.2    Brucher, R.3    Abdelnoor, M.4    Svennevig, J.L.5
  • 4
    • 0036330322 scopus 로고    scopus 로고
    • Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial doppler
    • Russell D, Brucher R: Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler. Stroke 2002, 33(8):1975-80.
    • (2002) Stroke , vol.33 , Issue.8 , pp. 1975-1980
    • Russell, D.1    Brucher, R.2
  • 6
    • 27144506167 scopus 로고    scopus 로고
    • Microbubbles: Pathophysiology and clinical implications
    • Barak M, Katz Y: Microbubbles: pathophysiology and clinical implications. Chest 2005, 128(4):2918-32.
    • (2005) Chest , vol.128 , Issue.4 , pp. 2918-2932
    • Barak, M.1    Katz, Y.2
  • 9
    • 0032862581 scopus 로고    scopus 로고
    • ASE/SCA guidelines for performing a comprehensive intraoperative multiplane transesophageal echocardiog-raphy examination: Recommendations of the American society of echocardiography council for intraoperative echocardiography and the society of cardiovascular anesthesiologists task force for certification in perioperative transesophageal echocardiography
    • Shanewise JS, Cheung AT, Aronson S, Stewart W.J., Weiss RL, Mark JB, Savage RM, Sears-Rogan P, Mathew J.P., Quiñones MA, Cahalan M.K., Savino JS: ASE/SCA guidelines for performing a comprehensive intraoperative multiplane transesophageal echocardiog-raphy examination: recommendations of the American Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. Anesth Analg 1999, 89(4):870-84.
    • (1999) Anesth Analg , vol.89 , Issue.4 , pp. 870-884
    • Shanewise, J.S.1    Cheung, A.T.2    Aronson, S.3    Stewart, W.J.4    Weiss, R.L.5    Mark, J.B.6    Savage, R.M.7    Sears-Rogan, P.8    Mathew, J.P.9    Quiñones, M.A.10    Cahalan, M.K.11    Savino, J.S.12
  • 10
    • 33645451063 scopus 로고    scopus 로고
    • Almost perfect concordance between simultaneous transcranial doppler and transesophageal echocardiography in the quantification of right-to-left shunts
    • Belvís R., Leta RG, Martí-Fàbregas J, Cocho D, Carreras F, Pons-Lladó G, Martí-Vilalta JL: Almost perfect concordance between simultaneous transcranial Doppler and transesophageal echocardiography in the quantification of right-to-left shunts. J Neuroimaging 2006, 16(2):133-8.
    • (2006) J Neuroimaging , vol.16 , Issue.2 , pp. 133-138
    • Belvís, R.1    Leta, R.G.2    Martí-Fàbregas, J.3    Cocho, D.4    Carreras, F.5    Pons-Lladó, G.6    Martí-Vilalta, J.L.7
  • 11
    • 0032722193 scopus 로고    scopus 로고
    • Venous air in the bypass circuit: A source of arterial line emboli exacerbated by vacuum-assisted drainage
    • Willcox TW, Mitchell SJ, Gorman DF: Venous air in the bypass circuit: a source of arterial line emboli exacerbated by vacuum-assisted drainage. Ann Thorac Surg 1999, 68(4):1285-9.
    • (1999) Ann Thorac Surg , vol.68 , Issue.4 , pp. 1285-1289
    • Willcox, T.W.1    Mitchell, S.J.2    Gorman, D.F.3
  • 12
    • 32044432107 scopus 로고    scopus 로고
    • Multifrequency transcranial dop-pler for intraoperative automatic detection and characterisation of cerebral microemboli during port-access mitral valve surgery
    • Epub 2005 Nov 8
    • Maselli D, Pizio R, Musumeci F: Multifrequency transcranial Dop-pler for intraoperative automatic detection and characterisation of cerebral microemboli during port-access mitral valve surgery. Interact Cardiovasc Thorac Surg 2006, 5(1):32-5. Epub 2005 Nov 8
    • (2006) Interact Cardiovasc Thorac Surg , vol.5 , Issue.1 , pp. 32-35
    • Maselli, D.1    Pizio, R.2    Musumeci, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.