메뉴 건너뛰기




Volumn 107, Issue 6, 2011, Pages 983-988

Randomized controlled trial of the A.P. Advance, McGrath, and Macintosh laryngoscopes in normal and difficult intubation scenarios: A manikin study

Author keywords

intratracheal; intubation; laryngoscopes; manikins; randomized controlled trial

Indexed keywords

AIRWAY; ANESTHESIST; ARTICLE; AUDIOVISUAL EQUIPMENT; CONTROLLED STUDY; ENDOTRACHEAL INTUBATION; FEMALE; GLOTTIS; HUMAN; HUMAN EXPERIMENT; LARYNGOSCOPE; LARYNGOSCOPY; MALE; PRIORITY JOURNAL; VIDEOLARYNGOSCOPE; VOCAL CORD;

EID: 81855206557     PISSN: 00070912     EISSN: 14716771     Source Type: Journal    
DOI: 10.1093/bja/aer295     Document Type: Article
Times cited : (31)

References (24)
  • 2
    • 58149240273 scopus 로고    scopus 로고
    • Comparison of the Glidescope the McGrath the Airtraq and the Macintosh laryngoscopes in simulated difficult airways
    • Savoldelli GL, Schiffer E, Abegg C, Baeriswyl V, Clergue F, Waeber JL. Comparison of the Glidescope, the McGrath, the Airtraq and the Macintosh laryngoscopes in simulated difficult airways. Anaesthesia 2008; 63: 1358-64
    • (2008) Anaesthesia , vol.63 , pp. 1358-1364
    • Savoldelli, G.L.1    Schiffer, E.2    Abegg, C.3    Baeriswyl, V.4    Clergue, F.5    Waeber, J.L.6
  • 3
    • 70350702956 scopus 로고    scopus 로고
    • A comparison of three videolaryngoscopes: The Macintosh laryngoscope blade reduces but does not replace routine stylet use for intubation in morbidly obese patients
    • Maassen R, Lee R, Hermans B, Marcus M, van Zundert A. A comparison of three videolaryngoscopes: the Macintosh laryngoscope blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients. Anesth Analg 2009; 109: 1560-5
    • (2009) Anesth Analg. , vol.109 , pp. 1560-1565
    • Maassen, R.1    Lee, R.2    Hermans, B.3    Marcus, M.4    Van Zundert, A.5
  • 6
    • 34249798746 scopus 로고    scopus 로고
    • Case series: The McGrathw videolaryngoscope- an initial clinical evaluation
    • Shippey B, Ray D, McKeown D. Case series: the McGrathw videolaryngoscope- an initial clinical evaluation. Can J Anaesth 2007; 54: 307-13
    • (2007) Can. J. Anaesth , vol.54 , pp. 307-313
    • Shippey, B.1    Ray, D.2    McKeown, D.3
  • 7
    • 33846605602 scopus 로고    scopus 로고
    • Complications associated with the use of the Glide- Scope videolaryngoscope
    • Cooper RM. Complications associated with the use of the Glide- Scope videolaryngoscope. Can J Anaesth 2007; 54: 54-7
    • (2007) Can. J. Anaesth , vol.54 , pp. 54-57
    • Cooper, R.M.1
  • 8
    • 34447628687 scopus 로고    scopus 로고
    • Perforation of the soft palate using the GlideScopew videolaryngoscope
    • Cross P, Cytryn J, Cheng KK. Perforation of the soft palate using the GlideScopew videolaryngoscope. Can J Anaesth 2007; 54: 588-9
    • (2007) Can. J. Anaesth , vol.54 , pp. 588-589
    • Cross, P.1    Cytryn, J.2    Cheng, K.K.3
  • 9
    • 34249000358 scopus 로고    scopus 로고
    • Penetrating injury of the soft palate during GlideScopew intubation
    • Hsu WT, Hsu SC, Lee YL, Huang JS, Chen CL. Penetrating injury of the soft palate during GlideScopew intubation. Anesth Analg 2007; 104: 1609
    • (2007) Anesth Analg. , vol.104 , pp. 1609
    • Hsu, W.T.1    Hsu, S.C.2    Lee, Y.L.3    Huang, J.S.4    Chen, C.L.5
  • 10
    • 70149117795 scopus 로고    scopus 로고
    • A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways
    • van Zundert A, Maassen R, Lee R, et al. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways. Anesth Analg 2009; 109: 825-31.
    • (2009) Anesth Analg. , vol.109 , pp. 825-831
    • Van Zundert, A.1    Maassen, R.2    Lee, R.3
  • 11
    • 81855187247 scopus 로고    scopus 로고
    • MacGrath Revision 4.2. Edinburgh, UK: Aircraft Medical
    • MacGrath. McGrath Series 5 Operator's Manual. 2007 Revision 4.2. Edinburgh, UK: Aircraft Medical
    • (2007) McGrath Series 5 Operators Manual
  • 12
    • 77956168055 scopus 로고    scopus 로고
    • Use of a Venner AP Advance videolaryngoscope in a patient with potential cervical spine injury
    • Butchart A, Young P. Use of a Venner AP Advance videolaryngoscope in a patient with potential cervical spine injury. Anaesthesia 2010; 65: 953-4
    • (2010) Anaesthesia , vol.65 , pp. 953-954
    • Butchart, A.1    Young, P.2
  • 13
    • 46249116225 scopus 로고    scopus 로고
    • Preliminary evaluation of a novel videolaryngoscope theMcGrath series 5 in themanagement of difficultand challenging endotracheal intubation Letter
    • O'Leary AM, Sandison MR, Myneni N, Cirilla DJ, Roberts KW, Deane GD. Preliminary evaluation of a novel videolaryngoscope, theMcGrath series 5, in themanagement of difficultand challenging endotracheal intubation. (Letter). J Clin Anesth 2008; 20: 320-1
    • (2008) J. Clin. Anesth , vol.20 , pp. 320-321
    • O'Leary, A.M.1    Sandison, M.R.2    Myneni, N.3    Cirilla, D.J.4    Roberts, K.W.5    Deane, G.D.6
  • 14
    • 74949109706 scopus 로고    scopus 로고
    • Comparison of the performance of four laryngoscopes in a high-fidelity simulator using normal and difficult airway
    • Powell L, Andrzejowski J, Taylor R, Turnbull D. Comparison of the performance of four laryngoscopes in a high-fidelity simulator using normal and difficult airway. Br J Anaesth 2009; 103: 755-60
    • (2009) Br. J. Anaesth , vol.103 , pp. 755-760
    • Powell, L.1    Andrzejowski, J.2    Taylor, R.3    Turnbull, D.4
  • 15
    • 57349173574 scopus 로고    scopus 로고
    • Comparison of the Glidescope the Pentax AWS and the truview EVO2 with the Macintosh laryngoscope in experienced anaesthetists: A manikin study
    • Malik MA, O'Donoghue C, Carney J, Maharaj CH, Harte BH, Laffey JG. Comparison of the Glidescope, the Pentax AWS, and the Truview EVO2 with the Macintosh laryngoscope in experienced anaesthetists: a manikin study. Br J Anaesth 2009; 102: 128-34
    • (2009) Br. J. Anaesth , vol.102 , pp. 128-134
    • Malik, M.A.1    O'Donoghue, C.2    Carney, J.3    Maharaj, C.H.4    Harte, B.H.5    Laffey, J.G.6
  • 16
    • 77950880176 scopus 로고    scopus 로고
    • Comparison of the C-MAC videolaryngoscope with the macintosh glidescope and airtraq laryngoscopes in easy and difficult laryngoscopy scenarios in manikins
    • McElwain J, Malik MA, Harte BH, Flynn NM, Laffey JG. Comparison of the C-MAC videolaryngoscope with the Macintosh, Glidescope, and Airtraq laryngoscopes in easy and difficult laryngoscopy scenarios in manikins. Anaesthesia 2010; 65: 483-9
    • (2010) Anaesthesia , vol.65 , pp. 483-489
    • McElwain, J.1    Malik, M.A.2    Harte, B.H.3    Flynn, N.M.4    Laffey, J.G.5
  • 17
    • 75749136069 scopus 로고    scopus 로고
    • Comparison of the Pentax Airway Scope and McGrath videolaryngoscope with the Macintosh laryngoscope in tracheal intubation by anaesthetists unfamiliar with videolaryngoscopes: A manikin study
    • Sharma DJ, Weightman WM, Travis A. Comparison of the Pentax Airway Scope and McGrath videolaryngoscope with the Macintosh laryngoscope in tracheal intubation by anaesthetists unfamiliar with videolaryngoscopes: a manikin study. Anaesth Intensive Care 2010; 38: 39-42
    • (2010) Anaesth Intensive Care , vol.38 , pp. 39-42
    • Sharma, D.J.1    Weightman, W.M.2    Travis, A.3
  • 18
    • 70350499827 scopus 로고    scopus 로고
    • A comparison of McGrath and Macintosh laryngoscopes in novice users: A manikin study
    • Ray DC, Billington C, Kearns PK, et al. A comparison of McGrath and Macintosh laryngoscopes in novice users: a manikin study. Anaesthesia 2009; 64: 1207-10.
    • (2009) Anaesthesia , vol.64 , pp. 1207-1210
    • Ray, D.C.1    Billington, C.2    Kearns, P.K.3
  • 19
    • 0021701206 scopus 로고
    • Difficult tracheal intubation in obstetrics
    • Cormack RS, Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia 1984; 39: 1105-11
    • (1984) Anaesthesia , vol.39 , pp. 1105-1111
    • Cormack, R.S.1    Lehane, J.2
  • 21
    • 78650658494 scopus 로고    scopus 로고
    • Evaluation of airway equipment: Man or manikin
    • Rai MR, Popat MT. Evaluation of airway equipment: man or manikin? Anaesthesia 2011; 66: 1-9
    • (2011) Anaesthesia , vol.66 , pp. 1-9
    • Rai, M.R.1    Popat, M.T.2
  • 22
    • 0036062653 scopus 로고    scopus 로고
    • Improving learning of a clinical skill: The first years experience of teaching endotracheal intubation in a clinical simulation facility
    • Owen H, Plummer JL. Improving learning of a clinical skill: the first year's experience of teaching endotracheal intubation in a clinical simulation facility. Medical education 2002; 36: 635-42
    • (2002) Medical education , vol.36 , pp. 635-642
    • Owen, H.1    Plummer, J.L.2
  • 23
    • 33947654834 scopus 로고    scopus 로고
    • Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices
    • Jackson KM, Cook TM. Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices. Anaesthesia 2007; 62: 388-93
    • (2007) Anaesthesia , vol.62 , pp. 388-393
    • Jackson, K.M.1    Cook, T.M.2
  • 24
    • 0035108452 scopus 로고    scopus 로고
    • Hawthorne effects and research into professional practice
    • Holden JD. Hawthorne effects and research into professional practice. J Eval Clin Pract 2001; 7: 65-70
    • (2001) J. Eval. Clin. Pract. , vol.7 , pp. 65-70
    • Holden, J.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.