메뉴 건너뛰기




Volumn 42, Issue 6, 2011, Pages 797-802

Single-centre prospective comparison between contrast-enhanced ultrasound and computed tomography angiography after EVAR

Author keywords

Computed tomography; Contrast enhanced ultrasound; Endoleak; Endovascular aneurysm repair

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ARTERY DIAMETER; ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTRAST ENHANCED ULTRASOUND; ECHOGRAPHY; ENDOLEAK; ENDOVASCULAR ANEURYSM REPAIR; FOLLOW UP; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; PRIORITY JOURNAL;

EID: 81755166318     PISSN: 10785884     EISSN: 15322165     Source Type: Journal    
DOI: 10.1016/j.ejvs.2011.09.003     Document Type: Article
Times cited : (71)

References (23)
  • 1
    • 0026321992 scopus 로고
    • Transfemoral intraluminal graft implantation for abdominal aortic aneurysms
    • J.C. Parodi, J.C. Palmaz, and H.D. Barone Transfemoral intraluminal graft implantation for abdominal aortic aneurysms Ann Vasc Surg 5 6 1991 491 499
    • (1991) Ann Vasc Surg , vol.5 , Issue.6 , pp. 491-499
    • Parodi, J.C.1    Palmaz, J.C.2    Barone, H.D.3
  • 3
    • 84993746135 scopus 로고    scopus 로고
    • Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): Randomised controlled trial
    • EVAR Trial Participants Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): randomised controlled trial Lancet 365 9478 2005 2179 2186
    • (2005) Lancet , vol.365 , Issue.9478 , pp. 2179-2186
    • Trial Participants, E.1
  • 5
    • 77952628285 scopus 로고    scopus 로고
    • Long-term outcome of open or endovascular repair of abdominal aortic aneurysm
    • DREAM Study Group
    • J.L. De Bruin, A.F. Baas, J. Buth, M. Prinssen, E.L. Verhoeven, P.W. Cuypers DREAM Study Group Long-term outcome of open or endovascular repair of abdominal aortic aneurysm N Engl J Med 362 20 2010 1881 1889
    • (2010) N Engl J Med , vol.362 , Issue.20 , pp. 1881-1889
    • De Bruin, J.L.1    Baas, A.F.2    Buth, J.3    Prinssen, M.4    Verhoeven, E.L.5    Cuypers, P.W.6
  • 6
    • 3543036969 scopus 로고    scopus 로고
    • Surveillance after endovascular aneurysm repair: Diagnostics, complications, and associated costs
    • M. Prinssen, C.L. Wixon, E. Buskens, and J.D. Blankensteijn Surveillance after endovascular aneurysm repair: diagnostics, complications, and associated costs Ann Vasc Surg 18 4 2004 421 427 (Pubitemid 39014603)
    • (2004) Annals of Vascular Surgery , vol.18 , Issue.4 , pp. 421-427
    • Prinssen, M.1    Wixon, C.L.2    Buskens, E.3    Blankensteijn, J.D.4
  • 7
    • 61349121986 scopus 로고    scopus 로고
    • Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aneurysm repair
    • Y.G. Wolf, B.L. Johnson, B.B. Hill, G.D. Rubin, T.J. Fogarty, and C.K. Zarins Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aneurysm repair J Vasc Surg 49 2009 552 560
    • (2009) J Vasc Surg , vol.49 , pp. 552-560
    • Wolf, Y.G.1    Johnson, B.L.2    Hill, B.B.3    Rubin, G.D.4    Fogarty, T.J.5    Zarins, C.K.6
  • 8
    • 58549097442 scopus 로고    scopus 로고
    • Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: A comparison with computed tomography aortography
    • B.J. Manning, S.M. O'Neill, S.N. Haider, M.P. Colgan, P. Madhavan, and D.J. Moore Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: a comparison with computed tomography aortography J Vasc Surg 49 2009 60 65
    • (2009) J Vasc Surg , vol.49 , pp. 60-65
    • Manning, B.J.1    O'Neill, S.M.2    Haider, S.N.3    Colgan, M.P.4    Madhavan, P.5    Moore, D.J.6
  • 9
    • 63049112353 scopus 로고    scopus 로고
    • Duplex ultrasound as the sole long-term surveillance method post-endovascular aneurysm repair: A safe alternative for stable aneurysms
    • R.A. Chaer, A. Gushchin, R. Rhee, L. Marone, J.S. Cho, and S. Leers Duplex ultrasound as the sole long-term surveillance method post-endovascular aneurysm repair: a safe alternative for stable aneurysms J Vasc Surg 49 4 2009 845 849
    • (2009) J Vasc Surg , vol.49 , Issue.4 , pp. 845-849
    • Chaer, R.A.1    Gushchin, A.2    Rhee, R.3    Marone, L.4    Cho, J.S.5    Leers, S.6
  • 10
    • 20444485179 scopus 로고    scopus 로고
    • Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: A systematic review
    • DOI 10.1583/04-1479R.1
    • R. Ashoke, L.C. Brown, A. Rodway, E. Choke, M.M. Thompson, and R.M. Greenhalg Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: a systematic review J Endovasc Ther 12 3 2005 297 305 (Pubitemid 40828036)
    • (2005) Journal of Endovascular Therapy , vol.12 , Issue.3 , pp. 297-305
    • Ashoke, R.1    Brown, L.C.2    Rodway, A.3    Choke, E.4    Thompson, M.M.5    Greenhalgh, R.M.6    Powell, J.T.7
  • 11
    • 77950063631 scopus 로고    scopus 로고
    • Versus computed tomography for the detection of endoleak after EVAR: Systematic review and bivariate meta-analysis
    • T.A. Mirza, A. Karthikesalingam, D. Jackson, S.R. Walsh, P.J. Holt, and P.D. Hayes Versus computed tomography for the detection of endoleak after EVAR: systematic review and bivariate meta-analysis Eur J Vasc Endovasc Surg 39 2010 418 428
    • (2010) Eur J Vasc Endovasc Surg , vol.39 , pp. 418-428
    • Mirza, T.A.1    Karthikesalingam, A.2    Jackson, D.3    Walsh, S.R.4    Holt, P.J.5    Hayes, P.D.6
  • 12
    • 19044393090 scopus 로고    scopus 로고
    • Ad hoc committee for standardized reporting practices in vascular surgery of the Society Vascular Surgery/American Association for Vascular Surgery. Reporting standards for endovascular aortic aneurysm repair
    • E.L. Chaikof, J.D. Blankensteijn, P.L. Harris, G.H. White, C.K. Zarins, and V.M. Bernhard Ad hoc committee for standardized reporting practices in vascular surgery of the Society Vascular Surgery/American Association for Vascular Surgery. Reporting standards for endovascular aortic aneurysm repair J Vasc Surg 35 5 2002 1048 1060
    • (2002) J Vasc Surg , vol.35 , Issue.5 , pp. 1048-1060
    • Chaikof, E.L.1    Blankensteijn, J.D.2    Harris, P.L.3    White, G.H.4    Zarins, C.K.5    Bernhard, V.M.6
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • J.M. Bland, and D.G. Altman Statistical methods for assessing agreement beteen two methods of clinical measurement Lancet 1 1986 307 310 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 0345073276 scopus 로고    scopus 로고
    • Leakages after endovascular repair of aortic aneurysms: Classification based on findings at CT, angiography, and radiography
    • J. Gorich, N. Rilinger, R. Sokiranski, K.H. Orend, C. Ermis, and S.C. Krämer Leakages after endovascular repair of aortic aneurysms: classification based on findings at CT, angiography, and radiography Radiology 213 3 1999 767 772
    • (1999) Radiology , vol.213 , Issue.3 , pp. 767-772
    • Gorich, J.1    Rilinger, N.2    Sokiranski, R.3    Orend, K.H.4    Ermis, C.5    Krämer, S.C.6
  • 15
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • D.J. Brenner, and E.J. Hall Computed tomography - an increasing source of radiation exposure N Engl J Med 357 2007 2277 2284 (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 16
    • 77950666880 scopus 로고    scopus 로고
    • Estimating risk associated with radiation exposure during follow-up after endovascular aortic repair (EVAR)
    • H.A. White, and S. Macdonald Estimating risk associated with radiation exposure during follow-up after endovascular aortic repair (EVAR) J Cardiovasc Surg 51 2010 95 104
    • (2010) J Cardiovasc Surg , vol.51 , pp. 95-104
    • White, H.A.1    MacDonald, S.2
  • 17
    • 44349101844 scopus 로고    scopus 로고
    • Comparison of the effects of open and endovascular aortic aneurysm repair on long-term renal function using chronic kidney disease staging based on glomerular filtration rate
    • DOI 10.1016/j.jvs.2008.01.039, PII S0741521408001766
    • J.L. Mills Sr, S.T. Duong, L.R. Leon Jr. , K.R. Goshima, D.M. Ihnat, and C.S. Wendel Comparison of the effects of open and endovascular aortic aneurysm repair on long-term renal function using chronic kidney disease staging based on glomerular filtration rate J Vasc Surg 47 6 2008 1141 1149 (Pubitemid 351734609)
    • (2008) Journal of Vascular Surgery , vol.47 , Issue.6 , pp. 1141-1149
    • Mills Sr., J.L.1    Duong, S.T.2    Leon Jr., L.R.3    Goshima, K.R.4    Ihnat, D.M.5    Wendel, C.S.6    Gruessner, A.7
  • 18
    • 39149088018 scopus 로고    scopus 로고
    • Renal consequences of endovascular abdominal aortic aneurysm repair
    • DOI 10.1583/07-2299.1
    • S.R. Walsh, T.Y. Tang, and J.R. Boyle Renal consequences of endovascular abdominal aortic aneurysm repair J Endovasc Ther 15 1 2008 73 82 (Pubitemid 351252235)
    • (2008) Journal of Endovascular Therapy , vol.15 , Issue.1 , pp. 73-82
    • Walsh, S.R.1    Tang, T.Y.2    Boyle, J.R.3
  • 19
    • 79651470001 scopus 로고    scopus 로고
    • Prospective comparative analysis of color-doppler ultrasound, contrast-enhanced ultrasound, computer tomography and magnetic resonance in detecting endoleak after endovascular abdominal aortic aneurysm repair
    • V. Cantisani, P. Ricci, H. Grazhdani, A. Napoli, F. Fanelli, and C. Catalano Prospective comparative analysis of color-doppler ultrasound, contrast-enhanced ultrasound, computer tomography and magnetic resonance in detecting endoleak after endovascular abdominal aortic aneurysm repair Eur J Vasc Endovasc Surg 41 2 2011 186 192
    • (2011) Eur J Vasc Endovasc Surg , vol.41 , Issue.2 , pp. 186-192
    • Cantisani, V.1    Ricci, P.2    Grazhdani, H.3    Napoli, A.4    Fanelli, F.5    Catalano, C.6
  • 20
    • 77952196893 scopus 로고    scopus 로고
    • Ultrasound-determined diameter measurements are more accurate than axial computed tomography after endovascular aortic aneurysm repair
    • S.M. Han, K. Patel, V.L. Rowe, S. Perese, A. Bond, and F.A. Weaver Ultrasound-determined diameter measurements are more accurate than axial computed tomography after endovascular aortic aneurysm repair J Vasc Surg 51 2010 1381 1389
    • (2010) J Vasc Surg , vol.51 , pp. 1381-1389
    • Han, S.M.1    Patel, K.2    Rowe, V.L.3    Perese, S.4    Bond, A.5    Weaver, F.A.6
  • 21
    • 0033004450 scopus 로고    scopus 로고
    • Effect of US contrast agents on spectral velocities: In vitro evaluation
    • M.L. Melany, E.G. Grant, S. Farooki, D. McElroy, and C. Kimme-Smith Effect of US contrast agents on spectral velocities: in vitro evaluation Radiology 211 2 1999 427 431 (Pubitemid 29206811)
    • (1999) Radiology , vol.211 , Issue.2 , pp. 427-431
    • Melany, M.L.1    Grant, E.C.2    Farooki, S.3    McElroy, D.4    Kimme-Smith, C.5
  • 22
    • 77956632925 scopus 로고    scopus 로고
    • Contrast-enhanced ultrasound versus computed tomographic angiography for surveillance of endovascular abdominal aortic aneurysm repair
    • J.A. Ten Bosch, E.V. Rouwet, C.T.H. Peters, L. Jansen, H.J.M. Verhagen, and M.H. Prins Contrast-enhanced ultrasound versus computed tomographic angiography for surveillance of endovascular abdominal aortic aneurysm repair J Vasc Interv Radiol 21 2010 638 643
    • (2010) J Vasc Interv Radiol , vol.21 , pp. 638-643
    • Ten Bosch, J.A.1    Rouwet, E.V.2    Peters, C.T.H.3    Jansen, L.4    Verhagen, H.J.M.5    Prins, M.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.