Volumn 32, Issue 10, 2011, Pages 1783-1788

Experimental study and optimization of scan parameters that influence radiation dose in temporal bone high-resolution multidetector row CT

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CADAVER; COLLIMATOR; DIAGNOSTIC IMAGING; DIAGNOSTIC VALUE; DOSIMETRY; ELECTRIC POTENTIAL; EXPERIMENTAL STUDY; GEOMETRY; HIGH RESOLUTION COMPUTER TOMOGRAPHY; HUMAN; HUMAN TISSUE; IMAGE QUALITY; IMAGE RECONSTRUCTION; INTERNAL AUDITORY CANAL; MULTIDETECTOR COMPUTED TOMOGRAPHY; RADIATION DOSE; TEMPORAL BONE;

EID: 81555226649     PISSN: 01956108     EISSN: 1936959X     Source Type: Journal    
DOI: 10.3174/ajnr.A2609     Document Type: Article
Times cited : (13)

References (18)
  • 1
    • 41949123776 scopus 로고    scopus 로고
    • Delineation of temporal bone anatomy: Feasibility of low-dose 64-row CT in regard to image quality
    • Lutz J, Jäger V, Hempel MJ, et al. Delineation of temporal bone anatomy: feasibility of low-dose 64-row CT in regard to image quality. Eur Radiol 2007;17:2638-45
    • (2007) Eur Radiol , vol.17 , pp. 2638-2645
    • Lutz, J.1    Jäger, V.2    Hempel, M.J.3
  • 2
    • 76749137626 scopus 로고    scopus 로고
    • Radiation dose to the lens using different temporal bone CT scanning protocols
    • Niu Y, Wang Z, Liu Y, et al. Radiation dose to the lens using different temporal bone CT scanning protocols. AJNR Am J Neuroradiol 2010;31:226-29
    • (2010) AJNR Am J Neuroradiol , vol.31 , pp. 226-229
    • Niu, Y.1    Wang, Z.2    Liu, Y.3
  • 4
    • 0036336399 scopus 로고    scopus 로고
    • Primary radiation outside the imaged volume of a multislice helical CT scan
    • Nicholson R, Fetherston S. Primary radiation outside the imaged volume of a multislice helical CT scan. Br J Radiol 2002;75:518-22 (Pubitemid 34863408)
    • (2002) British Journal of Radiology , vol.75 , Issue.894 , pp. 518-522
    • Nicholson, R.1    Fetherston, S.2
  • 5
    • 0034330627 scopus 로고    scopus 로고
    • Multisection CT: Scanning techniques and clinical applications
    • Rydberg J, Buckwalter KA, Caldemeyer KS, et al. Multisection CT: scanning techniques and clinical applications. Radiographics 2000;20:1787-806
    • (2000) Radiographics , vol.20 , pp. 1787-1806
    • Rydberg, J.1    Buckwalter, K.A.2    Caldemeyer, K.S.3
  • 6
    • 40049109570 scopus 로고    scopus 로고
    • Managing patient dose in multi-detector computed tomography (MDCT)
    • ICRP, ICRP Publication 102
    • ICRP, 2007. Managing patient dose in multi-detector computed tomography (MDCT). ICRP Publication 102, Ann. ICRP 37(1)
    • (2007) Ann. ICRP , vol.37 , Issue.1
  • 7
    • 84859746074 scopus 로고    scopus 로고
    • CT dose optimization
    • Accessed December 12, 2008
    • Goodman-Mumma C. CT dose optimization. Medical Imaging http://www.medicalimagingmag.com/issues/articles/2006-06-01.asp. Accessed December 12, 2008
    • Medical Imaging
    • Goodman-Mumma, C.1
  • 8
    • 67949094410 scopus 로고    scopus 로고
    • New radiation dose saving technologies for 256-slice cardiac computed tomography angiography
    • Walker MJ, Olszewski ME, Desai MY, et al. New radiation dose saving technologies for 256-slice cardiac computed tomography angiography. Int J Cardiovasc Imaging 2009;25:189-99
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 189-199
    • Walker, M.J.1    Olszewski, M.E.2    Desai, M.Y.3
  • 9
    • 27744559376 scopus 로고    scopus 로고
    • Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: Phantom study
    • DOI 10.1148/radiol.2373041643
    • Funama Y, Awai K, Nakayama Y, et al. Radiation dose reduction without degradation of low contrast detectability at abdominal multisection CT with a low-tube-voltage technique: phantom study. Radiology 2005;237:905-10 (Pubitemid 41636380)
    • (2005) Radiology , vol.237 , Issue.3 , pp. 905-910
    • Funama, Y.1    Awai, K.2    Nakayama, Y.3    Kakei, K.4    Nagasue, N.5    Shimamura, M.6    Sato, N.7    Sultana, S.8    Morishita, S.9    Yamashita, Y.10
  • 10
    • 0033735138 scopus 로고    scopus 로고
    • Technique factors and image quality as functions of patient weight at abdominal CT
    • Huda W, Scalzetti EM, Levin G. Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 2000;217:430-35
    • (2000) Radiology , vol.217 , pp. 430-435
    • Huda, W.1    Scalzetti, E.M.2    Levin, G.3
  • 12
    • 7044228012 scopus 로고    scopus 로고
    • Radiation dose and image quality in pediatric CT: Effect of technical factors and phantom size and shape
    • DOI 10.1148/radiol.2332032107
    • Siegel MJ, Schmidt B, Bradley D, et al. Radiation dose and image quality in paediatric CT: effect of technical factors and phantom size and shape. Radiology 2004;233:515-22 (Pubitemid 39423813)
    • (2004) Radiology , vol.233 , Issue.2 , pp. 515-522
    • Siegel, M.J.1    Schmidt, B.2    Bradley, D.3    Suess, C.4    Hildebolt, C.5
  • 17
    • 0036934964 scopus 로고    scopus 로고
    • FDA public health notification: Reducing radiation risk from computed tomography for paediatric and small adult patients
    • FDA public health notification: reducing radiation risk from computed tomography for paediatric and small adult patients. Pediatr Radiol 2002;32:314-16
    • (2002) Pediatr Radiol , vol.32 , pp. 314-316
  • 18
    • 0042845953 scopus 로고    scopus 로고
    • National conference on dose reduction in CT, with an emphasis on pediatric patients
    • Linton OW, Mettler Jr FA. National Council on Radiation Protection and Measurements National conference on dose reduction in CT, with an emphasis on paediatric patients. AJR Am J Roentgenol 2003;181:321-29 (Pubitemid 36909472)
    • (2003) American Journal of Roentgenology , vol.181 , Issue.2 , pp. 321-329
    • Linton, O.W.1    Mettler Jr., F.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.