메뉴 건너뛰기




Volumn , Issue , 2007, Pages 29-45

Implementing deconvolution analysis for perfusion CT

Author keywords

[No Author keywords available]

Indexed keywords


EID: 81555214634     PISSN: None     EISSN: None     Source Type: Book    
DOI: None     Document Type: Chapter
Times cited : (6)

References (15)
  • 2
    • 84890326874 scopus 로고
    • A technique for the numerical solution of certain integral equations of the first kind
    • Philips DL. A technique for the numerical solution of certain integral equations of the first kind. J Assoc Comp Math 1962; 9: 84-90
    • (1962) J Assoc Comp Math , vol.9 , pp. 84-90
    • Philips, D.L.1
  • 3
    • 0001300995 scopus 로고
    • Regularizations of uncorrectly posed problems
    • Tikhonov AN. Regularizations of uncorrectly posed problems. Soviet Math 1963; 4: 1624-9
    • (1963) Soviet Math , vol.4 , pp. 1624-1629
    • Tikhonov, A.N.1
  • 5
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis
    • Østergaard L, Weisskoff RM, Chesler DA, et al. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis. Magn Reson Med 1996; 36: 715-25
    • (1996) Magn Reson Med , vol.36 , pp. 715-725
    • Østergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3
  • 6
    • 0029909977 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part II: Experimental comparison and preliminary results
    • Østergaard L, Sorensen AG, Kwong KK, et al. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part II: Experimental comparison and preliminary results. Magn Reson Med 1996; 36: 726-36
    • (1996) Magn Reson Med , vol.36 , pp. 726-736
    • Østergaard, L.1    Sorensen, A.G.2    Kwong, K.K.3
  • 7
    • 0344305580 scopus 로고    scopus 로고
    • Quantification of bolus-tracking MRI: Improved characterization of the tissue residue function using Tikhonov regularization
    • Calamante F, Gadian DG, Connelly A. Quantification of bolus-tracking MRI: improved characterization of the tissue residue function using Tikhonov regularization. Magn Reson Med 2003; 50: 1237-47
    • (2003) Magn Reson Med , vol.50 , pp. 1237-1247
    • Calamante, F.1    Gadian, D.G.2    Connelly, A.3
  • 8
    • 0001570653 scopus 로고
    • Biased estimation for nonparametric identification of linear systems
    • Hunt BR. Biased estimation for nonparametric identification of linear systems. Math Biosci 1971; 10: 215-37
    • (1971) Math Biosci , vol.10 , pp. 215-237
    • Hunt, B.R.1
  • 10
    • 0000570697 scopus 로고
    • Analysis of discrete ill-posed problems by means of the L-curve
    • Hansen PC. Analysis of discrete ill-posed problems by means of the L-curve. SIAM Rev 1992; 34: 561-80
    • (1992) SIAM Rev , vol.34 , pp. 561-580
    • Hansen, P.C.1
  • 11
    • 0033812331 scopus 로고    scopus 로고
    • Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decomposition
    • Calamante F, Gadian DG, Connelly A. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med 2000; 44: 466-73
    • (2000) Magn Reson Med , vol.44 , pp. 466-473
    • Calamante, F.1    Gadian, D.G.2    Connelly, A.3
  • 12
    • 0141617505 scopus 로고    scopus 로고
    • Effects of tracer arrival time on flow estimates in MR perfusion-weighted imaging
    • Wu O, Østergaard L, Koroshetz WJ, et al. Effects of tracer arrival time on flow estimates in MR perfusion-weighted imaging. Magn Reson Med 2003; 50: 856-64
    • (2003) Magn Reson Med , vol.50 , pp. 856-864
    • Wu, O.1    Østergaard, L.2    Koroshetz, W.J.3
  • 13
    • 14644402442 scopus 로고    scopus 로고
    • Tracer delay correction of cerebral blood flow with dynamic susceptibility contrast-enhanced MRI
    • Ibaraki M, Shimosegawa E, Toyoshima H, et al. Tracer delay correction of cerebral blood flow with dynamic susceptibility contrast-enhanced MRI. J Cereb Blood Flow Metab 2005; 25: 378-90
    • (2005) J Cereb Blood Flow Metab , vol.25 , pp. 378-390
    • Ibaraki, M.1    Shimosegawa, E.2    Toyoshima, H.3
  • 14
    • 0037587219 scopus 로고    scopus 로고
    • Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix
    • Wu O, Østergaard L, Weisskoff RM, et al. Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix. Magn Reson Med 2003; 50: 164-74
    • (2003) Magn Reson Med , vol.50 , pp. 164-174
    • Wu, O.1    Østergaard, L.2    Weisskoff, R.M.3
  • 15
    • 1542346897 scopus 로고    scopus 로고
    • Removing the effect of SVD algorithmic artifacts present in quantitative MR perfusion studies
    • Smith MR, Lu H, Trochet S, Frayne R. Removing the effect of SVD algorithmic artifacts present in quantitative MR perfusion studies. Magn Reson Med 2004; 51: 631-4
    • (2004) Magn Reson Med , vol.51 , pp. 631-634
    • Smith, M.R.1    Lu, H.2    Trochet, S.3    Frayne, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.