메뉴 건너뛰기




Volumn 78, Issue 6, 2011, Pages 898-908

Acute and 16-month outcomes of a new stent: The first-in-man evaluation of the medtronic S9 (integrity) stent

Author keywords

continuous sinusoidal technology; integrity stent; very deliverable stent

Indexed keywords

AGED; ARTERIOGRAPHY; ARTICLE; BARE METAL STENT; CAUSE OF DEATH; CLINICAL ARTICLE; CONFORMABILITY; CONTROLLED STUDY; CORONARY ARTERY OBSTRUCTION; CORONARY ARTERY RECANALIZATION; DELIVERABILITY; DEVICE RECALL; DEVICE SAFETY; DRUG ELUTING STENT; FEMALE; FLEXIBILITY; FOLLOW UP; HEART MUSCLE ISCHEMIA; HUMAN; MALE; OUTCOME ASSESSMENT; PHYSICAL PARAMETERS; PROCESS OPTIMIZATION; QUALITY CONTROL; RADIAL ARTERY; THERAPY EFFECT; VALIDATION PROCESS;

EID: 81455154358     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.23267     Document Type: Article
Times cited : (9)

References (10)
  • 1
    • 0034757333 scopus 로고    scopus 로고
    • Role of stenting in coronary revascularization
    • Gershlick AH,. Role of stenting in coronary revascularization. Heart 2001; 86: 104-112.
    • (2001) Heart , vol.86 , pp. 104-112
    • Gershlick, A.H.1
  • 2
    • 0026507461 scopus 로고
    • Intracoronary stenting for acute and threatened closure complicating percutaneous transluminal coronary angioplasty
    • Roubin GS, Cannon AD, Agrawal SK, et al. Intracoronary stenting for acute and threatened closure complicating percutaneous transluminal coronary angioplasty. Circulation 1992; 85: 916-927.
    • (1992) Circulation , vol.85 , pp. 916-927
    • Roubin, G.S.1    Cannon, A.D.2    Agrawal, S.K.3
  • 7
    • 0032499021 scopus 로고    scopus 로고
    • Pathobiological responses to stenting
    • Edelman ER, Rogers C,. Pathobiological responses to stenting. Am J Cardiol 1998; 81: 4E-6E.
    • (1998) Am J Cardiol , vol.81
    • Edelman, E.R.1    Rogers, C.2
  • 8
    • 20444475661 scopus 로고    scopus 로고
    • Cardiovascular stent design and vessel stresses: A finite element analysis
    • DOI 10.1016/j.jbiomech.2004.07.022, PII S0021929004003756
    • Lally C, Dolan F, Prendergast PJ,. Cardiovascular stent design and vessel stresses: A finite element analysis. J Biomech 2005; 38: 1574-1581. (Pubitemid 40813479)
    • (2005) Journal of Biomechanics , vol.38 , Issue.8 , pp. 1574-1581
    • Lally, C.1    Dolan, F.2    Prendergast, P.J.3
  • 9
    • 74249102209 scopus 로고    scopus 로고
    • A novel simulation strategy for stent insertion and deployment in curved coronary bifurcations: Comparison of three drug-eluting stents
    • Mortier P, Holzapfel GA, Beule MD, et al. A novel simulation strategy for stent insertion and deployment in curved coronary bifurcations: Comparison of three drug-eluting stents. Anna Biomed Eng 2010; 38: 88-99.
    • (2010) Anna Biomed Eng , vol.38 , pp. 88-99
    • Mortier, P.1    Holzapfel, G.A.2    Beule, M.D.3
  • 10
    • 0343729980 scopus 로고    scopus 로고
    • Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events
    • DOI 10.1016/S0735-1097(00)00570-2, PII S0735109700005702
    • Gyongyosi M, Yang P, Khorsand A, Glogar D,. Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events. Australian Wiktor stent study group and European paragon stent investigators. J Am Coll Cardiol 2000; 35: 1580-1589. (Pubitemid 30307504)
    • (2000) Journal of the American College of Cardiology , vol.35 , Issue.6 , pp. 1580-1589
    • Gyongyosi, M.1    Yang, P.2    Khorsand, A.3    Glogar, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.