메뉴 건너뛰기




Volumn 58, Issue 11, 2011, Pages 2334-2343

Lesion generation through ribs using histotripsy therapy without aberration correction

Author keywords

[No Author keywords available]

Indexed keywords

ABERRATION CORRECTION; BUBBLE CLOUD; CAVITATION BUBBLE; CAVITATION INITIATION; COLLATERAL DAMAGE; FOCUSED TRANSDUCER; HIGH SPEED IMAGING; REPETITION FREQUENCY; SINGLE BUBBLES; THERAPEUTIC ULTRASOUND; TISSUE MIMICKING PHANTOM;

EID: 81355149464     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2011.2091     Document Type: Article
Times cited : (24)

References (27)
  • 1
    • 11144354898 scopus 로고    scopus 로고
    • Extracorporeal high intensity focused ultrasound ablation in the treatment of 1038 patients with solid carcinomas in China: An overview
    • DOI 10.1016/j.ultsonch.2004.01.011, PII S1350417704000136
    • F. Wu, Z. B. Wang, W. Z. Chen, W. Wang, Y. Gui, M. Zhang, G. Zheng, Y. Zhou, G. Xu, M. Li, C. Zhang, H. Ye, and R. Feng, "Extracorporeal high intensity focused ultrasound ablation in the treatment of 1038 patients with solid carcinomas in China: An overview," Ultrason. Sonochem., vol. 11, pp. 149-154, May 2004. (Pubitemid 38479821)
    • (2004) Ultrasonics Sonochemistry , vol.11 , Issue.3-4 , pp. 149-154
    • Wu, F.1    Wang, Z.-B.2    Chen, W.-Z.3    Wang, W.4    Gui, Y.5    Zhang, M.6    Zheng, G.7    Zhou, Y.8    Xu, G.9    Li, M.10    Zhang, C.11    Ye, H.12    Feng, R.13
  • 3
    • 79955463020 scopus 로고    scopus 로고
    • High-intensity focused ultrasound ablation in hepatic and pancreatic cancer: Complications
    • S. E. Jung, S. H. Cho, J. H. Jang, and J. Y. Han, "High-intensity focused ultrasound ablation in hepatic and pancreatic cancer: Complications," Abdom. Imaging, vol. 36, no. 2, pp. 185-195, 2010.
    • (2010) Abdom. Imaging , vol.36 , Issue.2 , pp. 185-195
    • Jung, S.E.1    Cho, S.H.2    Jang, J.H.3    Han, J.Y.4
  • 4
    • 34250754815 scopus 로고    scopus 로고
    • Complications of high intensity focused ultrasound in patients with recurrent and metastatic abdominal tumors
    • J. J. Li, G. L. Xu, M. F. Gu, G. Y. Luo, Z. Rong, P. H. Wu, and J. C. Xia, "Complications of high intensity focused ultrasound in patients with recurrent and metastatic abdominal tumors," World J. Gastroenterol., vol. 13, pp. 2747-2751, May 21, 2007. (Pubitemid 46958732)
    • (2007) World Journal of Gastroenterology , vol.13 , Issue.19 , pp. 2747-2751
    • Li, J.-J.1    Xu, G.-L.2    Gu, M.-F.3    Luo, G.-Y.4    Rong, Z.5    Wu, P.-H.6    Xia, J.-C.7
  • 6
    • 33750841780 scopus 로고    scopus 로고
    • The use of a segmented transducer for rib sparing in HIFU treatments
    • DOI 10.1016/j.ultrasmedbio.2006.06.005, PII S0301562906016772
    • J. Civale, R. Clarke, I. Rivens, and G. ter Haar, "The use of a segmented transducer for rib sparing in HIFU treatments," Ultrasound Med. Biol., vol. 32, pp. 1753-1761, Nov. 2006. (Pubitemid 44716582)
    • (2006) Ultrasound in Medicine and Biology , vol.32 , Issue.11 , pp. 1753-1761
    • Civale, J.1    Clarke, R.2    Rivens, I.3    Ter Haar, G.4
  • 7
    • 45749090481 scopus 로고    scopus 로고
    • Transcostal high-intensity-focused ultrasound: Ex vivo adaptive focusing feasibility study
    • DOI 10.1088/0031-9155/53/11/012, PII S0031915508725910
    • J. F. Aubry, M. Pernot, F. Marquet, M. Tanter, and M. Fink, "Transcostal high-intensity-focused ultrasound: Ex vivo adaptive focusing feasibility study," Phys. Med. Biol., vol. 53, pp. 2937-2951, Jun. 7, 2008. (Pubitemid 351868615)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.11 , pp. 2937-2951
    • Aubry, J.-F.1    Pernot, M.2    Marquet, F.3    Tanter, M.4    Fink, M.5
  • 8
    • 76649127392 scopus 로고    scopus 로고
    • Adaptive transthoracic refocusing of dual-mode ultrasound arrays
    • Jan.
    • J. R. Ballard, A. J. Casper, Y. Wan, and E. S. Ebbini, "Adaptive transthoracic refocusing of dual-mode ultrasound arrays," IEEE Trans. Biomed. Eng., vol. 57, pp. 93-102, Jan. 2010.
    • (2010) IEEE Trans. Biomed. Eng. , vol.57 , pp. 93-102
    • Ballard, J.R.1    Casper, A.J.2    Wan, Y.3    Ebbini, E.S.4
  • 9
    • 68149160249 scopus 로고    scopus 로고
    • Ultrasonic focusing through the ribs using the DORT method
    • Aug.
    • E. Cochard, C. Prada, J. F. Aubry, and M. Fink, "Ultrasonic focusing through the ribs using the DORT method," Med. Phys., vol. 36, pp. 3495-3503, Aug. 2009.
    • (2009) Med. Phys. , vol.36 , pp. 3495-3503
    • Cochard, E.1    Prada, C.2    Aubry, J.F.3    Fink, M.4
  • 10
    • 75749132486 scopus 로고    scopus 로고
    • Focal beam distortion and treatment planning for transrib focused ultrasound thermal therapy: A feasibility study using a two-dimensional ultrasound phased array
    • Feb.
    • H. L. Liu, C. L. Hsu, S. M. Huang, and Y. W. Hsi, "Focal beam distortion and treatment planning for transrib focused ultrasound thermal therapy: A feasibility study using a two-dimensional ultrasound phased array," Med. Phys., vol. 37, pp. 848-860, Feb. 2010.
    • (2010) Med. Phys. , vol.37 , pp. 848-860
    • Liu, H.L.1    Hsu, C.L.2    Huang, S.M.3    Hsi, Y.W.4
  • 11
    • 77953495687 scopus 로고    scopus 로고
    • A method for MRI guidance of intercostal high intensity focused ultrasound ablation in the liver
    • Jun.
    • B. Quesson, M. Merle, M. O. Kohler, C. Mougenot, S. Roujol, B. D. de Senneville, and C. T. Moonen, "A method for MRI guidance of intercostal high intensity focused ultrasound ablation in the liver," Med. Phys., vol. 37, pp. 2533-2540, Jun. 2010.
    • (2010) Med. Phys. , vol.37 , pp. 2533-2540
    • Quesson, B.1    Merle, M.2    Kohler, M.O.3    Mougenot, C.4    Roujol, S.5    De Senneville, B.D.6    Moonen, C.T.7
  • 12
    • 77953212956 scopus 로고    scopus 로고
    • Focusing of high-intensity ultrasound through the rib cage using a therapeutic random phased array
    • Jun.
    • S. Bobkova, L. Gavrilov, V. Khokhlova, A. Shaw, and J. Hand, "Focusing of high-intensity ultrasound through the rib cage using a therapeutic random phased array," Ultrasound Med. Biol., vol. 36, pp. 888-906, Jun. 2010.
    • (2010) Ultrasound Med. Biol. , vol.36 , pp. 888-906
    • Bobkova, S.1    Gavrilov, L.2    Khokhlova, V.3    Shaw, A.4    Hand, J.5
  • 13
    • 29144507666 scopus 로고    scopus 로고
    • Pulsed cavitational ultrasound therapy for controlled tissue homogenization
    • DOI 10.1016/j.ultrasmedbio.2005.09.005, PII S0301562905003741
    • J. E. Parsons, C. A. Cain, G. D. Abrams, and J. B. Fowlkes, "Pulsed cavitational ultrasound therapy for controlled tissue homogenization," Ultrasound Med. Biol., vol. 32, pp. 115-129, Jan. 2006. (Pubitemid 41814867)
    • (2006) Ultrasound in Medicine and Biology , vol.32 , Issue.1 , pp. 115-129
    • Parsons, J.E.1    Cain, C.A.2    Abrams, G.D.3    Fowlkes, J.B.4
  • 14
    • 35349002304 scopus 로고    scopus 로고
    • Histotripsy of rabbit renal tissue in vivo: Temporal histologic trends
    • Oct.
    • T. L. Hall, K. Kieran, K. Ives, J. B. Fowlkes, C. A. Cain, and W. W. Roberts, "Histotripsy of rabbit renal tissue in vivo: Temporal histologic trends," J. Endourol., vol. 21, pp. 1159-1166, Oct. 2007.
    • (2007) J. Endourol. , vol.21 , pp. 1159-1166
    • Hall, T.L.1    Kieran, K.2    Ives, K.3    Fowlkes, J.B.4    Cain, C.A.5    Roberts, W.W.6
  • 16
    • 34447103095 scopus 로고    scopus 로고
    • Refining histotripsy: Defining the parameter space for the creation of nonthermal lesions with high intensity, pulsed focused ultrasound of the in vitro kidney
    • DOI 10.1016/j.juro.2007.03.093, PII S0022534707007410
    • K. Kieran, T. L. Hall, J. E. Parsons, J. S. Wolf Jr., J. B. Fowlkes, C. A. Cain, and W. W. Roberts, "Refining histotripsy: Defining the parameter space for the creation of nonthermal lesions with high intensity, pulsed focused ultrasound of the in vitro kidney," J. Urol., vol. 178, pp. 672-676, Aug. 2007. (Pubitemid 47030474)
    • (2007) Journal of Urology , vol.178 , Issue.2 , pp. 672-676
    • Kieran, K.1    Hall, T.L.2    Parsons, J.E.3    Wolf Jr., J.S.4    Fowlkes, J.B.5    Cain, C.A.6    Roberts, W.W.7
  • 17
    • 28844454163 scopus 로고    scopus 로고
    • Investigation of intensity thresholds for ultrasound tissue erosion
    • DOI 10.1016/j.ultrasmedbio.2005.07.016, PII S0301562905003066
    • Z. Xu, J. B. Fowlkes, A. Ludomirsky, and C. A. Cain, "Investigation of intensity thresholds for ultrasound tissue erosion," Ultrasound Med. Biol., vol. 31, pp. 1673-1682, Dec. 2005. (Pubitemid 41774685)
    • (2005) Ultrasound in Medicine and Biology , vol.31 , Issue.12 , pp. 1673-1682
    • Xu, Z.1    Fowlkes, J.B.2    Ludomirsky, A.3    Cain, C.A.4
  • 18
    • 12344327720 scopus 로고    scopus 로고
    • Controlled ultrasound tissue erosion: The role of dynamic interaction between insonation and microbubble activity
    • DOI 10.1121/1.1828551
    • Z. Xu, J. B. Fowlkes, E. D. Rothman, A. M. Levin, and C. A. Cain, "Controlled ultrasound tissue erosion: The role of dynamic interaction between insonation and microbubble activity," J. Acoust. Soc. Am., vol. 117, pp. 424-435, Jan. 2005. (Pubitemid 40130169)
    • (2005) Journal of the Acoustical Society of America , vol.117 , Issue.1 , pp. 424-435
    • Xu, Z.1    Fowlkes, J.B.2    Rothman, E.D.3    Levin, A.M.4    Cain, C.A.5
  • 20
    • 33644661136 scopus 로고    scopus 로고
    • Cost-effective assembly of a basic fiber-optic hydrophone for measurement of high-amplitude therapeutic ultrasound fields
    • DOI 10.1121/1.2166708
    • J. E. Parsons, C. A. Cain, and J. B. Fowlkes, "Cost-effective assembly of a basic fiber-optic hydrophone for measurement of highamplitude therapeutic ultrasound fields," J. Acoust. Soc. Am., vol. 119, pp. 1432-1440, Mar. 2006. (Pubitemid 43326012)
    • (2006) Journal of the Acoustical Society of America , vol.119 , Issue.3 , pp. 1432-1440
    • Parsons, J.E.1    Cain, C.A.2    Fowlkes, J.B.3
  • 21
    • 78449313547 scopus 로고    scopus 로고
    • A tissue phantom for visualization and measurement of ultrasound-induced cavitation damage
    • Dec.
    • A. D. Maxwell, T. Y. Wang, L. Yuan, A. P. Duryea, Z. Xu, and C. A. Cain, "A tissue phantom for visualization and measurement of ultrasound-induced cavitation damage," Ultrasound Med. Biol., vol. 36, pp. 2132-2143, Dec. 2010.
    • (2010) Ultrasound Med. Biol. , vol.36 , pp. 2132-2143
    • Maxwell, A.D.1    Wang, T.Y.2    Yuan, L.3    Duryea, A.P.4    Xu, Z.5    Cain, C.A.6
  • 23
    • 78049352251 scopus 로고    scopus 로고
    • Focus splitting associated with propagation of focused ultrasound through the rib cage
    • V. Khokhlova, S. Bobkova, and L. Gavrilov, "Focus splitting associated with propagation of focused ultrasound through the rib cage," Acoust. Phys., vol. 56, no. 5, pp. 665-674, 2010.
    • (2010) Acoust. Phys. , vol.56 , Issue.5 , pp. 665-674
    • Khokhlova, V.1    Bobkova, S.2    Gavrilov, L.3
  • 24
    • 0028202007 scopus 로고
    • Phase aberration correction and motion compensation for ultrasonic hyperthermia phased arrays: Experimental results
    • W. Hong, E. S. Ebbini, M. O'Donnell, and C. A. Cain, "Phase aberration correction and motion compensation for ultrasonic hyperthermia phased arrays: Experimental results," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 41, no. 1, pp. 34-43, 1994.
    • (1994) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.41 , Issue.1 , pp. 34-43
    • Hong, W.1    Ebbini, E.S.2    O'Donnell, M.3    Cain, C.A.4
  • 25
    • 0024023693 scopus 로고
    • Cavitation threshold measurements for microsecond length pulses of ultrasound
    • Jun.
    • J. B. Fowlkes and L. A. Crum, "Cavitation threshold measurements for microsecond length pulses of ultrasound," J. Acoust. Soc. Am., vol. 83, pp. 2190-2201, Jun. 1988.
    • (1988) J. Acoust. Soc. Am. , vol.83 , pp. 2190-2201
    • Fowlkes, J.B.1    Crum, L.A.2
  • 26
    • 0025258575 scopus 로고
    • Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment
    • Nov.
    • C. K. Holland and R. E. Apfel, "Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment," J. Acoust. Soc. Am., vol. 88, pp. 2059-2069, Nov. 1990.
    • (1990) J. Acoust. Soc. Am. , vol.88 , pp. 2059-2069
    • Holland, C.K.1    Apfel, R.E.2
  • 27
    • 0028906017 scopus 로고
    • The cavitation threshold of human tissue exposed to 0.2-MHz pulsed ultrasound: Preliminary measurements based on a study of clinical lithotripsy
    • A. J. Coleman, T. Kodama, M. J. Choi, T. Adams, and J. E. Saunders, "The cavitation threshold of human tissue exposed to 0.2-MHz pulsed ultrasound: Preliminary measurements based on a study of clinical lithotripsy," Ultrasound Med. Biol., vol. 21, no. 3, pp. 405-417, 1995.
    • (1995) Ultrasound Med. Biol. , vol.21 , Issue.3 , pp. 405-417
    • Coleman, A.J.1    Kodama, T.2    Choi, M.J.3    Adams, T.4    Saunders, J.E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.