메뉴 건너뛰기




Volumn 2, Issue 5, 2008, Pages 822-827

Assessment of glycated Hemoglobin using AlCNow+™ point-of-care device as compared to central laboratory testing

Author keywords

Diabetes; Hemoglobin Alc; Point of care

Indexed keywords


EID: 81255205031     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229680800200512     Document Type: Article
Times cited : (19)

References (11)
  • 1
    • 84887233667 scopus 로고    scopus 로고
    • accessed 2008 Mar. 12
    • American Diabetes Association [accessed 2008 Mar. 12]. Available from: www.diabetes.org.
  • 4
    • 0032845440 scopus 로고    scopus 로고
    • Diabetes in urban African-Americans. XVII. Availability of rapid HbAlc measurements enhances clinical decision making
    • Thaler LM, Ziemer DC, Gallina DL, Cook CB, Dunbar VG, Phillips LS, El-Kebbi IM. Diabetes in urban African-Americans. XVII. Availability of rapid HbAlc measurements enhances clinical decision making. Diabetes Care. 1999;22(9):1415-21.
    • (1999) Diabetes Care , vol.22 , Issue.9 , pp. 1415-1421
    • Thaler, L.M.1    Ziemer, D.C.2    Gallina, D.L.3    Cook, C.B.4    Dunbar, V.G.5    Phillips, L.S.6    El-Kebbi, I.M.7
  • 5
    • 0008337925 scopus 로고    scopus 로고
    • Effect of immediate feedback of HbAlc on patient glycemic control and physicians' treatment decisions [abstract]
    • Marrero DG, Kraft S, Fineberg N. Effect of immediate feedback of HbAlc on patient glycemic control and physicians' treatment decisions [abstract]. Diabetes. 1996;45:7A.
    • (1996) Diabetes , vol.45
    • Marrero, D.G.1    Kraft, S.2    Fineberg, N.3
  • 6
    • 0032589807 scopus 로고    scopus 로고
    • Immediate feedback of HbAlc levels improves glycemic control in type 1 and insulin-treated type 2 diabetic patients
    • Cagliero E, Levina E, Nathan DM. Immediate feedback of HbAlc levels improves glycemic control in type 1 and insulin-treated type 2 diabetic patients. Diabetes Care. 1999;22(11):1785-88.
    • (1999) Diabetes Care , vol.22 , Issue.11 , pp. 1785-1788
    • Cagliero, E.1    Levina, E.2    Nathan, D.M.3
  • 7
    • 18844430593 scopus 로고    scopus 로고
    • Comparison of point-of-care HbAlc test versus standardized laboratory
    • Sicard DA, Taylor JR. Comparison of point-of-care HbAlc test versus standardized laboratory. Ann Pharmacother. 2005;39(6):1024-28.
    • (2005) Ann Pharmacother , vol.39 , Issue.6 , pp. 1024-1028
    • Sicard, D.A.1    Taylor, J.R.2
  • 9
    • 31144463164 scopus 로고    scopus 로고
    • Glycated hemoglobin assessment in clinical practice: Comparison of the AlcNow point-of-care device with central laboratory testing (GOAL A1C Study)
    • GOAL A1C Study Team
    • Kennedy L, Herman WH; GOAL A1C Study Team. Glycated hemoglobin assessment in clinical practice: comparison of the AlcNow point-of-care device with central laboratory testing (GOAL A1C Study). Diabetes Technol Ther. 2005;7(6):907-12.
    • (2005) Diabetes Technol Ther. , vol.7 , Issue.6 , pp. 907-912
    • Kennedy, L.1    Herman, W.H.2
  • 10
    • 84887261206 scopus 로고    scopus 로고
    • Metrika Incorporated, Sunnyvale, CA: Metrika
    • Metrika Incorporated. AlCNow+ package insert. Sunnyvale, CA: Metrika; 2006.
    • (2006) AlCNow+ Package Insert
  • 11
    • 84887226198 scopus 로고    scopus 로고
    • accessed 2008 Mar. 7
    • Metrika Incorporated [accessed 2008 Mar. 7]. Available from: www.metrika.com.
    • Metrika Incorporated


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.