메뉴 건너뛰기




Volumn 160, Issue 1, 2011, Pages 637-643

Selective determination of urea using urease immobilized on ZnO nanowires

Author keywords

Electrochemical nanodevices; Urea determination; Urease enzyme; ZnO nanowire arrays

Indexed keywords

AQUEOUS CHEMICAL GROWTH; ASCORBIC ACIDS; CONCENTRATION RANGES; ELECTROCHEMICAL RESPONSE; FAST RESPONSE TIME; GOLD-COATED; INTERFERENTS; LINEAR SENSITIVITY; LOW TEMPERATURES; NANO-DEVICES; NANOWIRE ARRAYS; PLASTIC SUBSTRATES; REPRODUCIBILITIES; SELECTIVE DETERMINATION; UREASE ENZYME; URIC ACIDS; WELL-ALIGNED; ZNO; ZNO NANOWIRES; ZNO-NANOWIRE ARRAYS;

EID: 81155152251     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.08.041     Document Type: Article
Times cited : (85)

References (28)
  • 4
    • 0141956404 scopus 로고    scopus 로고
    • A novel urea sensitive biosensor with extended dynamic range based on recombinant urease and ISFETs
    • A.P. Soldatkin, J. Montoriol, W. Sant, C. Martelet, and N.J. Renault A novel urea sensitive biosensor with extended dynamic range based on recombinant urease and ISFETs Biosens. Bioelectron. 19 2003 131 135
    • (2003) Biosens. Bioelectron. , vol.19 , pp. 131-135
    • Soldatkin, A.P.1    Montoriol, J.2    Sant, W.3    Martelet, C.4    Renault, N.J.5
  • 5
    • 48649086664 scopus 로고    scopus 로고
    • Development of potentiometric urea biosensor based on urease immobilized in PVA-PAA composite matrix for estimation of blood urea nitrogen (BUN)
    • S.K. Jha, A. Topkar, and S.F. D'Souza Development of potentiometric urea biosensor based on urease immobilized in PVA-PAA composite matrix for estimation of blood urea nitrogen (BUN) J. Biochem. Biophys. Methods 70 2008 1145 1150
    • (2008) J. Biochem. Biophys. Methods , vol.70 , pp. 1145-1150
    • Jha, S.K.1    Topkar, A.2    D'Souza, S.F.3
  • 6
    • 11744312829 scopus 로고
    • Determination of urea in blood and urine with diacetyl monoxime
    • H.L. Rosenthal Determination of urea in blood and urine with diacetyl monoxime Anal. Chem. 27 1955 1980 1982
    • (1955) Anal. Chem. , vol.27 , pp. 1980-1982
    • Rosenthal, H.L.1
  • 7
    • 0028670525 scopus 로고
    • Urea and lactate determined in 1-μL whole blood with a miniaturized thermal biosensor
    • B. Xie, U. Harborn, M. Mecklenburg, and B. Danielsson Urea and lactate determined in 1-μL whole blood with a miniaturized thermal biosensor Clin. Chem. 40 1994 2282 2287
    • (1994) Clin. Chem. , vol.40 , pp. 2282-2287
    • Xie, B.1    Harborn, U.2    Mecklenburg, M.3    Danielsson, B.4
  • 8
    • 14744278807 scopus 로고    scopus 로고
    • Electrochemical immunosensors for the simultaneous detection of two tumor markers
    • M.S. Wilson Electrochemical immunosensors for the simultaneous detection of two tumor markers Anal. Chem. 77 2005 1496 1502
    • (2005) Anal. Chem. , vol.77 , pp. 1496-1502
    • Wilson, M.S.1
  • 9
    • 12444330291 scopus 로고    scopus 로고
    • Biosensors in clinical chemistry
    • P. D'Orazio Biosensors in clinical chemistry Clin. Chim. Acta 334 2003 41 69
    • (2003) Clin. Chim. Acta , vol.334 , pp. 41-69
    • D'Orazio, P.1
  • 12
    • 70749117080 scopus 로고    scopus 로고
    • Glucose detection with a commercial MOSFET using a ZnO nanowires extended gate
    • S.M. Usman Ali, O. Nur, M. Willander, and B. Danielsson Glucose detection with a commercial MOSFET using a ZnO nanowires extended gate IEEE Trans. Nanotechnol. 8 2009 678 683
    • (2009) IEEE Trans. Nanotechnol. , vol.8 , pp. 678-683
    • Usman Ali, S.M.1    Nur, O.2    Willander, M.3    Danielsson, B.4
  • 13
    • 77949291902 scopus 로고    scopus 로고
    • A fast and sensitive potentiometric glucose microsensor based on glucose oxidase coated ZnO nanowires grown on a thin silver wire
    • S.M. Usman Ali, O. Nur, M. Willander, and B. Danielsson A fast and sensitive potentiometric glucose microsensor based on glucose oxidase coated ZnO nanowires grown on a thin silver wire Sens. Actuators B: Chem. 145 2010 869 874
    • (2010) Sens. Actuators B: Chem. , vol.145 , pp. 869-874
    • Usman Ali, S.M.1    Nur, O.2    Willander, M.3    Danielsson, B.4
  • 15
    • 46649120523 scopus 로고    scopus 로고
    • Sol-gel derived nanostructured cerium oxide film for glucose sensor
    • A.A. Ansari, P.R. Solanki, and B.D. Malhotra Sol-gel derived nanostructured cerium oxide film for glucose sensor Appl. Phys. Lett. 92 2008 263901 263903
    • (2008) Appl. Phys. Lett. , vol.92 , pp. 263901-263903
    • Ansari, A.A.1    Solanki, P.R.2    Malhotra, B.D.3
  • 16
    • 0042890314 scopus 로고    scopus 로고
    • Direct electrochemistry and nitric oxide interaction of heme proteins adsorbed on nanocrystalline tin oxide electrodes
    • E. Topoglidis, Y. Astuti, F. Duriaux, M. Gratzel, and J.R. Durrant Direct electrochemistry and nitric oxide interaction of heme proteins adsorbed on nanocrystalline tin oxide electrodes Langmuir 19 2003 6894 6900
    • (2003) Langmuir , vol.19 , pp. 6894-6900
    • Topoglidis, E.1    Astuti, Y.2    Duriaux, F.3    Gratzel, M.4    Durrant, J.R.5
  • 17
    • 0037099226 scopus 로고    scopus 로고
    • Preparation of porous titania sol-gel matrix for immobilization of horseradish peroxidase by a vapor deposition method
    • J. Yu, and H. Ju Preparation of porous titania sol-gel matrix for immobilization of horseradish peroxidase by a vapor deposition method Anal. Chem. 74 2002 3579 3583
    • (2002) Anal. Chem. , vol.74 , pp. 3579-3583
    • Yu, J.1    Ju, H.2
  • 20
    • 22144474439 scopus 로고    scopus 로고
    • A mediator-free tyrosinase biosensor based on ZnO sol-gel matrix
    • Z. Liu, Y. Liu, H. Yang, Y. Yang, G. Shen, and R. Yu A mediator-free tyrosinase biosensor based on ZnO sol-gel matrix Electroanalysis 17 2005 1065 1070
    • (2005) Electroanalysis , vol.17 , pp. 1065-1070
    • Liu, Z.1    Liu, Y.2    Yang, H.3    Yang, Y.4    Shen, G.5    Yu, R.6
  • 21
    • 79951516501 scopus 로고    scopus 로고
    • Fabrication and comparative optical characterization of n-ZnO nanostructures (nanowalls, nanorods, nanoflowers and nanotubes)/p-GaN white light emitting diodes
    • N.H. Alvi, S.M. Usman Ali, S. Hussain, O. Nur, and M. Willander Fabrication and comparative optical characterization of n-ZnO nanostructures (nanowalls, nanorods, nanoflowers and nanotubes)/p-GaN white light emitting diodes Scripta Mater. 64 2011 697 700
    • (2011) Scripta Mater. , vol.64 , pp. 697-700
    • Alvi, N.H.1    Usman Ali, S.M.2    Hussain, S.3    Nur, O.4    Willander, M.5
  • 22
    • 16244397409 scopus 로고    scopus 로고
    • Controllable growth of ZnO nanostructures by citric acid assisted hydrothermal process
    • 1696
    • H. Zhang, D. Yang, S. Li, X. Ma, Y. Ji, J. Xu, and D. Qu Controllable growth of ZnO nanostructures by citric acid assisted hydrothermal process Mater. Lett. 59 2005 1700 1696
    • (2005) Mater. Lett. , vol.59 , pp. 1700
    • Zhang, H.1    Yang, D.2    Li, S.3    Ma, X.4    Ji, Y.5    Xu, J.6    Qu, D.7
  • 26
    • 16644398717 scopus 로고    scopus 로고
    • Selective and sensitive determination of uric acid at DNA-modified graphite powder microelectrodes
    • J.W. Luo, M. Zhang, and D.W. Pang Selective and sensitive determination of uric acid at DNA-modified graphite powder microelectrodes Sens. Actuators B: Chem. 106 2005 358 362
    • (2005) Sens. Actuators B: Chem. , vol.106 , pp. 358-362
    • Luo, J.W.1    Zhang, M.2    Pang, D.W.3
  • 27


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.