메뉴 건너뛰기




Volumn 46, Issue 12, 2011, Pages 1209-1214

Evaluation of impulse oscillometry during bronchial challenge testing in children

Author keywords

airway resistance; asthma; bronchial provocation tests; respiratory function tests

Indexed keywords

METHACHOLINE;

EID: 81155146371     PISSN: 87556863     EISSN: 10990496     Source Type: Journal    
DOI: 10.1002/ppul.21492     Document Type: Article
Times cited : (29)

References (25)
  • 1
    • 0003206498 scopus 로고
    • Guidelines for bronchial inhalation challenges with pharmacologic and antigenic agents
    • Subcommittee on Bronchial Inhalation Challenges.
    • Subcommittee on Bronchial Inhalation Challenges. Guidelines for bronchial inhalation challenges with pharmacologic and antigenic agents. ATS News 1980; 11-19.
    • (1980) ATS News , pp. 11-19
  • 3
    • 0025073414 scopus 로고
    • Correspondence between forced oscillation and body plethysmography during bronchoprovocation with carbachol in children
    • Buhr W, Jorres R, Berdel D, Landser FJ,. Correspondence between forced oscillation and body plethysmography during bronchoprovocation with carbachol in children. Pediatr Pulmonol 1990; 8: 280-288.
    • (1990) Pediatr Pulmonol , vol.8 , pp. 280-288
    • Buhr, W.1    Jorres, R.2    Berdel, D.3    Landser, F.J.4
  • 4
    • 0023028809 scopus 로고
    • Comparison of forced oscillometry and forced expirations for measuring dose-related responses to inhaled methacholine in asthmatic children
    • Duiverman EJ, Neijens HJ, Van der Snee-van Smaalen M, Kerrebijn KF,. Comparison of forced oscillometry and forced expirations for measuring dose-related responses to inhaled methacholine in asthmatic children. Bull Eur Physiopathol Respir 1986; 22: 433-436. (Pubitemid 17173904)
    • (1986) Clinical Respiratory Physiology , vol.22 , Issue.5 , pp. 433-436
    • Duiverman, E.J.1    Neijens, H.J.2    Van Der Snee-Van Smaalen, M.3    Kerrebijn, K.F.4
  • 5
    • 0034820690 scopus 로고    scopus 로고
    • Evaluation of impulse oscillation system: Comparison with forced oscillation technique and body plethysmography
    • DOI 10.1183/09031936.01.00046401
    • Hellinckx J, Cauberghs M, De Boeck K, Demedts M,. Evaluation of impulse oscillation system: comparison with forced oscillation technique and body plethysmography. Eur Respir J 2001; 18: 564-570. (Pubitemid 32895644)
    • (2001) European Respiratory Journal , vol.18 , Issue.3 , pp. 564-570
    • Hellinckx, J.1    Cauberghs, M.2    De Boeck, K.3    Demedts, M.4
  • 7
    • 0346121617 scopus 로고    scopus 로고
    • The forced oscillation technique in clinical practice: Methodology, recommendations and future developments
    • Oostveen E, MacLeod D, Lorino H, Farré R, Hantos Z, Desager K, Marchal F,. The forced oscillation technique in clinical practice: methodology, recommendations and future developments. ERS Task Force on Respiratory Impedance Measurements. Eur Respir J 2003; 22: 1026-1041. (Pubitemid 37540659)
    • (2003) European Respiratory Journal , vol.22 , Issue.6 , pp. 1026-1041
    • Oostveen, E.1    MacLeod, D.2    Lorino, H.3    Farre, R.4    Hantos, Z.5    Desager, K.6    Marchal, F.7
  • 9
    • 0028811667 scopus 로고
    • Lung function measurement in awake young children
    • Bisgaard H, Klug B,. Lung function measurement in awake young children. Eur Respir J 1995; 8: 2067-2075.
    • (1995) Eur Respir J , vol.8 , pp. 2067-2075
    • Bisgaard, H.1    Klug, B.2
  • 10
    • 0029975553 scopus 로고    scopus 로고
    • Measurement of lung function in awake 2-4-year-old asthmatic children during methacholine challenge and acute asthma: A comparison of the impulse oscillation technique, the interrupter technique, and transcutaneous measurement of oxygen versus whole-body plethysmography
    • Klug B, Bisgaard H,. Measurement of lung function in awake 2-4-year-old asthmatic children during methacholine challenge and acute asthma: a comparison of the impulse oscillation technique, the interrupter technique, and transcutaneous measurement of oxygen versus whole-body plethysmography. Pediatr Pulmonol 1996; 21: 290-300.
    • (1996) Pediatr Pulmonol , vol.21 , pp. 290-300
    • Klug, B.1    Bisgaard, H.2
  • 11
    • 0029783331 scopus 로고    scopus 로고
    • Respiratory system reactance as an indicator of the intrathoracic airway response to methacholine in children
    • DOI 10.1002/(SICI)1099-0496(199607)22:1<7::AID-PPUL2>3.0.CO;2-P
    • Bouaziz N, Beyaert C, Gauthier R, Monin P, Peslin R, Marchal F,. Respiratory system reactance as an indicator of the intrathoracic airway response to methacholine in children. Pediatr Pulmonol 1996; 22: 7-13. (Pubitemid 26269736)
    • (1996) Pediatric Pulmonology , vol.22 , Issue.1 , pp. 7-13
    • Bouaziz, N.1    Beyaert, C.2    Gauthier, R.3    Monin, P.4    Peslin, R.5    Marchal, F.6
  • 12
    • 36349024706 scopus 로고    scopus 로고
    • Methacholine-induced asthma symptoms correlate with impulse oscillometry but not spirometry
    • DOI 10.1016/j.rmed.2007.08.007, PII S0954611107003617
    • Mansur AH, Manney S, Ayres JG,. Methacholine-induced asthma symptoms correlate with impulse oscillometry but not spirometry. Respir Med 2008; 102: 42-49. (Pubitemid 350151829)
    • (2008) Respiratory Medicine , vol.102 , Issue.1 , pp. 42-49
    • Mansur, A.H.1    Manney, S.2    Ayres, J.G.3
  • 13
    • 0020576693 scopus 로고
    • Analysis of time course and magnitude of lung inflation effects on airway tone: Relation to airway reactivity
    • Parham WM, Shepard RH, Norman PS, Fish JE,. Analysis of time course and magnitude of lung inflation effects on airway tone: relation to airway reactivity. Am Rev Respir Dis 1983; 128: 240-245. (Pubitemid 13037030)
    • (1983) American Review of Respiratory Disease , vol.128 , Issue.2 , pp. 240-245
    • Parham, W.M.1    Shepard, R.H.2    Norman, P.S.3    Fish, J.E.4
  • 14
    • 0021806363 scopus 로고
    • Laryngeal constriction in normal humans during experimentally induced bronchoconstriction
    • England SJ, Ho V, Zamel N,. Laryngeal constriction in normal humans during experimentally induced bronchoconstriction. J Appl Physiol 1985; 58: 352-356. (Pubitemid 15057742)
    • (1985) Journal of Applied Physiology , vol.58 , Issue.2 , pp. 352-356
    • England, S.J.1    Ho, V.2    Zamel, N.3
  • 16
    • 0027324961 scopus 로고
    • Responsiveness of and interactions between airways and tissue in guinea pigs during induced constriction
    • Nagase T, Ito T, Yanai M, Martin JG, Ludwig MS,. Responsiveness of and interactions between airways and tissue in guinea pigs during induced constriction. J Appl Physiol 1993; 74: 2848-2854. (Pubitemid 23201314)
    • (1993) Journal of Applied Physiology , vol.74 , Issue.6 , pp. 2848-2854
    • Nagase, T.1    Ito, T.2    Yanai, M.3    Martin, J.G.4    Ludwig, M.S.5
  • 17
    • 0034084755 scopus 로고    scopus 로고
    • Respiratory and upper airways impedance responses to methacholine inhalation in spontaneously breathing cats
    • DOI 10.1034/j.1399-3003.2000.01505.x
    • Loos N, Peslin R, Marchal F,. Respiratory and upper airways impedance responses to methacholine inhalation in spontaneously breathing cats. Eur Respir J 2000; 15: 1001-1008. (Pubitemid 30399267)
    • (2000) European Respiratory Journal , vol.15 , Issue.6 , pp. 1001-1008
    • Loos, N.1    Peslin, R.2    Marchal, F.3
  • 18
    • 0028927833 scopus 로고
    • The measurement of methacholine responsiveness in 5 year old children: Three methods compared
    • Wilson NM, Bridge P, Phagoo SB, Silverman M,. The measurement of methacholine responsiveness in 5 year old children: three methods compared. Eur Respir J 1995; 8: 364-370.
    • (1995) Eur Respir J , vol.8 , pp. 364-370
    • Wilson, N.M.1    Bridge, P.2    Phagoo, S.B.3    Silverman, M.4
  • 19
    • 0022337588 scopus 로고
    • Respiratory impedance measured with head generator to minimize upper airway shunt
    • Peslin R, Duvivier C, Didelon J, Gallina C,. Respiratory impedance measured with head generator to minimize upper airway shunt. J Appl Physiol 1985; 59: 1790-1795. (Pubitemid 16158253)
    • (1985) Journal of Applied Physiology , vol.59 , Issue.6 , pp. 1790-1795
    • Peslin, R.1    Duvivier, C.2    Didelon, J.3    Gallina, C.4
  • 20
    • 0028270331 scopus 로고
    • Input respiratory impedance to estimate airway hyperreactivity in children: Standard method versus head generator
    • Marchal F, Mazurek H, Habib M, Duvivier C, Derelle J, Peslin R,. Input respiratory impedance to estimate airway hyperreactivity in children: standard method versus head generator. Eur Respir J 1994; 7: 601-607. (Pubitemid 24099022)
    • (1994) European Respiratory Journal , vol.7 , Issue.3 , pp. 601-607
    • Marchal, F.1    Mazurek, H.2    Habib, M.3    Duvivier, C.4    Derelle, J.5    Peslin, R.6
  • 22
    • 0032957596 scopus 로고    scopus 로고
    • Assessment of bronchial reactivity by forced oscillation admittance avoids the upper airway artefact
    • DOI 10.1034/j.1399-3003.1999.13d11.x
    • Farre R, Rotger M, Marchal F, Peslin R, Navajas D,. Assessment of bronchial reactivity by forced oscillation admittance avoids the upper airway artefact. Eur Respir J 1999; 13: 761-766. (Pubitemid 29234775)
    • (1999) European Respiratory Journal , vol.13 , Issue.4 , pp. 761-766
    • Farre, R.1    Rotger, M.2    Marchal, F.3    Peslin, R.4    Navajas, D.5
  • 25
    • 0033835689 scopus 로고    scopus 로고
    • Deep inspiration-induced bronchoprotection is stronger than bronchodilation
    • Scichilone N, Kapsali T, Permutt S, Togias A,. Deep inspiration-induced bronchoprotection is stronger than bronchodilation. Am J Respir Crit Care Med 2000; 162: 910-916.
    • (2000) Am J Respir Crit Care Med , vol.162 , pp. 910-916
    • Scichilone, N.1    Kapsali, T.2    Permutt, S.3    Togias, A.4