메뉴 건너뛰기




Volumn 5, Issue 1, 2011, Pages 1171-1176

Reproducibility of retinal circulation measurements obtained using laser speckle flowgraphy-NAVI in patients with glaucoma

Author keywords

Ocular circulation; Optic nerve; Reproducibility; Retina

Indexed keywords

ADULT; ARTICLE; BLOOD FLOWMETRY; CHOROID; CLINICAL ARTICLE; FEMALE; GLAUCOMA; HUMAN; IMAGE ANALYSIS; LASER SPECKLE FLOWGRAPHY NAVI; MALE; OPTIC DISK; REPRODUCIBILITY; RETINA ARTERY; RETINA BLOOD FLOW; RETINA VEIN;

EID: 81055129596     PISSN: 11775467     EISSN: 11775483     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (153)

References (32)
  • 1
    • 0029980777 scopus 로고    scopus 로고
    • Number of people with glaucoma worldwide
    • Quigley HA. Number of people with glaucoma worldwide. Br J Ophthalmol. 1996;80(5):389-393.
    • (1996) Br J Ophthalmol , vol.80 , Issue.5 , pp. 389-393
    • Quigley, H.A.1
  • 2
    • 9644283089 scopus 로고    scopus 로고
    • Global data on visual impairment in the year 2002
    • Resnikoff S, Pascolini D, Etyàale D, et al. Global data on visual impairment in the year 2002. Bull World Health Organ. 2004;82(11): 844-851.
    • (2004) Bull World Health Organ , vol.82 , Issue.11 , pp. 844-851
    • Resnikoff, S.1    Pascolini, D.2    Etyàale, D.3
  • 3
    • 0042360494 scopus 로고    scopus 로고
    • Risk factors associated with the incidence of open-angle glaucoma: The visual impairment project
    • Le A, Mukesh BN, McCarty CA, Taylor HR. Risk factors associated with the incidence of open-angle glaucoma: the visual impairment project. Invest Ophthalmol Vis Sci. 2003;44(9):3783-3789.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , Issue.9 , pp. 3783-3789
    • Le, A.1    Mukesh, B.N.2    McCarty, C.A.3    Taylor, H.R.4
  • 4
    • 33747879306 scopus 로고    scopus 로고
    • Risk factors for open-angle glaucoma in a Japanese population: The Tajimi Study
    • Suzuki Y, Iwase A, Araie M, et al. Risk factors for open-angle glaucoma in a Japanese population: the Tajimi Study. Ophthalmology. 2006; 113(9):1613-1617.
    • (2006) Ophthalmology , vol.113 , Issue.9 , pp. 1613-1617
    • Suzuki, Y.1    Iwase, A.2    Araie, M.3
  • 5
    • 77950805154 scopus 로고    scopus 로고
    • Blood pressure, perfusion pressure, and glaucoma
    • Caprioli J, Coleman AL. Blood pressure, perfusion pressure, and glaucoma. Am J Ophthalmol. 2010;149(5):704-712.
    • (2010) Am J Ophthalmol , vol.149 , Issue.5 , pp. 704-712
    • Caprioli, J.1    Coleman, A.L.2
  • 6
    • 78649410483 scopus 로고    scopus 로고
    • Vascular reactivity of optic nerve head and retinal blood vessels in glaucoma - a review
    • Venkataraman ST, Flanagan JG, Hudson C. Vascular reactivity of optic nerve head and retinal blood vessels in glaucoma - a review. Microcirculation. 2010;17(7):568-581.
    • (2010) Microcirculation , vol.17 , Issue.7 , pp. 568-581
    • Venkataraman, S.T.1    Flanagan, J.G.2    Hudson, C.3
  • 7
    • 56149088659 scopus 로고    scopus 로고
    • The circadian variations in systemic blood pressure, ocular perfusion pressure, and ocular blood flow: Risk factors for glaucoma?
    • Werne A, Harris A, Moore D, BenZion I, Siesky B. The circadian variations in systemic blood pressure, ocular perfusion pressure, and ocular blood flow: risk factors for glaucoma? Surv Ophthalmol. 2008;53(6): 559-567.
    • (2008) Surv Ophthalmol , vol.53 , Issue.6 , pp. 559-567
    • Werne, A.1    Harris, A.2    Moore, D.3    Benzion, I.4    Siesky, B.5
  • 9
    • 33645111380 scopus 로고    scopus 로고
    • Fluorescein filling defects of the optic nerve head in normal tension glaucoma, primary open-angle glaucoma, ocular hypertension and healthy controls
    • Plange N, Kaup M, Huber K, Remky A, Arend O. Fluorescein filling defects of the optic nerve head in normal tension glaucoma, primary open-angle glaucoma, ocular hypertension and healthy controls. Ophthalmic Physiol Opt. 2006;26(1):26-32.
    • (2006) Ophthalmic Physiol Opt , vol.26 , Issue.1 , pp. 26-32
    • Plange, N.1    Kaup, M.2    Huber, K.3    Remky, A.4    Arend, O.5
  • 10
    • 0842348753 scopus 로고    scopus 로고
    • Fluorescein filling defects and quantitative morphologic analysis of the optic nerve head in glaucoma
    • Plange N, Kaup M, Weber A, Remky A, Arend O. Fluorescein filling defects and quantitative morphologic analysis of the optic nerve head in glaucoma. Arch Ophthalmol. 2004;122(2):195-201.
    • (2004) Arch Ophthalmol , vol.122 , Issue.2 , pp. 195-201
    • Plange, N.1    Kaup, M.2    Weber, A.3    Remky, A.4    Arend, O.5
  • 11
    • 33746634343 scopus 로고    scopus 로고
    • Topography and fluorescein angiography of the optic nerve head in primary openangle and chronic primary angle closure glaucoma
    • Sihota R, Saxena R, Taneja N, Venkatesh P, Sinha A. Topography and fluorescein angiography of the optic nerve head in primary openangle and chronic primary angle closure glaucoma. Optom Vis Sci. 2006;83(7):520-526.
    • (2006) Optom Vis Sci , vol.83 , Issue.7 , pp. 520-526
    • Sihota, R.1    Saxena, R.2    Taneja, N.3    Venkatesh, P.4    Sinha, A.5
  • 12
    • 0018974170 scopus 로고
    • Fluorescein angiography of the optic disc. A longitudinal follow-up study
    • Talusan ED, Schwartz B, Wilcox LM Jr. Fluorescein angiography of the optic disc. A longitudinal follow-up study. Arch Ophthalmol. 1980;98(9):1579-1587.
    • (1980) Arch Ophthalmol , vol.98 , Issue.9 , pp. 1579-1587
    • Talusan, E.D.1    Schwartz, B.2    Wilcox Jr., L.M.3
  • 13
    • 65249146643 scopus 로고    scopus 로고
    • Effect of unoprostone on topographic and blood flow changes in the ischemic optic nerve head of rabbits
    • Sugiyama T, Mashima Y, Yoshioka Y, Oku H, Ikeda T. Effect of unoprostone on topographic and blood flow changes in the ischemic optic nerve head of rabbits. Arch Ophthalmol. 2009;127(4):454-459.
    • (2009) Arch Ophthalmol , vol.127 , Issue.4 , pp. 454-459
    • Sugiyama, T.1    Mashima, Y.2    Yoshioka, Y.3    Oku, H.4    Ikeda, T.5
  • 14
    • 0033864774 scopus 로고    scopus 로고
    • Measurement of microcirculation in the optic nerve head by laser speckle flowgraphy and scanning laser Doppler flowmetry
    • Yaoeda K, Shirakashi M, Funaki S, Funaki H, Nakatsue T, Abe H. Measurement of microcirculation in the optic nerve head by laser speckle flowgraphy and scanning laser Doppler flowmetry. Am J Ophthalmol. 2000;129(6):734-739.
    • (2000) Am J Ophthalmol , vol.129 , Issue.6 , pp. 734-739
    • Yaoeda, K.1    Shirakashi, M.2    Funaki, S.3    Funaki, H.4    Nakatsue, T.5    Abe, H.6
  • 15
    • 0029120980 scopus 로고
    • Comparison of flow velocity of ophthalmic artery between primary open angle glaucoma and normal tension glaucoma
    • Yamazaki Y, Hayamizu F. Comparison of flow velocity of ophthalmic artery between primary open angle glaucoma and normal tension glaucoma. Br J Ophthalmol. 1995;79(8):732-734.
    • (1995) Br J Ophthalmol , vol.79 , Issue.8 , pp. 732-734
    • Yamazaki, Y.1    Hayamizu, F.2
  • 16
    • 0030761344 scopus 로고    scopus 로고
    • The relationship between progression of visual field defects and retrobulbar circulation in patients with glaucoma
    • Yamazaki Y, Drance SM. The relationship between progression of visual field defects and retrobulbar circulation in patients with glaucoma. Am J Ophthalmol. 1997;124(3):287-295.
    • (1997) Am J Ophthalmol , vol.124 , Issue.3 , pp. 287-295
    • Yamazaki, Y.1    Drance, S.M.2
  • 18
    • 79952241032 scopus 로고    scopus 로고
    • In vivo measurement of blood velocity in human major retinal vessels using the laser speckle method
    • Nagahara M, Tamaki Y, Tomidokoro A, Araie M. In vivo measurement of blood velocity in human major retinal vessels using the laser speckle method. Invest Ophthalmol Vis Sci. 2011;52(1):87-92.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , Issue.1 , pp. 87-92
    • Nagahara, M.1    Tamaki, Y.2    Tomidokoro, A.3    Araie, M.4
  • 19
    • 0027250451 scopus 로고
    • An application of laser speckle phenomenon for noninvasive two-dimensional evaluation of microcirculation in ocular fundus - a preliminary report
    • Tamaki Y, Kawamoto E, Araie M, Eguchi S, Fujii H. An application of laser speckle phenomenon for noninvasive two-dimensional evaluation of microcirculation in ocular fundus - a preliminary report. Jpn J Ophthalmol. 1993;37(2):178-186.
    • (1993) Jpn J Ophthalmol , vol.37 , Issue.2 , pp. 178-186
    • Tamaki, Y.1    Kawamoto, E.2    Araie, M.3    Eguchi, S.4    Fujii, H.5
  • 20
    • 0028148886 scopus 로고
    • Noncontact, twodimensional measurement of retinal microcirculation using laser speckle phenomenon
    • Tamaki Y, Araie M, Kawamoto E, Eguchi S, Fujii H. Noncontact, twodimensional measurement of retinal microcirculation using laser speckle phenomenon. Invest Ophthalmol Vis Sci. 1994;35(11):3825-3834.
    • (1994) Invest Ophthalmol Vis Sci , vol.35 , Issue.11 , pp. 3825-3834
    • Tamaki, Y.1    Araie, M.2    Kawamoto, E.3    Eguchi, S.4    Fujii, H.5
  • 21
    • 0028951869 scopus 로고
    • Non-contact, two-dimensional measurement of tissue circulation in choroid and optic nerve head using laser speckle phenomenon
    • Tamaki Y, Araie M, Kawamoto E, Eguchi S, Fujii H. Non-contact, two-dimensional measurement of tissue circulation in choroid and optic nerve head using laser speckle phenomenon. Exp Eye Res. 1995; 60(4):373-383.
    • (1995) Exp Eye Res , vol.60 , Issue.4 , pp. 373-383
    • Tamaki, Y.1    Araie, M.2    Kawamoto, E.3    Eguchi, S.4    Fujii, H.5
  • 22
    • 0033766935 scopus 로고    scopus 로고
    • Measurement of microcirculation in optic nerve head by laser speckle flowgraphy in normal volunteers
    • Yaoeda K, Shirakashi M, Funaki S, et al. Measurement of microcirculation in optic nerve head by laser speckle flowgraphy in normal volunteers. Am J Ophthalmol. 2000;130(5):606-610.
    • (2000) Am J Ophthalmol , vol.130 , Issue.5 , pp. 606-610
    • Yaoeda, K.1    Shirakashi, M.2    Funaki, S.3
  • 23
    • 0036662524 scopus 로고    scopus 로고
    • New laser speckle flowgraphy system using CCD camera
    • Konishi N, Tokimoto Y, Kohra K, Fujii H. New laser speckle flowgraphy system using CCD camera. Opt Rev. 2002;9(4):163-169.
    • (2002) Opt Rev , vol.9 , Issue.4 , pp. 163-169
    • Konishi, N.1    Tokimoto, Y.2    Kohra, K.3    Fujii, H.4
  • 24
    • 48249103168 scopus 로고    scopus 로고
    • Imaging of choroidal hemodynamics in eyes with polypoidal choroidal vasculopathy using laser speckle phenomenon
    • Watanabe G, Fujii H, Kishi S. Imaging of choroidal hemodynamics in eyes with polypoidal choroidal vasculopathy using laser speckle phenomenon. Jpn J Ophthalmol. 2008;52(3):175-181.
    • (2008) Jpn J Ophthalmol , vol.52 , Issue.3 , pp. 175-181
    • Watanabe, G.1    Fujii, H.2    Kishi, S.3
  • 25
    • 65549133833 scopus 로고    scopus 로고
    • Impact of systemic blood pressure on the relationship between intraocular pressure and blood flow in the optic nerve head of nonhuman primates
    • Liang Y, Downs JC, Fortune B, Cull G, Cioffi GA, Wang L. Impact of systemic blood pressure on the relationship between intraocular pressure and blood flow in the optic nerve head of nonhuman primates. Invest Ophthalmol Vis Sci. 2009;50(5):2154-2160.
    • (2009) Invest Ophthalmol Vis Sci , vol.50 , Issue.5 , pp. 2154-2160
    • Liang, Y.1    Downs, J.C.2    Fortune, B.3    Cull, G.4    Cioffi, G.A.5    Wang, L.6
  • 27
    • 77953367234 scopus 로고    scopus 로고
    • Reproducibility of measurements and variability of the classification algorithm of Stratus OCT in normal, hypertensive, and glaucomatous patients
    • Anton A, Castany M, Pazos-Lopez M, Cuadrado R, Flores A, Castilla M. Reproducibility of measurements and variability of the classification algorithm of Stratus OCT in normal, hypertensive, and glaucomatous patients. Clin Ophthalmol. 2009;3:139-145.
    • (2009) Clin Ophthalmol , vol.3 , pp. 139-145
    • Anton, A.1    Castany, M.2    Pazos-Lopez, M.3    Cuadrado, R.4    Flores, A.5    Castilla, M.6
  • 28
    • 23244456347 scopus 로고    scopus 로고
    • Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes
    • Budenz DL, Chang RT, Huang X, Knighton RW, Tielsch JM. Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes. Invest Ophthalmol Vis Sci. 2005;46(7):2440-2443.
    • (2005) Invest Ophthalmol Vis Sci , vol.46 , Issue.7 , pp. 2440-2443
    • Budenz, D.L.1    Chang, R.T.2    Huang, X.3    Knighton, R.W.4    Tielsch, J.M.5
  • 29
    • 41149149872 scopus 로고    scopus 로고
    • Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes
    • Budenz DL, Fredette MJ, Feuer WJ, Anderson DR. Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes. Ophthalmology. 2008;115(4):661-666. e4.
    • (2008) Ophthalmology , vol.115 , Issue.4
    • Budenz, D.L.1    Fredette, M.J.2    Feuer, W.J.3    Anderson, D.R.4
  • 30
    • 57949101661 scopus 로고    scopus 로고
    • Improved reproducibility of retinal nerve fiber layer thickness measurements with the repeat-scan protocol using the Stratus OCT in normal and glaucomatous eyes
    • Tzamalis A, Kynigopoulos M, Schlote T, Haefliger I. Improved reproducibility of retinal nerve fiber layer thickness measurements with the repeat-scan protocol using the Stratus OCT in normal and glaucomatous eyes. Graefes Arch Clin Exp Ophthalmol. 2009;247(2):245-252.
    • (2009) Graefes Arch Clin Exp Ophthalmol , vol.247 , Issue.2 , pp. 245-252
    • Tzamalis, A.1    Kynigopoulos, M.2    Schlote, T.3    Haefliger, I.4
  • 31
    • 0030914621 scopus 로고    scopus 로고
    • Realtime measurement of human optic nerve head and choroid circulation, using the laser speckle phenomenon
    • Tamaki Y, Araie M, Tomita K, Nagahara M, Tomidokoro A, Fujii H. Realtime measurement of human optic nerve head and choroid circulation, using the laser speckle phenomenon. Jpn J Ophthalmol. 1997;41(1):49-54.
    • (1997) Jpn J Ophthalmol , vol.41 , Issue.1 , pp. 49-54
    • Tamaki, Y.1    Araie, M.2    Tomita, K.3    Nagahara, M.4    Tomidokoro, A.5    Fujii, H.6
  • 32
    • 58149260765 scopus 로고    scopus 로고
    • Reproducibility of nerve fiber layer thickness measurements using 3D fourier-domain OCT
    • Menke MN, Knecht P, Sturm V, Dabov S, Funk J. Reproducibility of nerve fiber layer thickness measurements using 3D fourier-domain OCT. Invest Ophthalmol Vis Sci. 2008;49(12):5386-5391.
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , Issue.12 , pp. 5386-5391
    • Menke, M.N.1    Knecht, P.2    Sturm, V.3    Dabov, S.4    Funk, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.