메뉴 건너뛰기




Volumn 7, Issue 3, 2011, Pages 130-134

Pre-emptively pausing ultrafiltration to minimise dialysis hypotension

Author keywords

Haemodialysis; Hypotension; IDH; Mean arterial pressure MAP; Nursing

Indexed keywords


EID: 81055125628     PISSN: 18323804     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (28)
  • 1
    • 0035152152 scopus 로고    scopus 로고
    • Determinants of mean arterial pressure and pulse pressure in chronic haemodialysis patients
    • DOI 10.1038/sj.jhh.1001273
    • Abdelfatah AB, Motte G, Ducloux D & Chalopin JM (2001). Determinants of mean arterial pressure and pulse pressure in chronic haemodialysis patients. Journal of Human Hypertension, 15(11), 775-779. (Pubitemid 33054200)
    • (2001) Journal of Human Hypertension , vol.15 , Issue.11 , pp. 775-779
    • Abdelfatah, A.B.1    Motte, G.2    Ducloux, D.3    Chalopin, J.M.4
  • 2
    • 39049191749 scopus 로고    scopus 로고
    • Intradialytic hypotension: The role of volemia
    • Basile C (2006). [Intradialytic hypotension: The role of volemia]. Giornale Italiano di Nefrologia, 23(1), 22-28.
    • (2006) Giornale Italiano di Nefrologia , vol.23 , Issue.1 , pp. 22-28
    • Basile, C.1
  • 3
    • 81055132959 scopus 로고    scopus 로고
    • Mean arterial pressure measurement as an intradialytic assessment tool: A plausible and innovative adjunct to blood pressure monitoring
    • 2-5 June, Paper presented at the, Queensland, Australia
    • Bradshaw W (2010, 2-5 June). Mean arterial pressure measurement as an intradialytic assessment tool: A plausible and innovative adjunct to blood pressure monitoring. Paper presented at the Renal Society of Australasia Conference, Queensland, Australia.
    • (2010) Renal Society of Australasia Conference
    • Bradshaw, W.1
  • 4
    • 57749175308 scopus 로고    scopus 로고
    • The advantages and challenges of increasing the duration and the frequency of maintenance dialysis sessions
    • Chazot C & Jean G (2009). The advantages and challenges of increasing the duration and the frequency of maintenance dialysis sessions. Nature Clinical Practice Nephrology, 5, 34-43.
    • (2009) Nature Clinical Practice Nephrology , vol.5 , pp. 34-43
    • Chazot, C.1    Jean, G.2
  • 5
    • 65449183779 scopus 로고    scopus 로고
    • Cool dialysate reduces asymptomatic intradialytic hypotension and increases baroreflex variability
    • Chesterton LJ, Selby NM, Burton JO & McIntyre CW (2009). Cool dialysate reduces asymptomatic intradialytic hypotension and increases baroreflex variability. Hemodialysis International, 13(2), 189-196.
    • (2009) Hemodialysis International , vol.13 , Issue.2 , pp. 189-196
    • Chesterton, L.J.1    Selby, N.M.2    Burton, J.O.3    McIntyre, C.W.4
  • 7
    • 0034780316 scopus 로고    scopus 로고
    • Pathophysiology of dialysis hypotension: An update
    • Daugirdas JT (2001). Pathophysiology of dialysis hypotension: An update. American Journal of Kidney Disease, 38(4 Suppl 4), S11-17. (Pubitemid 32976704)
    • (2001) American Journal of Kidney Diseases , vol.38 , Issue.4 SUPPL. 4
    • Daugirdas, J.T.1
  • 8
    • 67649625309 scopus 로고    scopus 로고
    • Can advances in hemodialysis machine technology prevent intradialytic hypotension?
    • Davenport A (2009). Can advances in hemodialysis machine technology prevent intradialytic hypotension? Seminars in Dialysis, 22(3), 231-236.
    • (2009) Seminars in Dialysis , vol.22 , Issue.3 , pp. 231-236
    • Davenport, A.1
  • 9
    • 40049108283 scopus 로고    scopus 로고
    • Achieving blood pressure targets during dialysis improves control but increases intradialytic hypotension
    • DOI 10.1038/sj.ki.5002745, PII 5002745
    • Davenport,A, Cox C & Thuraisingham R (2008). Achieving blood pressure targets during dialysis improves control but increases intradialytic hypotension. Kidney International, 73(6), 759-764. (Pubitemid 351323255)
    • (2008) Kidney International , vol.73 , Issue.6 , pp. 759-764
    • Davenport, A.1    Cox, C.2    Thuraisingham, R.3
  • 11
    • 40949097355 scopus 로고    scopus 로고
    • Dialysis-induced hypotension is associated with impaired aortic elasticity in patients undergoing chronic hemodialysis
    • DOI 10.1097/MBP.0b013e3282f13f75, PII 0012609720080400000002
    • Duman D, Demirtunc R, Erdogan B, Sahin GM & Karadag B (2008). Dialysisinduced hypotension is associated with impaired aortic elasticity in patients undergoing chronic hemodialysis. Blood Pressure Monitoring, 13(2), 73-78. (Pubitemid 351416906)
    • (2008) Blood Pressure Monitoring , vol.13 , Issue.2 , pp. 73-78
    • Duman, D.1    Demirtunc, R.2    Erdogan, B.3    Sahin, G.M.4    Karadag, B.5
  • 13
    • 70049116811 scopus 로고    scopus 로고
    • Getting evidence into practice: Understanding knowledge translation to achieve practice change
    • Kent B, Hutchinson AM & Fineout-Overholt E (2009). Getting evidence into practice: Understanding knowledge translation to achieve practice change. Worldviews on Evidence-Based Nursing, 6(3), 183-185.
    • (2009) Worldviews on Evidence-Based Nursing , vol.6 , Issue.3 , pp. 183-185
    • Kent, B.1    Hutchinson, A.M.2    Fineout-Overholt, E.3
  • 14
    • 0942287073 scopus 로고    scopus 로고
    • A Randomized, Controlled Trial of Albumin versus Saline for the Treatment of Intradialytic Hypotension
    • DOI 10.1097/01.ASN.0000108971.98071.F2
    • Knoll GA, Grabowski JA, Dervin GF & O'Rourke K (2004). A randomized, controlled trial of albumin versus saline for the treatment of intradialytic hypotension. Journal of the American Society of Nephrology, 15(2), 487-492. (Pubitemid 38140791)
    • (2004) Journal of the American Society of Nephrology , vol.15 , Issue.2 , pp. 487-492
    • Knoll, G.A.1    Grabowski, J.A.2    Dervin, G.F.3    O'Rourke, K.4
  • 15
    • 0036561998 scopus 로고    scopus 로고
    • Isothermic dialysis for hypotension-prone patients
    • DOI 10.1046/j.1525-139X.2002.00061.x
    • Maggiore Q (2002). Isothermic dialysis for hypotension-prone patients. Seminars in Dialysis, 15(3), 187-190. (Pubitemid 41765929)
    • (2002) Seminars in Dialysis , vol.15 , Issue.3 , pp. 187-190
    • Maggiore, Q.1
  • 17
    • 30344451393 scopus 로고    scopus 로고
    • The effect of sodium profiling and feedback technologies on plasma conductivity and ionic mass balance: A study in hypotension-prone dialysis patients
    • DOI 10.1093/ndt/gfi118
    • Moret K, Aalten J, van den Wall Bake W, Gerlag P, Beerenhout C, van der Sande F et al. (2006). The effect of sodium profiling and feedback technologies on plasma conductivity and ionic mass balance: A study in hypotension-prone dialysis patients. Nephrology Dialysis Transplantation, 21(1), 138-144. (Pubitemid 43057122)
    • (2006) Nephrology Dialysis Transplantation , vol.21 , Issue.1 , pp. 138-144
    • Moret, K.1    Aalten, J.2    Van Den Wall Bake, W.3    Gerlag, P.4    Beerenhout, C.5    Van Der Sande, F.6    Leunissen, K.7    Kooman, J.8
  • 20
    • 38149124614 scopus 로고    scopus 로고
    • Recent advances in the prevention and management of intradialytic hypotension
    • Palmer BF & Henrich WL (2008). Recent advances in the prevention and management of intradialytic hypotension. Journal of the American Society of Nephrology, 19(1), 8-11.
    • (2008) Journal of the American Society of Nephrology , vol.19 , Issue.1 , pp. 8-11
    • Palmer, B.F.1    Henrich, W.L.2
  • 21
    • 42949158410 scopus 로고    scopus 로고
    • How can we improve symptomatic hypotension in hemodialysis patients: Cold dialysis vs isothermic dialysis
    • Ramos R, Soto C, Mestres R, Jara J, Zequera H, Merello JI et al. (2007). [How can we improve symptomatic hypotension in hemodialysis patients: Cold dialysis vs isothermic dialysis]. Nefrologia, 27(6), 737-741.
    • (2007) Nefrologia , vol.27 , Issue.6 , pp. 737-741
    • Ramos, R.1    Soto, C.2    Mestres, R.3    Jara, J.4    Zequera, H.5    Merello, J.I.6
  • 22
    • 33645507975 scopus 로고    scopus 로고
    • Longer treatment time and slower ultrafiltration in hemodialysis: Associations with reduced mortality in the DOPPS
    • Saran R, Bragg-Gresham JL, Levin NW, Twardowski ZJ, Wizemann V, Saito A et al. (2006). Longer treatment time and slower ultrafiltration in hemodialysis: Associations with reduced mortality in the DOPPS. Kidney International, 69(7), 1222-1228.
    • (2006) Kidney International , vol.69 , Issue.7 , pp. 1222-1228
    • Saran, R.1    Bragg-Gresham, J.L.2    Levin, N.W.3    Twardowski, Z.J.4    Wizemann, V.5    Saito, A.6
  • 23
    • 4344704654 scopus 로고    scopus 로고
    • Hemodialysis-associated hypotension as an independent risk factor for two-year mortality in hemodialysis patients
    • DOI 10.1111/j.1523-1755.2004.00812.x
    • Shoji T, Tsubakihara Y, Fujii M & Imai E (2004). Hemodialysis- associated hypotension as an independent risk factor for two-year mortality in hemodialysis patients Kidney International, 66, 1212-1220. (Pubitemid 39121031)
    • (2004) Kidney International , vol.66 , Issue.3 , pp. 1212-1220
    • Shoji, T.1    Tsubakihara, Y.2    Fujii, M.3    Imai, E.4
  • 24
    • 0036702696 scopus 로고    scopus 로고
    • Barriers to research utilisation: The clinical setting and nurses themselves
    • Sitzia J (2002). Barriers to research utilisation: The clinical setting and nurses themselves. Intensive and Critical Care Nursing, 18(4), 230-243.
    • (2002) Intensive and Critical Care Nursing , vol.18 , Issue.4 , pp. 230-243
    • Sitzia, J.1
  • 26
    • 55949089406 scopus 로고    scopus 로고
    • Dialysis induced hypotension: A serious clinical problem in renal replacement therapy
    • Sulowicz W & Radziszewski A (2007). Dialysis induced hypotension: A serious clinical problem in renal replacement therapy. Medicinski Pregled, 60(Suppl 2), 14-20.
    • (2007) Medicinski Pregled , vol.60 , Issue.SUPPL. 2 , pp. 14-20
    • Sulowicz, W.1    Radziszewski, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.