메뉴 건너뛰기




Volumn 46, Issue 9, 2011, Pages 765-771

The 4th international comparison on EPR dosimetry with tooth enamel: Part 1: Report on the results

(38)  Fattibene, P a   Wieser, A b   Adolfsson, E c   Benevides, L A d   Brai, M e   Callens, F f   Chumak, V g   Ciesielski, B h   Della Monaca, S a,i   Emerich, K h,j   Gustafsson, H c   Hirai, Y k   Hoshi, M l   Israelsson, A c   Ivannikov, A m   Ivanov, D n   Kaminska, J h   Ke, Wu o   Lund, E c   Marrale, M e   more..


Author keywords

Detection limit; Electron paramagnetic resonance (EPR); Retrospective dosimetry; Tooth enamel

Indexed keywords

AIR KERMA; CALIBRATION CURVES; CALIBRATION SAMPLES; DETECTION LIMITS; ELECTRON PARAMAGNETIC RESONANCE (EPR); EPR DOSIMETRY; EPR SIGNALS; HELMHOLTZ; IN-VITRO; INTERNATIONAL COMPARISON; MEAN VALUES; MOLAR TEETH; PERFORMANCE PARAMETERS; POWDER SAMPLES; RETROSPECTIVE DOSIMETRY; SIGNAL RESPONSE;

EID: 80955177650     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2011.05.001     Document Type: Conference Paper
Times cited : (67)

References (16)
  • 2
    • 2942572865 scopus 로고    scopus 로고
    • Detection and quantification limits: Basic concepts, international harmonization, and outstanding ('low-level') issues
    • DOI 10.1016/j.apradiso.2004.03.036, PII S0969804304000971
    • L.A. Currie Detection and quantification limits: basic concepts, international harmonization, and outstanding ("low-level") issues Appl. Radiat. Isot. 61 2004 145 149 (Pubitemid 38737047)
    • (2004) Applied Radiation and Isotopes , vol.61 , Issue.2-3 , pp. 145-149
    • Currie, L.A.1
  • 3
    • 13844271375 scopus 로고    scopus 로고
    • Electron paramagnetic resonance and fluorescence in situ hybridization-based investigations of individual doses for persons living at Metlino in the upper reaches of the Techa River
    • DOI 10.1097/01.HP.0000146612.69488.9c
    • M.O. Degteva, L.R. Anspaugh, A.V. Akleyev, P. Jacob, D.V. Ivanov, A. Wieser, M.I. Vorobiova, E.A. Shishkina, V.A. Shved, A. Vozilova, S.N. Bayankin, and B.A. Napier Electron paramagnetic resonance and fluorescence in situ hybridization-based investigations of individual doses for persons living at Metlino in the upper reaches of the Techa River Health Phys. 88 2 2005 139 153 (Pubitemid 40279124)
    • (2005) Health Physics , vol.88 , Issue.2 , pp. 139-153
    • Degteva, M.O.1    Anspaugh, L.R.2    Akleyev, A.V.3    Jacob, P.4    Ivanov, D.V.5    Wieser, A.6    Vorobiova, M.I.7    Shishkina, E.A.8    Shved, V.A.9    Vozilova, A.10    Bayankin, S.N.11    Napier, B.A.12
  • 7
    • 84898982319 scopus 로고
    • International union of pure and applied chemistry recommendations. Nomenclature in evaluation of analytical methods, including detection and quantification capabilities
    • IUPAC
    • IUPAC International union of pure and applied chemistry recommendations. Nomenclature in evaluation of analytical methods, including detection and quantification capabilities Pure Appl. Chem. 67 1995 1699 1723
    • (1995) Pure Appl. Chem. , vol.67 , pp. 1699-1723
  • 10
    • 80955180894 scopus 로고    scopus 로고
    • SOUL European Integrated Project no. FIP6R-516478
    • SOUL 2005. Southern Urals Radiation Risk Research. European Integrated Project no. FIP6R-516478.
    • (2005) Southern Urals Radiation Risk Research
  • 16
    • 0642272950 scopus 로고    scopus 로고
    • Weighted least-squares approach to calculating limits of detection and quantification by modeling variability as a function of concentration
    • M.E. Zorn, R.D. Gibbons, and W.C. Sonzogni Weighted least-squares approach to calculating limits of detection and quantification by modeling variability as a function of concentration Anal. Chem. 69 1997 3069 3075
    • (1997) Anal. Chem. , vol.69 , pp. 3069-3075
    • Zorn, M.E.1    Gibbons, R.D.2    Sonzogni, W.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.