메뉴 건너뛰기




Volumn , Issue , 2011, Pages 4980-4983

Study of a battery grid-connected discharging system which based on Boost converter

Author keywords

active inverse of crystal thyratron; battery discharge; matlab simulation

Indexed keywords

ACTIVE INVERSE OF CRYSTAL THYRATRON; ANALYSIS METHOD; BATTERY CAPACITY; BATTERY DISCHARGE; BOOST CONVERTER; DISCHARGE METHODS; DISCHARGE TESTS; GRID CONNECTED INVERTERS; GRID-CONNECTED; LOW COSTS; MATLAB SIMULATIONS; SIMULINK;

EID: 80955165081     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICECENG.2011.6057620     Document Type: Conference Paper
Times cited : (2)

References (9)
  • 3
    • 0033882605 scopus 로고    scopus 로고
    • Controller arrangement for boost converter systems sourced from solar photovoltaic arrays or other maximum power sources
    • January
    • J.A.Gow,C.D.Manning. Controller arrangement for boost converter systems sourced from solar photovoltaic arrays or other maximum power sources. IEE Proc-Electr. Power Appl. Vol 147.No 1.January 2000:15-16.
    • (2000) IEE Proc-Electr. Power Appl. , vol.147 , Issue.1 , pp. 15-16
    • Gow, J.A.1    Manning, C.D.2
  • 4
    • 3843069865 scopus 로고    scopus 로고
    • Cascaded DC-DC converter connection of photovoltaic modules[J]
    • Walker, G.R.Sernia,P.C.Cascaded DC-DC converter connection of photovoltaic modules[J]. IEEE Transaction on Power Electronics. 2004, 15(4):1130-1139.
    • (2004) IEEE Transaction on Power Electronics , vol.15 , Issue.4 , pp. 1130-1139
    • Walker, G.R.1    Sernia, P.C.2
  • 5
    • 80955151631 scopus 로고    scopus 로고
    • Photovoltaic grid-connected inverter control system based on the Boost converter [J]
    • In Chinese
    • Po Xu, Chongwei Zhang, Xing Zhang. Photovoltaic grid-connected inverter control system based on the Boost converter [J]. Application of power supply technology. 2006, 1(9):12-15(In Chinese).
    • (2006) Application of Power Supply Technology , vol.1 , Issue.9 , pp. 12-15
    • Po, X.1    Zhang, C.2    Zhang, X.3
  • 6
    • 80955134007 scopus 로고    scopus 로고
    • Application of boost circuit of battery discharge device[J]
    • In Chinese
    • Yalong Liu, Kuangcheng Li, Fuxing Wang, Yufeng Gao. Application of boost circuit of battery discharge device[J]. power supply technology. 2004,7:425-432(In Chinese).
    • (2004) Power Supply Technology , vol.7 , pp. 425-432
    • Liu, Y.1    Li, K.2    Wang, F.3    Gao, Y.4
  • 7
    • 77949461739 scopus 로고    scopus 로고
    • Implementation of Digital Increment Mode PI Algorithm in Bi-directional DC/DC Converter [J]
    • In Chinese
    • Lijun Hang, Wenxi Yao, Zhenyu Lv. Implementation of Digital Increment Mode PI Algorithm in Bi-directional DC/DC Converter [J]. power electronic technology, 2004, 38(3): 42-44(In Chinese).
    • (2004) Power Electronic Technology , vol.38 , Issue.3 , pp. 42-44
    • Hang, L.1    Yao, W.2    Lv, Z.3
  • 8
    • 80955151622 scopus 로고    scopus 로고
    • Based on single chip microcomputer PID and PWM liquid flow control system research [J]
    • In Chinese
    • Xiaoguang Li, Xiu Wang, Minzan Li. Based on single chip microcomputer PID and PWM liquid flow control system research [J]. Micro computer information(embedded and SOC), 2008, 24(2):69-71(In Chinese).
    • (2008) Micro Computer Information(embedded and SOC , vol.24 , Issue.2 , pp. 69-71
    • Li, X.1    Wang, X.2    Li, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.