-
1
-
-
0033901334
-
Transcatheter implantation of a bovine valve in pulmonary position: A lamb study
-
P. Bonhoeffer, Y. Boudjemline, and Z. Saliba Transcatheter implantation of a bovine valve in pulmonary position: a lamb study Circulation 102 2000 813 816 (Pubitemid 30643290)
-
(2000)
Circulation
, vol.102
, Issue.7
, pp. 813-816
-
-
Bonhoeffer, P.1
Boudjemline, Y.2
Saliba, Z.3
Hausse, A.O.4
Aggoun, Y.5
Bonnet, D.6
Sidi, D.7
Kachaner, J.8
-
2
-
-
24044459734
-
Percutaneous pulmonary valve implantation in humans: Results in 59 consecutive patients
-
DOI 10.1161/CIRCULATIONAHA.104.523266
-
S. Khambadkone, L. Coats, and A. Taylor Percutaneous pulmonary valve implantation in humans: results in 59 consecutive patients Circulation 112 2005 1189 1197 (Pubitemid 41216126)
-
(2005)
Circulation
, vol.112
, Issue.8
, pp. 1189-1197
-
-
Khambadkone, S.1
Coats, L.2
Taylor, A.3
Boudjemline, Y.4
Derrick, G.5
Tsang, V.6
Cooper, J.7
Muthurangu, V.8
Hegde, S.R.9
Razavi, R.S.10
Pellerin, D.11
Deanfield, J.12
Bonhoeffer, P.13
-
3
-
-
77955430081
-
Short- and medium-term outcomes after transcatheter pulmonary valve placement in the expanded multicenter US melody valve trial
-
D.B. McElhinney, W.E. Hellenbrand, and E.M. Zahn Short- and medium-term outcomes after transcatheter pulmonary valve placement in the expanded multicenter US melody valve trial Circulation 122 2010 507 516
-
(2010)
Circulation
, vol.122
, pp. 507-516
-
-
McElhinney, D.B.1
Hellenbrand, W.E.2
Zahn, E.M.3
-
4
-
-
70349996057
-
Implantation of the melody transcatheter pulmonary valve in patients with a dysfunctional right ventricular outflow tract conduit early results from the U.S. Clinical trial
-
E.M. Zahn, W.E. Hellenbrand, J.E. Lock, and D.B. McElhinney Implantation of the melody transcatheter pulmonary valve in patients with a dysfunctional right ventricular outflow tract conduit early results from the U.S. Clinical trial J Am Coll Cardiol 54 2009 1722 1729
-
(2009)
J Am Coll Cardiol
, vol.54
, pp. 1722-1729
-
-
Zahn, E.M.1
Hellenbrand, W.E.2
Lock, J.E.3
McElhinney, D.B.4
-
5
-
-
33644860328
-
Percutaneous aortic valve implantation retrograde from the femoral artery
-
J.G. Webb, M. Chandavimol, and C.R. Thompson Percutaneous aortic valve implantation retrograde from the femoral artery Circulation 113 2006 842 850
-
(2006)
Circulation
, vol.113
, pp. 842-850
-
-
Webb, J.G.1
Chandavimol, M.2
Thompson, C.R.3
-
6
-
-
77958594295
-
Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
-
PARTNER Trial Investigators
-
M.B. Leon, C.R. Smith, M. Mack PARTNER Trial Investigators Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery N Engl J Med 363 2010 1597 1607
-
(2010)
N Engl J Med
, vol.363
, pp. 1597-1607
-
-
Leon, M.B.1
Smith, C.R.2
MacK, M.3
-
7
-
-
76049128883
-
Transcatheter pulmonary valve implantation using the Edwards SAPIEN transcatheter heart valve
-
R.H. Boone, J.G. Webb, and E. Horlick Transcatheter pulmonary valve implantation using the Edwards SAPIEN transcatheter heart valve Catheter Cardiovasc Interv 75 2010 286 294
-
(2010)
Catheter Cardiovasc Interv
, vol.75
, pp. 286-294
-
-
Boone, R.H.1
Webb, J.G.2
Horlick, E.3
-
8
-
-
79959470994
-
Technique of temporary "figure-of-Eight" sutures to achieve hemostasis after removal of large-caliber femoral venous sheaths
-
M. Cilingiroglu, M. Salinger, D. Zhao, and T.E. Feldman Technique of temporary "Figure-of-Eight" sutures to achieve hemostasis after removal of large-caliber femoral venous sheaths Catheter Cardiovasc Interv 78 2011 155 160
-
(2011)
Catheter Cardiovasc Interv
, vol.78
, pp. 155-160
-
-
Cilingiroglu, M.1
Salinger, M.2
Zhao, D.3
Feldman, T.E.4
-
9
-
-
33845382806
-
Nonparametric estimation from incomplete observations
-
E.L. Kaplan, and P. Meier Nonparametric estimation from incomplete observations J Am Stat Assoc 53 1958 457 481
-
(1958)
J Am Stat Assoc
, vol.53
, pp. 457-481
-
-
Kaplan, E.L.1
Meier, P.2
-
10
-
-
0002294347
-
A simple sequentially rejective multiple test procedure
-
S. Holm A simple sequentially rejective multiple test procedure Scand J Stat 6 1979 65 70
-
(1979)
Scand J Stat
, vol.6
, pp. 65-70
-
-
Holm, S.1
-
11
-
-
79751494683
-
Bailout perventricular pulmonary valve implantation following failed percutaneous attempt using the Edwards Sapien transcatheter heart valve
-
R.J. Cubeddu, and Z.M. Hijazi Bailout perventricular pulmonary valve implantation following failed percutaneous attempt using the Edwards Sapien transcatheter heart valve Catheter Cardiovasc Interv 77 2011 276 280
-
(2011)
Catheter Cardiovasc Interv
, vol.77
, pp. 276-280
-
-
Cubeddu, R.J.1
Hijazi, Z.M.2
-
12
-
-
76849111538
-
Effect of altering pathologic right ventricular loading conditions by percutaneous pulmonary valve implantation on exercise capacity
-
P. Lurz, A. Giardini, and A.M. Taylor Effect of altering pathologic right ventricular loading conditions by percutaneous pulmonary valve implantation on exercise capacity Am J Cardiol 105 2010 721 726
-
(2010)
Am J Cardiol
, vol.105
, pp. 721-726
-
-
Lurz, P.1
Giardini, A.2
Taylor, A.M.3
-
13
-
-
1642564221
-
The congenitally bicuspid aortic valve: How does it function? Why does it fail?
-
DOI 10.1016/S0003-4975(03)01249-9
-
F. Robicsek, M.J. Thubrikar, J.W. Cook, and B. Fowler The congenitally bicuspid aortic valve: how does it function? Why does it fail? Ann Thorac Surg 77 2004 177 185 (Pubitemid 38130007)
-
(2004)
Annals of Thoracic Surgery
, vol.77
, Issue.1
, pp. 177-185
-
-
Robicsek, F.1
Thubrikar, M.J.2
Cook, J.W.3
Fowler, B.4
-
14
-
-
78651250296
-
Pre-stenting with a bare metal stent before percutaneous pulmonary valve implantation: Acute and 1-year outcomes
-
J. Nordmeyer, P. Lurz, and S. Khambadkone Pre-stenting with a bare metal stent before percutaneous pulmonary valve implantation: acute and 1-year outcomes Heart 97 2011 118 123
-
(2011)
Heart
, vol.97
, pp. 118-123
-
-
Nordmeyer, J.1
Lurz, P.2
Khambadkone, S.3
-
15
-
-
78651520483
-
One year follow-up of the multi-centre European PARTNER transcatheter heart valve study
-
PARTNER EU Investigator Group
-
T. Lefvre, A.P. Kappetein, E. Wolner PARTNER EU Investigator Group One year follow-up of the multi-centre European PARTNER transcatheter heart valve study Eur Heart J 32 2011 148 157
-
(2011)
Eur Heart J
, vol.32
, pp. 148-157
-
-
Lefvre, T.1
Kappetein, A.P.2
Wolner, E.3
-
16
-
-
34548440844
-
Preoperative thresholds for pulmonary valve replacement in patients with corrected tetralogy of Fallot using cardiovascular magnetic resonance
-
DOI 10.1161/CIRCULATIONAHA.106.659664
-
T. Oosterhof, A. van Straten, and H.W. Vliegen Preoperative thresholds for pulmonary valve replacement in patients with corrected tetralogy of Fallot using cardiovascular magnetic resonance Circulation 116 2007 545 551 (Pubitemid 47450263)
-
(2007)
Circulation
, vol.116
, Issue.5
, pp. 545-551
-
-
Oosterhof, T.1
Van Straten, A.2
Vliegen, H.W.3
Meijboom, F.J.4
Van Dijk, A.P.J.5
Spijkerboer, A.M.6
Bouma, B.J.7
Zwinderman, A.H.8
Hazekamp, M.G.9
De Roos, A.10
Mulder, B.J.M.11
-
17
-
-
54449098506
-
Biventricular response after pulmonary valve replacement for right ventricular outflow tract dysfunction: Is age a predictor of outcome?
-
A. Frigiola, V. Tsang, and C. Bull Biventricular response after pulmonary valve replacement for right ventricular outflow tract dysfunction: is age a predictor of outcome? Circulation 118 2008 S182 S190
-
(2008)
Circulation
, vol.118
-
-
Frigiola, A.1
Tsang, V.2
Bull, C.3
-
18
-
-
0037407468
-
Quantitative evaluation of susceptibility and shielding effects of nitinol, platinum, and stainless steel stents
-
Y. Wang, T.N. Truong, and C. Yen Quantitative evaluation of susceptibility and shielding effects of nitinol, platinum, and stainless steel stents Magn Reson Med 49 2003 972e6
-
(2003)
Magn Reson Med
, vol.49
-
-
Wang, Y.1
Truong, T.N.2
Yen, C.3
-
19
-
-
0034332777
-
Pulmonary valve replacement in adults late after repair of tetralogy of Fallot: Are we operating too late?
-
J. Therrien, S.C. Siu, P.R. McLaughlin, P.P. Liu, W.G. Williams, and G.D. Webb Pulmonary valve replacement in adults late after repair of tetralogy of Fallot: are we operating too late? J Am Coll Cardiol 36 2000 1670 1675
-
(2000)
J Am Coll Cardiol
, vol.36
, pp. 1670-1675
-
-
Therrien, J.1
Siu, S.C.2
McLaughlin, P.R.3
Liu, P.P.4
Williams, W.G.5
Webb, G.D.6
-
20
-
-
67649586063
-
Effective transcatheter valve implantation after pulmonary homograft failure: A new perspective on the Ross operation
-
J. Nordmeyer, P. Lurz, and V.T. Tsang Effective transcatheter valve implantation after pulmonary homograft failure: a new perspective on the Ross operation J Thorac Cardiovasc Surg 138 2009 84 88
-
(2009)
J Thorac Cardiovasc Surg
, vol.138
, pp. 84-88
-
-
Nordmeyer, J.1
Lurz, P.2
Tsang, V.T.3
|