메뉴 건너뛰기




Volumn 58, Issue 21, 2011, Pages 2248-2256

Percutaneous implantation of the Edwards SAPIEN transcatheter heart valve for conduit failure in the pulmonary position: Early phase 1 results from an international multicenter clinical trial

Author keywords

conduit; pulmonary valve replacement; SAPIEN; stent; transcatheter

Indexed keywords

ADULT; AORTA PRESSURE; ARTICLE; BODY WEIGHT; CHEMOEMBOLIZATION; CLINICAL ARTICLE; CONTROLLED STUDY; DEVICE SAFETY; DISEASE SEVERITY; FEMALE; FOLLOW UP; HEART HEMODYNAMICS; HEART RIGHT VENTRICLE OUTFLOW TRACT; HEART VENTRICLE FIBRILLATION; HUMAN; LUNG HEMORRHAGE; MALE; MULTICENTER STUDY; OPERATION DURATION; PHASE 1 CLINICAL TRIAL; PRIORITY JOURNAL; PULMONARY VALVE INSUFFICIENCY; PULMONARY VALVE REPLACEMENT; PULMONARY VALVE STENOSIS; SURGICAL EQUIPMENT; SURGICAL TECHNIQUE; TRANSCATHETER AORTIC VALVE IMPLANTATION; TREATMENT OUTCOME;

EID: 80855156725     PISSN: 07351097     EISSN: 15583597     Source Type: Journal    
DOI: 10.1016/j.jacc.2011.07.040     Document Type: Article
Times cited : (221)

References (20)
  • 3
    • 77955430081 scopus 로고    scopus 로고
    • Short- and medium-term outcomes after transcatheter pulmonary valve placement in the expanded multicenter US melody valve trial
    • D.B. McElhinney, W.E. Hellenbrand, and E.M. Zahn Short- and medium-term outcomes after transcatheter pulmonary valve placement in the expanded multicenter US melody valve trial Circulation 122 2010 507 516
    • (2010) Circulation , vol.122 , pp. 507-516
    • McElhinney, D.B.1    Hellenbrand, W.E.2    Zahn, E.M.3
  • 4
    • 70349996057 scopus 로고    scopus 로고
    • Implantation of the melody transcatheter pulmonary valve in patients with a dysfunctional right ventricular outflow tract conduit early results from the U.S. Clinical trial
    • E.M. Zahn, W.E. Hellenbrand, J.E. Lock, and D.B. McElhinney Implantation of the melody transcatheter pulmonary valve in patients with a dysfunctional right ventricular outflow tract conduit early results from the U.S. Clinical trial J Am Coll Cardiol 54 2009 1722 1729
    • (2009) J Am Coll Cardiol , vol.54 , pp. 1722-1729
    • Zahn, E.M.1    Hellenbrand, W.E.2    Lock, J.E.3    McElhinney, D.B.4
  • 5
    • 33644860328 scopus 로고    scopus 로고
    • Percutaneous aortic valve implantation retrograde from the femoral artery
    • J.G. Webb, M. Chandavimol, and C.R. Thompson Percutaneous aortic valve implantation retrograde from the femoral artery Circulation 113 2006 842 850
    • (2006) Circulation , vol.113 , pp. 842-850
    • Webb, J.G.1    Chandavimol, M.2    Thompson, C.R.3
  • 6
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • PARTNER Trial Investigators
    • M.B. Leon, C.R. Smith, M. Mack PARTNER Trial Investigators Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery N Engl J Med 363 2010 1597 1607
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    MacK, M.3
  • 7
    • 76049128883 scopus 로고    scopus 로고
    • Transcatheter pulmonary valve implantation using the Edwards SAPIEN transcatheter heart valve
    • R.H. Boone, J.G. Webb, and E. Horlick Transcatheter pulmonary valve implantation using the Edwards SAPIEN transcatheter heart valve Catheter Cardiovasc Interv 75 2010 286 294
    • (2010) Catheter Cardiovasc Interv , vol.75 , pp. 286-294
    • Boone, R.H.1    Webb, J.G.2    Horlick, E.3
  • 8
    • 79959470994 scopus 로고    scopus 로고
    • Technique of temporary "figure-of-Eight" sutures to achieve hemostasis after removal of large-caliber femoral venous sheaths
    • M. Cilingiroglu, M. Salinger, D. Zhao, and T.E. Feldman Technique of temporary "Figure-of-Eight" sutures to achieve hemostasis after removal of large-caliber femoral venous sheaths Catheter Cardiovasc Interv 78 2011 155 160
    • (2011) Catheter Cardiovasc Interv , vol.78 , pp. 155-160
    • Cilingiroglu, M.1    Salinger, M.2    Zhao, D.3    Feldman, T.E.4
  • 9
    • 33845382806 scopus 로고
    • Nonparametric estimation from incomplete observations
    • E.L. Kaplan, and P. Meier Nonparametric estimation from incomplete observations J Am Stat Assoc 53 1958 457 481
    • (1958) J Am Stat Assoc , vol.53 , pp. 457-481
    • Kaplan, E.L.1    Meier, P.2
  • 10
    • 0002294347 scopus 로고
    • A simple sequentially rejective multiple test procedure
    • S. Holm A simple sequentially rejective multiple test procedure Scand J Stat 6 1979 65 70
    • (1979) Scand J Stat , vol.6 , pp. 65-70
    • Holm, S.1
  • 11
    • 79751494683 scopus 로고    scopus 로고
    • Bailout perventricular pulmonary valve implantation following failed percutaneous attempt using the Edwards Sapien transcatheter heart valve
    • R.J. Cubeddu, and Z.M. Hijazi Bailout perventricular pulmonary valve implantation following failed percutaneous attempt using the Edwards Sapien transcatheter heart valve Catheter Cardiovasc Interv 77 2011 276 280
    • (2011) Catheter Cardiovasc Interv , vol.77 , pp. 276-280
    • Cubeddu, R.J.1    Hijazi, Z.M.2
  • 12
    • 76849111538 scopus 로고    scopus 로고
    • Effect of altering pathologic right ventricular loading conditions by percutaneous pulmonary valve implantation on exercise capacity
    • P. Lurz, A. Giardini, and A.M. Taylor Effect of altering pathologic right ventricular loading conditions by percutaneous pulmonary valve implantation on exercise capacity Am J Cardiol 105 2010 721 726
    • (2010) Am J Cardiol , vol.105 , pp. 721-726
    • Lurz, P.1    Giardini, A.2    Taylor, A.M.3
  • 13
    • 1642564221 scopus 로고    scopus 로고
    • The congenitally bicuspid aortic valve: How does it function? Why does it fail?
    • DOI 10.1016/S0003-4975(03)01249-9
    • F. Robicsek, M.J. Thubrikar, J.W. Cook, and B. Fowler The congenitally bicuspid aortic valve: how does it function? Why does it fail? Ann Thorac Surg 77 2004 177 185 (Pubitemid 38130007)
    • (2004) Annals of Thoracic Surgery , vol.77 , Issue.1 , pp. 177-185
    • Robicsek, F.1    Thubrikar, M.J.2    Cook, J.W.3    Fowler, B.4
  • 14
    • 78651250296 scopus 로고    scopus 로고
    • Pre-stenting with a bare metal stent before percutaneous pulmonary valve implantation: Acute and 1-year outcomes
    • J. Nordmeyer, P. Lurz, and S. Khambadkone Pre-stenting with a bare metal stent before percutaneous pulmonary valve implantation: acute and 1-year outcomes Heart 97 2011 118 123
    • (2011) Heart , vol.97 , pp. 118-123
    • Nordmeyer, J.1    Lurz, P.2    Khambadkone, S.3
  • 15
    • 78651520483 scopus 로고    scopus 로고
    • One year follow-up of the multi-centre European PARTNER transcatheter heart valve study
    • PARTNER EU Investigator Group
    • T. Lefvre, A.P. Kappetein, E. Wolner PARTNER EU Investigator Group One year follow-up of the multi-centre European PARTNER transcatheter heart valve study Eur Heart J 32 2011 148 157
    • (2011) Eur Heart J , vol.32 , pp. 148-157
    • Lefvre, T.1    Kappetein, A.P.2    Wolner, E.3
  • 17
    • 54449098506 scopus 로고    scopus 로고
    • Biventricular response after pulmonary valve replacement for right ventricular outflow tract dysfunction: Is age a predictor of outcome?
    • A. Frigiola, V. Tsang, and C. Bull Biventricular response after pulmonary valve replacement for right ventricular outflow tract dysfunction: is age a predictor of outcome? Circulation 118 2008 S182 S190
    • (2008) Circulation , vol.118
    • Frigiola, A.1    Tsang, V.2    Bull, C.3
  • 18
    • 0037407468 scopus 로고    scopus 로고
    • Quantitative evaluation of susceptibility and shielding effects of nitinol, platinum, and stainless steel stents
    • Y. Wang, T.N. Truong, and C. Yen Quantitative evaluation of susceptibility and shielding effects of nitinol, platinum, and stainless steel stents Magn Reson Med 49 2003 972e6
    • (2003) Magn Reson Med , vol.49
    • Wang, Y.1    Truong, T.N.2    Yen, C.3
  • 19
    • 0034332777 scopus 로고    scopus 로고
    • Pulmonary valve replacement in adults late after repair of tetralogy of Fallot: Are we operating too late?
    • J. Therrien, S.C. Siu, P.R. McLaughlin, P.P. Liu, W.G. Williams, and G.D. Webb Pulmonary valve replacement in adults late after repair of tetralogy of Fallot: are we operating too late? J Am Coll Cardiol 36 2000 1670 1675
    • (2000) J Am Coll Cardiol , vol.36 , pp. 1670-1675
    • Therrien, J.1    Siu, S.C.2    McLaughlin, P.R.3    Liu, P.P.4    Williams, W.G.5    Webb, G.D.6
  • 20
    • 67649586063 scopus 로고    scopus 로고
    • Effective transcatheter valve implantation after pulmonary homograft failure: A new perspective on the Ross operation
    • J. Nordmeyer, P. Lurz, and V.T. Tsang Effective transcatheter valve implantation after pulmonary homograft failure: a new perspective on the Ross operation J Thorac Cardiovasc Surg 138 2009 84 88
    • (2009) J Thorac Cardiovasc Surg , vol.138 , pp. 84-88
    • Nordmeyer, J.1    Lurz, P.2    Tsang, V.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.