-
1
-
-
0034594628
-
New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada
-
P. Therasse, S.G. Arbuck, and E.A. Eisenhauer New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada J Natl Cancer Inst 92 2000 205 216
-
(2000)
J Natl Cancer Inst
, vol.92
, pp. 205-216
-
-
Therasse, P.1
Arbuck, S.G.2
Eisenhauer, E.A.3
-
2
-
-
0038352143
-
Interobserver and intraobserver variability in measurement of non-small-cell carcinoma lung lesions: Implications for assessment of tumor response
-
DOI 10.1200/JCO.2003.01.144
-
J.J. Erasmus, G.W. Gladish, and L. Broemeling Interobserver and intraobserver variability in measurement of non-small-cell carcinoma lung lesions: implications for assessment of tumor response J Clin Oncol 21 2003 2574 2582 (Pubitemid 46606340)
-
(2003)
Journal of Clinical Oncology
, vol.21
, Issue.13
, pp. 2574-2582
-
-
Erasmus, J.J.1
Gladish, G.W.2
Broemeling, L.3
Sabloff, B.S.4
Truong, M.T.5
Herbst, R.S.6
Munden, R.F.7
-
3
-
-
0141925978
-
Variability in response assessment in solid tumors: Effect of number of lesions chosen for measurement
-
L.H. Schwartz, M. Mazumdar, W. Brown, A. Smith, and D.M. Panicek Variability in response assessment in solid tumors: effect of number of lesions chosen for measurement Clin Cancer Res 9 2003 4318 4323 (Pubitemid 37248386)
-
(2003)
Clinical Cancer Research
, vol.9
, Issue.12
, pp. 4318-4323
-
-
Schwartz, L.H.1
Mazumdar, M.2
Brown, W.3
Smith, A.4
Panicek, D.M.5
-
4
-
-
57849117384
-
New response evaluation criteria in solid tumours: Revised RECIST guideline (version 1.1)
-
E.A. Eisenhauer, P. Therasse, and J. Bogaerts New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1) Eur J Cancer 45 2009 228 247
-
(2009)
Eur J Cancer
, vol.45
, pp. 228-247
-
-
Eisenhauer, E.A.1
Therasse, P.2
Bogaerts, J.3
-
5
-
-
0842345498
-
Volumetric measurements of pulmonary nodules at multi-row detector CT: In vivo reproducibility
-
DOI 10.1007/s00330-003-2132-0
-
D. Wormanns, G. Kohl, and E. Klotz Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility Eur Radiol 14 2004 86 92 (Pubitemid 38181058)
-
(2004)
European Radiology
, vol.14
, Issue.1
, pp. 86-92
-
-
Wormanns, D.1
Kohl, G.2
Klotz, E.3
Marheine, A.4
Beyer, F.5
Heindel, W.6
Diederich, S.7
-
6
-
-
0034538087
-
Small pulmonary nodules: Volumetrically determined growth rates based on CT evaluation
-
D.F. Yankelevitz, A.P. Reeves, W.J. Kostis, B. Zhao, and C.I. Henschke Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation Radiology 217 2000 251 256 (Pubitemid 33097610)
-
(2000)
Radiology
, vol.217
, Issue.1
, pp. 251-256
-
-
Yankelevitz, D.F.1
Reeves, A.P.2
Kostis, W.J.3
Zhao, B.4
Henschke, C.I.5
-
7
-
-
35148874156
-
Quantitative CT-verlaufskontrolle von lebermalignomen nach RECIST und WHO im vergleich zur volumetrie
-
DOI 10.1055/s-2007-963171
-
C.P. Heussel, S. Meier, S. Wittelsberger, H. Gotte, P. Mildenberger, and H.U. Kauczor Follow-up CT measurement of liver malignoma according to RECIST and WHO vs. volumetry Rofo 179 2007 958 964 (Pubitemid 47596421)
-
(2007)
RoFo Fortschritte auf dem Gebiet der Rontgenstrahlen und der Bildgebenden Verfahren
, vol.179
, Issue.9
, pp. 958-964
-
-
Heussel, C.P.1
Meier, S.2
Wittelsberger, S.3
Gotte, H.4
Mildenberger, P.5
Kauczor, H.-U.6
-
8
-
-
33847775050
-
Software assistance for oncological therapy monitoring by volumetric assessment of tumor growth
-
L. Bornemann, V. Dicken, and J.M. Kuhnigk Software assistance for oncological therapy monitoring by volumetric assessment of tumor growth Int J Comput Assist Radiol Surg 2007 2007 231 242
-
(2007)
Int J Comput Assist Radiol Surg
, vol.2007
, pp. 231-242
-
-
Bornemann, L.1
Dicken, V.2
Kuhnigk, J.M.3
-
9
-
-
20444502226
-
New tools for computer assistance in thoracic CT: Part 2. Therapy monitoring of pulmonary metastases
-
L. Bornemann, J.M. Kuhnigk, and V. Dicken Informatics in radiology (infoRAD): new tools for computer assistance in thoracic CT part 2. Therapy monitoring of pulmonary metastases Radiographics 25 2005 841 848 (Pubitemid 40826802)
-
(2005)
Radiographics
, vol.25
, Issue.3
, pp. 841-848
-
-
Bornemann, L.1
Kuhnigk, J.-M.2
Dicken, V.3
Zidowitz, S.4
Kuemmerlen, B.5
Krass, S.6
Peitgen, H.-O.7
Wein, B.B.8
Schubert, H.9
Shin, H.-O.10
Wormanns, D.11
-
10
-
-
70149105545
-
RECIST and WHO criteria evaluation of cervical, thoracic and abdominal lymph nodes in patients with malignant lymphoma: Manual versus semi-automated measurement on standard MDCT slices
-
S. Keil, F.F. Behrendt, and S. Stanzel RECIST and WHO criteria evaluation of cervical, thoracic and abdominal lymph nodes in patients with malignant lymphoma: manual versus semi-automated measurement on standard MDCT slices Rofo 181 2009 888 895
-
(2009)
Rofo
, vol.181
, pp. 888-895
-
-
Keil, S.1
Behrendt, F.F.2
Stanzel, S.3
-
11
-
-
64249095503
-
Automated measurement of lymph nodes: A phantom study
-
S. Keil, C. Plumhans, and F.F. Behrendt Automated measurement of lymph nodes: a phantom study Eur Radiol 19 2009 1079 1086
-
(2009)
Eur Radiol
, vol.19
, pp. 1079-1086
-
-
Keil, S.1
Plumhans, C.2
Behrendt, F.F.3
-
12
-
-
0037257434
-
Artificial thorax for MR imaging studies in porcine heart-lung preparations
-
DOI 10.1148/radiol.2261011275
-
J. Biederer, and M. Heller Artificial thorax for MR imaging studies in porcine heart-lung preparations Radiology 226 2003 250 255 (Pubitemid 36163937)
-
(2003)
Radiology
, vol.226
, Issue.1
, pp. 250-255
-
-
Biederer, J.1
Heller, M.2
-
13
-
-
33645075495
-
Reproducibility of computer-aided volumetry of artificial small pulmonary nodules in ex vivo porcine lungs
-
DOI 10.1097/01.rli.0000191366.05586.4d, PII 0000442420060100000005
-
H. Bolte, C. Riedel, and T. Jahnke Reproducibility of computer-aided volumetry of artificial small pulmonary nodules in ex vivo porcine lungs Invest Radiol 41 2006 28 35 (Pubitemid 44378276)
-
(2006)
Investigative Radiology
, vol.41
, Issue.1
, pp. 28-35
-
-
Bolte, H.1
Riedel, C.2
Jahnke, T.3
Inan, N.4
Freitag, S.5
Kohl, G.6
Heller, M.7
Biederer, J.8
-
14
-
-
34147179045
-
Automated volumetry of solid pulmonary nodules in a phantom: Accuracy across different CT scanner technologies
-
DOI 10.1097/01.rli.0000258683.20123.c4, PII 0000442420070500000005
-
M. Das, G. Muhlenbruch, and M. Katoh Automated volumetry of solid pulmonary nodules in a phantom: accuracy across different CT scanner technologies Invest Radiol 42 2007 297 302 (Pubitemid 46558089)
-
(2007)
Investigative Radiology
, vol.42
, Issue.5
, pp. 297-302
-
-
Das, M.1
Muhlenbruch, G.2
Katoh, M.3
Bakai, A.4
Salganicoff, M.5
Stanzel, S.6
Mahnken, A.H.7
Gunther, R.W.8
Wildberger, J.E.9
-
15
-
-
80755132419
-
Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria
-
K. Marten, F. Auer, S. Schmidt, G. Kohl, E.J. Rummeny, and C. Engelke Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria Eur Radiol 2005 1 10
-
(2005)
Eur Radiol
, pp. 1-10
-
-
Marten, K.1
Auer, F.2
Schmidt, S.3
Kohl, G.4
Rummeny, E.J.5
Engelke, C.6
-
16
-
-
43449130684
-
Semi-automated volumetric analysis of lymph node metastases in patients with malignant melanoma stage III/IV-A feasibility study
-
M. Fabel, H. von Tengg-Kobligk, and F.L. Giesel Semi-automated volumetric analysis of lymph node metastases in patients with malignant melanoma stage III/IV-A feasibility study Eur Radiol 18 2008 1114 1122
-
(2008)
Eur Radiol
, vol.18
, pp. 1114-1122
-
-
Fabel, M.1
Von Tengg-Kobligk, H.2
Giesel, F.L.3
|