메뉴 건너뛰기




Volumn 22, Issue 12, 2011, Pages 1361-1365

Heat production during different ultrasonic and conventional osteotomy preparations for dental implants

Author keywords

Dental implantology; Intraosseus temperature development; Ultrasonic bone surgery

Indexed keywords

ANIMAL; ARTICLE; CATTLE; DENTAL EQUIPMENT; HEAT; HUMAN; INSTRUMENTATION; NONPARAMETRIC TEST; OSTEOTOMY; PIEZOSURGERY; RIB; TOOTH IMPLANTATION;

EID: 80755175782     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2010.02126.x     Document Type: Article
Times cited : (88)

References (28)
  • 3
    • 0022069236 scopus 로고
    • Thermally induced bone necrosis in rabbits: relation to implant failure in humans
    • Albrektsson, T. & Eriksson, A. (1985) Thermally induced bone necrosis in rabbits: relation to implant failure in humans. Clinical Orthopaedics and Related Research 195: 311-312.
    • (1985) Clinical Orthopaedics and Related Research , vol.195 , pp. 311-312
    • Albrektsson, T.1    Eriksson, A.2
  • 4
    • 0034446654 scopus 로고    scopus 로고
    • The effects of drilling force on cortical temperatures and their duration: an in vitro study
    • Bachus, K.N., Rondina, M.T. & Hutchinson, D.T. (2000) The effects of drilling force on cortical temperatures and their duration: an in vitro study. Medical Engineering & Physics 22: 685-691.
    • (2000) Medical Engineering & Physics , vol.22 , pp. 685-691
    • Bachus, K.N.1    Rondina, M.T.2    Hutchinson, D.T.3
  • 5
    • 77953553238 scopus 로고    scopus 로고
    • Parameters for successful implant integration revisited part I: immediate loading considered in light of the original prerequisites for osseointegration
    • Bahat, O. & Sullivan, R.M. (2010) Parameters for successful implant integration revisited part I: immediate loading considered in light of the original prerequisites for osseointegration. Clinical Implant Dentistry and Related Research 12 (Suppl. 1): e2-12.
    • (2010) Clinical Implant Dentistry and Related Research , vol.12 , Issue.SUPPL. 1
    • Bahat, O.1    Sullivan, R.M.2
  • 7
    • 0029683215 scopus 로고    scopus 로고
    • The effect of speed, pressure, and time on bone temperature during the drilling of implant sites
    • Brisman, D.L. (1996) The effect of speed, pressure, and time on bone temperature during the drilling of implant sites. The International Journal of Oral & Maxillofacial Implants 11: 35-37.
    • (1996) The International Journal of Oral & Maxillofacial Implants , vol.11 , pp. 35-37
    • Brisman, D.L.1
  • 10
    • 0034448893 scopus 로고    scopus 로고
    • Measurement of thermal conductivity of bovine cortical bone
    • Davidson, S.R. & James, D.F. (2000) Measurement of thermal conductivity of bovine cortical bone. Medical Engineering & Physics 22: 741-747.
    • (2000) Medical Engineering & Physics , vol.22 , pp. 741-747
    • Davidson, S.R.1    James, D.F.2
  • 11
    • 3042517588 scopus 로고    scopus 로고
    • The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability
    • Ercoli, C., Funkenbusch, P.D., Lee, H.J., Moss, M.E. & Graser, G.N. (2004) The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability. The International Journal of Oral & Maxillofacial Implants 19: 335-349.
    • (2004) The International Journal of Oral & Maxillofacial Implants , vol.19 , pp. 335-349
    • Ercoli, C.1    Funkenbusch, P.D.2    Lee, H.J.3    Moss, M.E.4    Graser, G.N.5
  • 12
    • 0020790218 scopus 로고
    • Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit
    • Eriksson, A.R. & Albrektsson, T. (1983) Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. Journal of Prosthetic Dentistry 50: 101-107.
    • (1983) Journal of Prosthetic Dentistry , vol.50 , pp. 101-107
    • Eriksson, A.R.1    Albrektsson, T.2
  • 13
    • 0021704071 scopus 로고
    • Heat caused by drilling cortical bone. Temperature measured in vivo in patients and animals
    • Eriksson, A.R., Albrektsson, T. & Albrektsson, B. (1984a) Heat caused by drilling cortical bone. Temperature measured in vivo in patients and animals. Acta Orthopaedica Scandinavica 55: 629-631.
    • (1984) Acta Orthopaedica Scandinavica , vol.55 , pp. 629-631
    • Eriksson, A.R.1    Albrektsson, T.2    Albrektsson, B.3
  • 14
    • 0021685213 scopus 로고
    • The effect of heat on bone regeneration: an experimental study in the rabbit using the bone growth chamber
    • Eriksson, R.A. & Albrektsson, T. (1984) The effect of heat on bone regeneration: an experimental study in the rabbit using the bone growth chamber. The International Journal of Oral and Maxillofacial Surgery 42: 705-711.
    • (1984) The International Journal of Oral and Maxillofacial Surgery , vol.42 , pp. 705-711
    • Eriksson, R.A.1    Albrektsson, T.2
  • 18
    • 0031264521 scopus 로고    scopus 로고
    • Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: relationship between drill speed and healing
    • Iyer, S., Weiss, C. & Mehta, A. (1997) Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: relationship between drill speed and healing. International Journal of Prosthodontics 10: 536-540.
    • (1997) International Journal of Prosthodontics , vol.10 , pp. 536-540
    • Iyer, S.1    Weiss, C.2    Mehta, A.3
  • 19
    • 0034173399 scopus 로고    scopus 로고
    • Influence of multiple use of Timedur-titanium cannon drills: thermal response and scanning electron microscopic findings
    • Jochum, R.M. & Reichart, P.A. (2000) Influence of multiple use of Timedur-titanium cannon drills: thermal response and scanning electron microscopic findings. Clinical Oral Implants Research 11: 139-143.
    • (2000) Clinical Oral Implants Research , vol.11 , pp. 139-143
    • Jochum, R.M.1    Reichart, P.A.2
  • 20
    • 2142653009 scopus 로고    scopus 로고
    • Effect of implant design on survival and success rates of titanium oral implants: a 10-year prospective cohort study of the ITI Dental Implant System
    • Karoussis, I.K., Bragger, U., Salvi, G.E., Burgin, W. & Lang, N.P. (2004) Effect of implant design on survival and success rates of titanium oral implants: a 10-year prospective cohort study of the ITI Dental Implant System. Clinical Oral Implants Research 15: 8-17.
    • (2004) Clinical Oral Implants Research , vol.15 , pp. 8-17
    • Karoussis, I.K.1    Bragger, U.2    Salvi, G.E.3    Burgin, W.4    Lang, N.P.5
  • 23
  • 25
    • 60049100274 scopus 로고    scopus 로고
    • Effects of irrigation temperature on heat control in vitro at different drilling depths
    • Sener, B.C., Dergin, G., Gursoy, B., Kelesoglu, E. & Slih, I. (2009) Effects of irrigation temperature on heat control in vitro at different drilling depths. Clinical Oral Implants Research 20: 294-298.
    • (2009) Clinical Oral Implants Research , vol.20 , pp. 294-298
    • Sener, B.C.1    Dergin, G.2    Gursoy, B.3    Kelesoglu, E.4    Slih, I.5
  • 28
    • 0035751049 scopus 로고    scopus 로고
    • The piezoelectric bony window osteotomy and sinus membrane elevation: introduction of a new technique for simplification of the sinus augmentation procedure
    • Vercellotti, T., De Paoli, S. & Nevins, M. (2001) The piezoelectric bony window osteotomy and sinus membrane elevation: introduction of a new technique for simplification of the sinus augmentation procedure. International Journal of Periodontics & Restorative Dentistry 21: 561-567.
    • (2001) International Journal of Periodontics & Restorative Dentistry , vol.21 , pp. 561-567
    • Vercellotti, T.1    De Paoli, S.2    Nevins, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.