Dose calculation accuracy of the monte carlo algorithm for cyberknife compared with other commercially available dose calculation algorithms

Author keywords

Cyberknife; Dose calculation; Heterogeneity corrections; Monte Carlo

Indexed keywords

ACCURACY; ALGORITHM; ARTICLE; CONTROLLED STUDY; CYBERKNIFE; DENSITY; DOSIMETRY; GAMMA RADIATION; MONTE CARLO METHOD; PHANTOM; PHOTON; PREDICTION; PRIORITY JOURNAL; RADIATION DOSE DISTRIBUTION; RADIATION SCATTERING; X RAY FILM;

EID: 80755163635     PISSN: 09583947     EISSN: 18734022     Source Type: Journal    
DOI: 10.1016/j.meddos.2010.09.001     Document Type: Article
Times cited : (13)

References (11)
  • 1
    • 77954301995 scopus 로고    scopus 로고
    • Clinical implications of adopting Monte Carlo treatment planning for cyberknife
    • Sharma S.C., et al. Clinical implications of adopting Monte Carlo treatment planning for cyberknife. J. Appl. Clin. Med. Phys. 2010, 1:170-175.
    • (2010) J. Appl. Clin. Med. Phys. , vol.1 , pp. 170-175
    • Sharma, S.C.1
  • 2
    • 15744398473 scopus 로고    scopus 로고
    • Comparison of inhomogeneity correction algorithms in small photon fields
    • Jones A.O., Das I.J. Comparison of inhomogeneity correction algorithms in small photon fields. Med. Phys. 2005, 32:766-776.
    • (2005) Med. Phys. , vol.32 , pp. 766-776
    • Jones, A.O.1    Das, I.J.2
  • 3
    • 34347393495 scopus 로고    scopus 로고
    • Impact of inhomogeneity corrections on dose coerage in the treatment of lung cancer using stereotactic body radiation therapy
    • Ding G., Duggan D.M., Lu B., et al. Impact of inhomogeneity corrections on dose coerage in the treatment of lung cancer using stereotactic body radiation therapy. Med. Phys. 2007, 34:2985-2994.
    • (2007) Med. Phys. , vol.34 , pp. 2985-2994
    • Ding, G.1    Duggan, D.M.2    Lu, B.3
  • 4
    • 44449122864 scopus 로고    scopus 로고
    • Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6MV photon fields smaller than 4 cm produced by cyberknife
    • Wilcox E., Daskalov G. Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6MV photon fields smaller than 4 cm produced by cyberknife. Med. Phys. 2008, 35:2259-2266.
    • (2008) Med. Phys. , vol.35 , pp. 2259-2266
    • Wilcox, E.1    Daskalov, G.2
  • 5
    • 37549052531 scopus 로고    scopus 로고
    • Small fields: nonequilibrium radiation dosimetry
    • Das I.J., Ding G.X., Ahnesjo A. Small fields: nonequilibrium radiation dosimetry. Med. Phys. 2008, 35:206-215.
    • (2008) Med. Phys. , vol.35 , pp. 206-215
    • Das, I.J.1    Ding, G.X.2    Ahnesjo, A.3
  • 6
    • 17844400761 scopus 로고    scopus 로고
    • Tissue inhomogeneity corrections for megavoltage photon beams
    • Medical Physics, Madison, WI
    • Papanikolaou N., et al. Tissue inhomogeneity corrections for megavoltage photon beams. AAPM Report No. 85 2004, Medical Physics, Madison, WI.
    • (2004) AAPM Report No. 85
    • Papanikolaou, N.1
  • 7
    • 33750574559 scopus 로고    scopus 로고
    • Testing of the analytical anisotropic algorithm for photon dose calculation
    • Van Esch A., Tillikainen L., Pyykkonen J., et al. Testing of the analytical anisotropic algorithm for photon dose calculation. Med. Phys. 2006, 33:4130-4148.
    • (2006) Med. Phys. , vol.33 , pp. 4130-4148
    • Van Esch, A.1    Tillikainen, L.2    Pyykkonen, J.3
  • 8
    • 0347625750 scopus 로고    scopus 로고
    • Commissioning 6 MV photon beams of a stereotactic radiosurgery system for Monte Carlo treatment planning
    • Deng J., Ma C.M., Hai J., et al. Commissioning 6 MV photon beams of a stereotactic radiosurgery system for Monte Carlo treatment planning. Med. Phys. 2003, 30:3124-3134.
    • (2003) Med. Phys. , vol.30 , pp. 3124-3134
    • Deng, J.1    Ma, C.M.2    Hai, J.3
  • 9
    • 34447325660 scopus 로고    scopus 로고
    • Design, development, and implementation of the Radiological Physics Center's pelvis and thorax anthropomorphic quality assurance phantoms
    • Followill D.S., Evans D.R., Cherry C., et al. Design, development, and implementation of the Radiological Physics Center's pelvis and thorax anthropomorphic quality assurance phantoms. Med. Phys. 2007, 34:2070-2076.
    • (2007) Med. Phys. , vol.34 , pp. 2070-2076
    • Followill, D.S.1    Evans, D.R.2    Cherry, C.3
  • 10
    • 0020038518 scopus 로고
    • Changes in the dose-profile of a 10 MV x-ray beam within and beyond low density material
    • Kornelsen R.O., Young M.E.J. Changes in the dose-profile of a 10 MV x-ray beam within and beyond low density material. Med. Phys. 1982, 9:114-116.
    • (1982) Med. Phys. , vol.9 , pp. 114-116
    • Kornelsen, R.O.1    Young, M.E.J.2
  • 11
    • 0008796868 scopus 로고    scopus 로고
    • Radiochromic film dosimetry
    • AAPM Report No. 63
    • Niroomand-Rad A., et al. Radiochromic film dosimetry. Med. Phys. 1998, 25:2093-2115. AAPM Report No. 63.
    • (1998) Med. Phys. , vol.25 , pp. 2093-2115
    • Niroomand-Rad, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.