메뉴 건너뛰기




Volumn 46, Issue 12, 2011, Pages 1458-1467

Acoustic radiation force impulse imaging (ARFI) for non-invasive detection of liver fibrosis: Examination standards and evaluation of interlobe differences in healthy subjects and chronic liver disease

Author keywords

ARFI; Liver cirrhosis; Liver fibrosis; Liver stiffness; Ultrasound

Indexed keywords

ACOUSTIC RADIATION FORCE IMPULSE IMAGING; ADULT; ANATOMICAL VARIATION; ARTICLE; CHRONIC LIVER DISEASE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DISEASE SEVERITY; ECHOGRAPHY; ELASTOGRAPHY; FEMALE; HEPATITIS C; HISTOPATHOLOGY; HUMAN; INTERLOBE DIFFERENCE; LIVER CIRRHOSIS; LIVER DISEASE; LIVER EXAMINATION; LIVER FIBROSIS; MAJOR CLINICAL STUDY; MALE; NON INVASIVE PROCEDURE; NONVIRAL LIVER DISEASE; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; TRANSIENT ELASTOGRAPHY;

EID: 80655143414     PISSN: 00365521     EISSN: 15027708     Source Type: Journal    
DOI: 10.3109/00365521.2011.610004     Document Type: Article
Times cited : (101)

References (37)
  • 1
    • 34548277150 scopus 로고    scopus 로고
    • Grading and staging systems for inflammation and fibrosis in chronic liver diseases
    • DOI 10.1016/j.jhep.2007.07.006, PII S0168827807004023
    • Goodman ZD. Grading and staging systems for inflammation and fibrosis in chronic liver diseases. J Hepatol 2007;47: 598-607. (Pubitemid 47331757)
    • (2007) Journal of Hepatology , vol.47 , Issue.4 , pp. 598-607
    • Goodman, Z.D.1
  • 2
    • 57049177569 scopus 로고    scopus 로고
    • Liver biopsy: The best, not the gold standard
    • Bedossa P, Carrat F. Liver biopsy: the best, not the gold standard. J Hepatol 2009;50:1-3.
    • (2009) J Hepatol , vol.50 , pp. 1-3
    • Bedossa, P.1    Carrat, F.2
  • 4
    • 64749084891 scopus 로고    scopus 로고
    • Reproducibility and limitations of transient elastography
    • Friedrich-Rust M, Zeuzem S. Reproducibility and limitations of transient elastography. Liver Int 2009;29:619-20.
    • (2009) Liver Int , vol.29 , pp. 619-20
    • Friedrich-Rust, M.1    Zeuzem, S.2
  • 7
    • 70249130127 scopus 로고    scopus 로고
    • Liver fibrosis in viral hepatitis: Noninvasive assessment with acoustic radiation force impulse imaging versus transient elastography
    • Friedrich-Rust M, Wunder K, Kriener S, Sotoudeh F, Richter S, Bojunga J, et al. Liver fibrosis in viral hepatitis: noninvasive assessment with acoustic radiation force impulse imaging versus transient elastography. Radiology 2009;252: 595-604.
    • (2009) Radiology , vol.252 , pp. 595-604
    • Friedrich-Rust, M.1    Wunder, K.2    Kriener, S.3    Sotoudeh, F.4    Richter, S.5    Bojunga, J.6
  • 8
    • 73949123503 scopus 로고    scopus 로고
    • Performance of a new elastographic method (ARFI technology) compared to unidimensional transient elastography in the noninvasive assessment of chronic hepatitis C. Preliminary results
    • Lupsor M, Badea R, Stefanescu H, Sparchez Z, Branda H, Serban A, et al. Performance of a new elastographic method (ARFI technology) compared to unidimensional transient elastography in the noninvasive assessment of chronic hepatitis C. Preliminary results. J Gastrointestin Liver Dis 2009; 18:303-10.
    • (2009) J Gastrointestin Liver Dis , vol.18 , pp. 303-10
    • Lupsor, M.1    Badea, R.2    Stefanescu, H.3    Sparchez, Z.4    Branda, H.5    Serban, A.6
  • 9
    • 77950602859 scopus 로고    scopus 로고
    • Evaluation of acoustic radiation force impulse elastography for fibrosis staging of chronic liver disease: A pilot study
    • Takahashi H, Ono N, Eguchi Y, Eguchi T, Kitajima Y, Kawaguchi Y, et al. Evaluation of acoustic radiation force impulse elastography for fibrosis staging of chronic liver disease: a pilot study. Liver Int 2010;30:538-45.
    • (2010) Liver Int , vol.30 , pp. 538-45
    • Takahashi, H.1    Ono, N.2    Eguchi, Y.3    Eguchi, T.4    Kitajima, Y.5    Kawaguchi, Y.6
  • 10
    • 78751515404 scopus 로고    scopus 로고
    • Acoustic radiation force impulse elastography as compared to transient elastography and liver biopsy in patients with chronic hepatopathies
    • Sporea I, Sirli RL, Deleanu A, Iulia R, Tudora A, Dan I, et al. Acoustic radiation force impulse elastography as compared to transient elastography and liver biopsy in patients with chronic hepatopathies. Ultraschall in Med 2011;32:S46-52.
    • (2011) Ultraschall in Med , vol.32
    • Sporea, I.1    Sirli, R.L.2    Deleanu, A.3    Iulia, R.4    Tudora, A.5    Dan, I.6
  • 11
    • 79955926420 scopus 로고    scopus 로고
    • Clinical feasibility of liver elastography by acoustic radiation force impulse imaging (ARFI)
    • Rifai K, Cornberg J, Mederacke I, Bahr MJ, Wedemeyer H, Malinski P, et al. Clinical feasibility of liver elastography by acoustic radiation force impulse imaging (ARFI). Dig Liver Dis 2011;43:491-7.
    • (2011) Dig Liver Dis , vol.43 , pp. 491-7
    • Rifai, K.1    Cornberg, J.2    Mederacke, I.3    Bahr, M.J.4    Wedemeyer, H.5    Malinski, P.6
  • 12
    • 79953782212 scopus 로고    scopus 로고
    • Accuracy of VirtualTouch Acoustic Radiation Force Impulse (ARFI) imaging for the diagnosis of cirrhosis during liver ultrasonography
    • Piscaglia F, Salvatore V, Di Donato R, D'Onofrio M, Gualandi S, Gallotti A, et al. Accuracy of VirtualTouch Acoustic Radiation Force Impulse (ARFI) imaging for the diagnosis of cirrhosis during liver ultrasonography. Ultra-schall Med 2011;32:167-75.
    • (2011) Ultra-schall Med , vol.32 , pp. 167-75
    • Piscaglia, F.1    Salvatore, V.2    Di Donato, R.3    D'Onofrio, M.4    Gualandi, S.5    Gallotti, A.6
  • 13
    • 77954715997 scopus 로고    scopus 로고
    • Tissue quantification with acoustic radiation force impulse imaging: Measurement repeatability and normal values in the healthy liver
    • D'Onofrio M, Gallotti A, Mucelli RP. Tissue quantification with acoustic radiation force impulse imaging: Measurement repeatability and normal values in the healthy liver. Am J Roentgenol 2010;195:132-6.
    • (2010) Am J Roentgenol , vol.195 , pp. 132-6
    • D'Onofrio, M.1    Gallotti, A.2    Mucelli, R.P.3
  • 14
    • 80755142826 scopus 로고    scopus 로고
    • An abdominal and thyroid status with acoustic radiation force impulse elastometry-a feasibility study acoustic radiation force impulse elastometry of human organs
    • DOI 10.1016/j.erad.2010.09.025
    • Goertz RS, Amann K, Heide R, Bernatik T, Neurath MF, Strobel D. An abdominal and thyroid status with acoustic radiation force impulse elastometry-a feasibility study acoustic radiation force impulse elastometry of human organs. Eur J Radiol 2010;DOI 10.1016/j.erad.2010.09.025.
    • (2010) Eur J Radiol
    • Goertz, R.S.1    Amann, K.2    Heide, R.3    Bernatik, T.4    Neurath, M.F.5    Strobel, D.6
  • 15
    • 79952467377 scopus 로고    scopus 로고
    • The mean values of liver stiffness assessed by acoustic radiation force impulse elastography in normal subjects
    • Popescu A, Sporea I, Sirli R, Bota S, Focsa M, Danila M, et al. The mean values of liver stiffness assessed by acoustic radiation force impulse elastography in normal subjects. Med Ultrason 2011;13:33-7.
    • (2011) Med Ultrason , vol.13 , pp. 33-7
    • Popescu, A.1    Sporea, I.2    Sirli, R.3    Bota, S.4    Focsa, M.5    Danila, M.6
  • 16
    • 79953790505 scopus 로고    scopus 로고
    • Noninvasive assessment of liver fibrosis with acoustic radiation force impulse imaging: Increased liver and splenic stiffness in patients with liver fibrosis and cirrhosis
    • Grgurevic I, Cikara I, Horvat J, Lukic IK, Heinzl R, Banic M, et al. Noninvasive assessment of liver fibrosis with acoustic radiation force impulse imaging: increased liver and splenic stiffness in patients with liver fibrosis and cirrhosis. Ultraschall Med 2011;32:160-6.
    • (2011) Ultraschall Med , vol.32 , pp. 160-6
    • Grgurevic, I.1    Cikara, I.2    Horvat, J.3    Lukic, I.K.4    Heinzl, R.5    Banic, M.6
  • 17
    • 79958769054 scopus 로고    scopus 로고
    • New method for assessing liver fibrosis based on acoustic radiation force impulse: A special reference to the difference between right and left liver
    • Toshima T, Shirabe K, Takeishi K, Motomura T, Mano Y, Uchiyama H, et al. New method for assessing liver fibrosis based on acoustic radiation force impulse: a special reference to the difference between right and left liver. J Gastroenterol 2011;46:705-11.
    • (2011) J Gastroenterol , vol.46 , pp. 705-11
    • Toshima, T.1    Shirabe, K.2    Takeishi, K.3    Motomura, T.4    Mano, Y.5    Uchiyama, H.6
  • 18
    • 49649118223 scopus 로고    scopus 로고
    • Estimation of stage-specific fibrosis progression rates in chronic hepatitis C virus infection: A meta-analysis and meta-regression
    • Thein HH, Yi Q, Dore GJ, Krahn MD. Estimation of stage-specific fibrosis progression rates in chronic hepatitis C virus infection: a meta-analysis and meta-regression. Hepatology 2008;48:418-31.
    • (2008) Hepatology , vol.48 , pp. 418-31
    • Thein, H.H.1    Yi, Q.2    Dore, G.J.3    Krahn, M.D.4
  • 21
    • 77955147344 scopus 로고    scopus 로고
    • Nonalcoholic fatty liver disease: US-based acoustic radiation force impulse elastography
    • Yoneda M, Suzuki K, Kato S, Fujita K, Nozaki Y, Hosono K, et al. Nonalcoholic fatty liver disease: US-based acoustic radiation force impulse elastography. Radiology 2010;256:640-7.
    • (2010) Radiology , vol.256 , pp. 640-7
    • Yoneda, M.1    Suzuki, K.2    Kato, S.3    Fujita, K.4    Nozaki, Y.5    Hosono, K.6
  • 23
    • 77949893641 scopus 로고    scopus 로고
    • Measurement of liver elasticity with acoustic radiation force impulse (ARFI) technology: An alternative noninvasive method for staging liver fibrosis in viral hepatitis
    • Goertz RS, Zopf Y, Jugl V, Heide R, Janson C, Strobel D, et al. Measurement of liver elasticity with acoustic radiation force impulse (ARFI) technology: an alternative noninvasive method for staging liver fibrosis in viral hepatitis. Ultraschall in Med 2010;31:151-5.
    • (2010) Ultraschall in Med , vol.31 , pp. 151-5
    • Goertz, R.S.1    Zopf, Y.2    Jugl, V.3    Heide, R.4    Janson, C.5    Strobel, D.6
  • 24
    • 77955466243 scopus 로고    scopus 로고
    • Acoustic radiation force impulse: A new ultrasonographic technology for the widespread noninvasive diagnosis of liver fibrosis
    • Boursier J, Isselin G, Fouchard-Hubert I, Oberti F, Dib N, Lebigot J, et al. Acoustic radiation force impulse: a new ultrasonographic technology for the widespread noninvasive diagnosis of liver fibrosis. Eur J Gastroenterol Hepatol 2010; 22:1074-84.
    • (2010) Eur J Gastroenterol Hepatol , vol.22 , pp. 1074-84
    • Boursier, J.1    Isselin, G.2    Fouchard-Hubert, I.3    Oberti, F.4    Dib, N.5    Lebigot, J.6
  • 27
    • 73349121651 scopus 로고    scopus 로고
    • Food intake increases liver stiffness in patients with chronic or resolved hepatitis C virus infection
    • Mederacke I, Wursthorn K, Kirschner J, Rifai K, Manns MP, Wedemeyer H, et al. Food intake increases liver stiffness in patients with chronic or resolved hepatitis C virus infection. Liver Int 2009;29:1500-6.
    • (2009) Liver Int , vol.29 , pp. 1500-6
    • Mederacke, I.1    Wursthorn, K.2    Kirschner, J.3    Rifai, K.4    Manns, M.P.5    Wedemeyer, H.6
  • 28
    • 77958547499 scopus 로고    scopus 로고
    • Acoustic radiation force impulse liver stiffness measurement: Interlobe differences demand standardized examination procedures
    • Karlas T, Pfrepper C, Troeltzsch M, Wiegand J, Keim V. Acoustic radiation force impulse liver stiffness measurement: interlobe differences demand standardized examination procedures. Eur J Gastroenterol 2010;22:1387.
    • (2010) Eur J Gastroenterol , vol.22 , pp. 1387
    • Karlas, T.1    Pfrepper, C.2    Troeltzsch, M.3    Wiegand, J.4    Keim, V.5
  • 31
    • 39549105171 scopus 로고    scopus 로고
    • Transient elastography is unreliable for detection of cirrhosis in patients with acute liver damage
    • DOI 10.1002/hep.22056
    • Sagir A, Erhardt A, Schmitt M, Häussinger D. Transient elastography is unreliable for detection of cirrhosis in patients with acute liver damage. Hepatology 2008;47: 592-5. (Pubitemid 351280727)
    • (2008) Hepatology , vol.47 , Issue.2 , pp. 592-595
    • Sagir, A.1    Erhardt, A.2    Schmitt, M.3    Haussinger, D.4
  • 32
    • 79953890315 scopus 로고    scopus 로고
    • Acoustic radiation force impulse (ARFI) elastography in acute liver failure: Necrosis mimics cirrhosis
    • Karlas T, Pfrepper C, Rosendahl J, Benckert C, Wittekind C, Jonas S, et al. Acoustic radiation force impulse (ARFI) elastography in acute liver failure: necrosis mimics cirrhosis. Z Gastroenterol 2011;49:443-8.
    • (2011) Z Gastroenterol , vol.49 , pp. 443-8
    • Karlas, T.1    Pfrepper, C.2    Rosendahl, J.3    Benckert, C.4    Wittekind, C.5    Jonas, S.6
  • 33
  • 34
    • 70349574440 scopus 로고    scopus 로고
    • Applicability and variability of liver stiffness measurements according to probe position
    • Ingiliz P, Chhay KP, Munteanu M, Lebray P, Ngo Y, Roulot D, et al. Applicability and variability of liver stiffness measurements according to probe position. World J Gastro-enterol 2009;15:3398-404.
    • (2009) World J Gastro-enterol , vol.15 , pp. 3398-404
    • Ingiliz, P.1    Chhay, K.P.2    Munteanu, M.3    Lebray, P.4    Ngo, Y.5    Roulot, D.6
  • 35
    • 79960444535 scopus 로고    scopus 로고
    • Evaluation of regional hepatic perfusion (RHP) by contrast-enhanced ultrasound in patients with cirrhosis
    • Berzigotti A, Nicolau C, Bellot P, Abraldes JG, Gilabert R, García-Pagan JC, et al. Evaluation of regional hepatic perfusion (RHP) by contrast-enhanced ultrasound in patients with cirrhosis. J Hepatol 2011;55:307-14.
    • (2011) J Hepatol , vol.55 , pp. 307-14
    • Berzigotti, A.1    Nicolau, C.2    Bellot, P.3    Abraldes, J.G.4    Gilabert, R.5    García-Pagan, J.C.6
  • 36
    • 14644444565 scopus 로고    scopus 로고
    • Fibrosis heterogeneity in nonalcoholic steatohepatitis and hepatitis C virus needle core biopsy specimens
    • DOI 10.1309/EY72-F1EN-9XCB-1KXX
    • Goldstein NS, Hastah F, Galan MV, Gordon SC. Fibrosis heterogeneity in nonalcoholic steatohepatitis and hepatitis C virus needle core biopsy specimens. Am J Clin Pathol 2005; 123:382-7. (Pubitemid 40315079)
    • (2005) American Journal of Clinical Pathology , vol.123 , Issue.3 , pp. 382-387
    • Goldstein, N.S.1    Hastah, F.2    Galan, M.V.3    Gordon, S.C.4
  • 37


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.