메뉴 건너뛰기




Volumn 16, Issue 11, 2011, Pages

High-resolution imaging diagnosis of human fetal membrane by three-dimensional optical coherence tomography

Author keywords

fetal membrane; high frequency ultrasound; microscopic chorionic pseudocyst; optical coherence tomography; preeclampsia

Indexed keywords

CLINICAL DETECTION; EX-VIVO; FEASIBILITY STUDIES; FETAL MEMBRANES; FOUR-LAYER ARCHITECTURE; HIGH FREQUENCY ULTRASOUNDS; HIGH-RESOLUTION IMAGING; IMAGING DEPTH; MEDICAL CONDITIONS; PREECLAMPSIA; PSEUDOCYST; THREE-DIMENSIONAL (3D);

EID: 80655125497     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.3646530     Document Type: Article
Times cited : (7)

References (14)
  • 2
    • 14644412849 scopus 로고    scopus 로고
    • Pre-eclampsia
    • DOI 10.1016/S0140-6736(05)17987-2
    • B. Sibai, G. Dekker, and M. Kupferminc, Pre-eclampsia., The Lancet 365, 785-799 (2005). 10.1016/S0140-6736(05)71003-5 (Pubitemid 40311367)
    • (2005) Lancet , vol.365 , Issue.9461 , pp. 785-799
    • Sibai, B.1    Dekker, G.2    Kupferminc, M.3
  • 3
    • 0020082393 scopus 로고
    • Syndrome of hemolysis, elevated liver enzymes, and low platelet count: A severe consequence of hypertension in pregnancy
    • L. Weinstein, Syndrome of hemolysis, elevated liver enzymes, and low platelet count: a severe consequence of hypertension in pregnancy., Obstet. Gynecol. Surv. 142, 159-167 (1982). 10.1097/00006254-198207000-00006 (Pubitemid 12222094)
    • (1982) American Journal of Obstetrics and Gynecology , vol.142 , Issue.2 , pp. 159-167
    • Weinstein, L.1
  • 4
    • 0037707889 scopus 로고    scopus 로고
    • Diagnosis and management of gestational hypertension and preeclampsia
    • DOI 10.1016/S0029-7844(03)00475-7
    • B. Sibai, Diagnosis and management of gestational hypertension and preeclampsia., Obstet. Gynecol. 102, 181-192 (2003). 10.1016/S0029-7844(03) 00475-7 (Pubitemid 36792143)
    • (2003) Obstetrics and Gynecology , vol.102 , Issue.1 , pp. 181-192
    • Sibai, B.M.1
  • 5
    • 0029995680 scopus 로고    scopus 로고
    • Heterogeneous causes constituting the single syndrome of preeclampsia: A hypothesis and its implications
    • R. Ness and J. Roberts, Heterogeneous causes constituting the single syndrome of preeclampsia: a hypothesis and its implications., Am. J. Obstet. Gynecol. 175, 1365-1370 (1996). 10.1016/S0002-9378(96)70056-X (Pubitemid 26399006)
    • (1996) American Journal of Obstetrics and Gynecology , vol.175 , Issue.5 , pp. 1365-1370
    • Ness, R.B.1    Roberts, J.M.2
  • 6
    • 34447624147 scopus 로고    scopus 로고
    • Microscopic chorionic pseudocysts in placental membranes: A histologic lesion of in utero hypoxia
    • DOI 10.2350/06-06-0110.1
    • J. Stanek and E. Weng, Microscopic chorionic pseudocysts in placental membranes: a histologic lesion of in utero hypoxia., Pediatr. Dev. Pathol. 10, 192-198 (2007). 10.2350/06-06-0110.1 (Pubitemid 350188037)
    • (2007) Pediatric and Developmental Pathology , vol.10 , Issue.3 , pp. 192-198
    • Stanek, J.1    Weng, E.2
  • 7
    • 77954335396 scopus 로고    scopus 로고
    • Diagnosing placental membrane hypoxic lesions increases the sensitivity of placental examination
    • 10.1043/2009-0280-OA.1
    • J. Stanek, Diagnosing placental membrane hypoxic lesions increases the sensitivity of placental examination., Arch. Pathol. Lab Med. 134, 989-995 (2010). 10.1043/2009-0280-OA.1
    • (2010) Arch. Pathol. Lab Med. , vol.134 , pp. 989-995
    • Stanek, J.1
  • 8
    • 61549090906 scopus 로고    scopus 로고
    • A digital frequency ramping method for enhancing Doppler flow imaging in Fourier-domain optical coherence tomography
    • 10.1364/OE.17.003951
    • Z. Yuan, Z. Luo, H. Ren, C. Du, and Y. Pan, A digital frequency ramping method for enhancing Doppler flow imaging in Fourier-domain optical coherence tomography., Opt. Express 17, 3951-3963 (2009). 10.1364/OE.17.003951
    • (2009) Opt. Express , vol.17 , pp. 3951-3963
    • Yuan, Z.1    Luo, Z.2    Ren, H.3    Du, C.4    Pan, Y.5
  • 9
    • 74049123619 scopus 로고    scopus 로고
    • On the possibility of time-lapse ultrahigh-resolution optical coherence tomography for bladder cancer grading
    • 10.1117/1.3223246
    • Z. Yuan, B. Chen, H. Ren, and Y. Pan, On the possibility of time-lapse ultrahigh-resolution optical coherence tomography for bladder cancer grading., J. Biomed. Opt. 1, 050502 (2009). 10.1117/1.3223246
    • (2009) J. Biomed. Opt. , vol.1 , pp. 050502
    • Yuan, Z.1    Chen, B.2    Ren, H.3    Pan, Y.4
  • 10
    • 70849135969 scopus 로고    scopus 로고
    • Diagnosis of bladder cancer with microelectromechanical systems-based cystoscopic optical coherence tomography
    • 10.1016/j.urology.2009.04.090
    • H. Ren, W. Waltzer, R. Bhalla, J. Liu, Z. Yuan, C. Lee, F. Darras, D. Schulsinger, H. Adler, and J. Kim, Diagnosis of bladder cancer with microelectromechanical systems-based cystoscopic optical coherence tomography., Urology 74, 1351-1357 (2009). 10.1016/j.urology.2009.04.090
    • (2009) Urology , vol.74 , pp. 1351-1357
    • Ren, H.1    Waltzer, W.2    Bhalla, R.3    Liu, J.4    Yuan, Z.5    Lee, C.6    Darras, F.7    Schulsinger, D.8    Adler, H.9    Kim, J.10
  • 11
    • 58449084092 scopus 로고    scopus 로고
    • Three-dimensional endomicroscopy of the human colon using optical coherence tomography
    • 10.1364/OE.17.000784
    • D. Adler, C. Zhou, T. Tsai, J. Schmitt, Q. Huang, H. Mashimo, and J. Fujimoto, Three-dimensional endomicroscopy of the human colon using optical coherence tomography., Opt. Express 17, 784-796 (2009). 10.1364/OE.17.000784
    • (2009) Opt. Express , vol.17 , pp. 784-796
    • Adler, D.1    Zhou, C.2    Tsai, T.3    Schmitt, J.4    Huang, Q.5    Mashimo, H.6    Fujimoto, J.7
  • 12
    • 80052985773 scopus 로고    scopus 로고
    • Enhancing detection of bladder carcinoma in situ by 3-dimensional optical coherence tomography
    • 10.1016/j.juro.2010.05.087
    • H. Ren, Z. Yuan, W. Waltzer, K. Shroyer, and Y. Pan, Enhancing detection of bladder carcinoma in situ by 3-dimensional optical coherence tomography., J. Urology 184, 1499-1506 (2010). 10.1016/j.juro.2010.05.087
    • (2010) J. Urology , vol.184 , pp. 1499-1506
    • Ren, H.1    Yuan, Z.2    Waltzer, W.3    Shroyer, K.4    Pan, Y.5
  • 13
    • 80655133121 scopus 로고    scopus 로고
    • In vivo cervical imaging with an integrated optical coherence tomography colposcope
    • T. Li, ed., Vol. 38 of OSA Trends in Optics and Photonics (Optical Society of America), paper SuC5
    • C. Pitris, P. Hsiung, X. Li, W. Drexler, J. G. Fujimoto, A. Goodman, and M. Brezinski, In vivo cervical imaging with an integrated optical coherence tomography colposcope, in Biomedical Optical Spectroscopy and Diagnostics, T. Li, ed., Vol. 38 of OSA Trends in Optics and Photonics (Optical Society of America, 2000), paper SuC5.
    • (2000) Biomedical Optical Spectroscopy and Diagnostics
    • Pitris, C.1    Hsiung, P.2    Li, X.3    Drexler, W.4    Fujimoto, J.G.5    Goodman, A.6    Brezinski, M.7
  • 14
    • 60849098770 scopus 로고    scopus 로고
    • High-resolution imaging diagnosis and staging of bladder cancer: Comparison between optical coherence tomography and high-frequency ultrasound
    • 10.1117/1.2978059
    • Z. Yuan, Z. Wang, R. Pan, J. Liu, H. Cohen, and Y. Pan, High-resolution imaging diagnosis and staging of bladder cancer: comparison between optical coherence tomography and high-frequency ultrasound., J. Biomed. Opt. 13, 054007 (2008). 10.1117/1.2978059
    • (2008) J. Biomed. Opt. , vol.13 , pp. 054007
    • Yuan, Z.1    Wang, Z.2    Pan, R.3    Liu, J.4    Cohen, H.5    Pan, Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.