메뉴 건너뛰기




Volumn 83, Issue 1, 2012, Pages 19-24

Sol-gel immobilized biosensor for the detection of organophosphorous pesticides: A voltammetric method

Author keywords

Acetylcholinesterase; Acetylthiocholine chloride; Carbon paste electrode; Immobilization; Methyl parathion and acephate

Indexed keywords

ACETYLCHOLINESTERASE; ACETYLTHIOCHOLINE CHLORIDE; AMPEROMETRIC BIOSENSORS; ANALYTICAL CHALLENGE; ANODIC PEAKS; CALOMEL ELECTRODES; CARBON PASTE ELECTRODE; CONCENTRATION RANGES; DETECTION LIMITS; ENZYME BIOSENSORS; ENZYME LOADING; INCUBATION TIME; INFLUENCE OF PH; METHYL PARATHION; OPERATIONAL STABILITY; OPTIMUM WORKING CONDITIONS; ORGANOPHOSPHOROUS COMPOUNDS; ORGANOPHOSPHOROUS PESTICIDES; PHOSPHATE BUFFERS; SILICA SOL GELS; SUBSTRATE CONCENTRATIONS; THIOCHOLINE; VOLTAMMETRIC;

EID: 80555150703     PISSN: 15675394     EISSN: 1878562X     Source Type: Journal    
DOI: 10.1016/j.bioelechem.2011.08.002     Document Type: Article
Times cited : (82)

References (29)
  • 1
    • 77952718897 scopus 로고    scopus 로고
    • Mono-enzyme biosensor for the detection of organophosphorous compounds
    • Tavakoli H., Ghourchian H. Mono-enzyme biosensor for the detection of organophosphorous compounds. J. Iran. Chem. Soc. 2010, 7:322-332.
    • (2010) J. Iran. Chem. Soc. , vol.7 , pp. 322-332
    • Tavakoli, H.1    Ghourchian, H.2
  • 2
    • 0001820835 scopus 로고    scopus 로고
    • New trends in biosensors for organophosphorus pesticides
    • Jaffrezic-Renault Nicole New trends in biosensors for organophosphorus pesticides. Sensors 2001, 1:60-74.
    • (2001) Sensors , vol.1 , pp. 60-74
    • Jaffrezic-Renault, N.1
  • 3
    • 33750368821 scopus 로고    scopus 로고
    • Detection of carbamic and organophosphorous pesticides in water samples using a cholinesterase biosensor based on Prussian Blue-modified screen-printed electrode
    • Arduini F., Ricci F., Tauta C.S., Moscone D., Amine A., Palleschi G. Detection of carbamic and organophosphorous pesticides in water samples using a cholinesterase biosensor based on Prussian Blue-modified screen-printed electrode. Anal. Chim. Acta 2006, 580:155-162.
    • (2006) Anal. Chim. Acta , vol.580 , pp. 155-162
    • Arduini, F.1    Ricci, F.2    Tauta, C.S.3    Moscone, D.4    Amine, A.5    Palleschi, G.6
  • 4
    • 34547555986 scopus 로고    scopus 로고
    • Acetylcholinesterase immobilization on 3-mercaptopropionic acid self assembled monolayer for determination of pesticides
    • Pedrosa Valber A., ca etano Josiame, Machado Sergio A.S., Freire Renato S., Bertotti Mauro Acetylcholinesterase immobilization on 3-mercaptopropionic acid self assembled monolayer for determination of pesticides. Electroanalysis 2007, 19:1415-1420.
    • (2007) Electroanalysis , vol.19 , pp. 1415-1420
    • Pedrosa, V.A.1    ca etano, J.2    Machado, S.A.S.3    Freire, R.S.4    Bertotti, M.5
  • 6
    • 0030960067 scopus 로고    scopus 로고
    • Sol-gel based amperometric biosensor incorporating an osmium redox polymer as mediator for detection of L-lactate
    • Park T.M., Lcouoha E.I., Smyth M.R., Freoney R., Mcshane A.J. Sol-gel based amperometric biosensor incorporating an osmium redox polymer as mediator for detection of L-lactate. Talanta 1997, 44:973-978.
    • (1997) Talanta , vol.44 , pp. 973-978
    • Park, T.M.1    Lcouoha, E.I.2    Smyth, M.R.3    Freoney, R.4    Mcshane, A.J.5
  • 7
    • 0031937009 scopus 로고    scopus 로고
    • Amperometric biosensor with a composite membrane of sol-gel derived enzyme film and electrochemically generated poly(1,2-diaminobenzene) film
    • Yao T., Takashima K. Amperometric biosensor with a composite membrane of sol-gel derived enzyme film and electrochemically generated poly(1,2-diaminobenzene) film. Biosens. Bioelectron. 1998, 13:67-73.
    • (1998) Biosens. Bioelectron. , vol.13 , pp. 67-73
    • Yao, T.1    Takashima, K.2
  • 8
    • 0035971840 scopus 로고    scopus 로고
    • A novel ferrocene encapsulated palladium-linked ormosil-based electrocatalytic dopamine biosensor
    • Pandey P.C., Upadhyay S., Tiwari I., Singh G., Tripathi V.S. A novel ferrocene encapsulated palladium-linked ormosil-based electrocatalytic dopamine biosensor. Sens. Actuators, B 2001, 75:48-55.
    • (2001) Sens. Actuators, B , vol.75 , pp. 48-55
    • Pandey, P.C.1    Upadhyay, S.2    Tiwari, I.3    Singh, G.4    Tripathi, V.S.5
  • 9
    • 0032971985 scopus 로고    scopus 로고
    • Amperometric determination of hydrogen peroxide by utilizing a sol-gel-derived biosensor incorporating an osmium redox polymer as mediator
    • Park T.M. Amperometric determination of hydrogen peroxide by utilizing a sol-gel-derived biosensor incorporating an osmium redox polymer as mediator. Anal. Lett. 1999, 32:287-298.
    • (1999) Anal. Lett. , vol.32 , pp. 287-298
    • Park, T.M.1
  • 10
    • 0032482207 scopus 로고    scopus 로고
    • Silica sol-gel immobilized amperometric biosensor for the determination of phenolic compounds
    • Li J., china L.S., Goh N.K., Tan S.N. Silica sol-gel immobilized amperometric biosensor for the determination of phenolic compounds. Anal. Chim. Acta 1998, 362:203-211.
    • (1998) Anal. Chim. Acta , vol.362 , pp. 203-211
    • Li, J.1    china, L.S.2    Goh, N.K.3    Tan, S.N.4
  • 11
    • 0035980505 scopus 로고    scopus 로고
    • Tetraphenylborate doped polyaniline based novel pH sensor and solid-state urea biosensor
    • Pandey P.C., Singh G. Tetraphenylborate doped polyaniline based novel pH sensor and solid-state urea biosensor. Talanta 2001, 55:773-782.
    • (2001) Talanta , vol.55 , pp. 773-782
    • Pandey, P.C.1    Singh, G.2
  • 12
    • 0031128409 scopus 로고    scopus 로고
    • Sol-gel glass as a matrix for chemical and biochemical sensing
    • Lin J., Brown C.W. Sol-gel glass as a matrix for chemical and biochemical sensing. Trends Anal. Chem. 1997, 16:200-211.
    • (1997) Trends Anal. Chem. , vol.16 , pp. 200-211
    • Lin, J.1    Brown, C.W.2
  • 13
    • 7444221122 scopus 로고    scopus 로고
    • Development of acetylcholinesterase silica sol-gel immobilized biosensor-an application towards oxydemeton methyl detection
    • Anitha K., VenkataMohan S., Jayarama Reddy S. Development of acetylcholinesterase silica sol-gel immobilized biosensor-an application towards oxydemeton methyl detection. Biosens. Bioelectron. 2004, 20:848-856.
    • (2004) Biosens. Bioelectron. , vol.20 , pp. 848-856
    • Anitha, K.1    VenkataMohan, S.2    Jayarama Reddy, S.3
  • 14
    • 0032834319 scopus 로고    scopus 로고
    • Evaluation of a highly sensitive amperometric biosensor with low cholinesterase charge immobilized on a chemically modified carbon paste electrode for trace determination of carbamates in fruit, vegetable and water samples
    • Nunes G.S., Barcelo D., Grabaric B.S., Diazcruz J.M., Ribeiro M.L. Evaluation of a highly sensitive amperometric biosensor with low cholinesterase charge immobilized on a chemically modified carbon paste electrode for trace determination of carbamates in fruit, vegetable and water samples. Anal. Chim. Acta 1999, 399:37-49.
    • (1999) Anal. Chim. Acta , vol.399 , pp. 37-49
    • Nunes, G.S.1    Barcelo, D.2    Grabaric, B.S.3    Diazcruz, J.M.4    Ribeiro, M.L.5
  • 15
    • 77956483682 scopus 로고    scopus 로고
    • Voltammetric resolution of dopamine in the presence of ascorbic acid and uric acid at poly (calmagite) film coated carbon paste electrode
    • Chandra Umesh, Kumara Swamy B.E., Gilbert Ongera, Sherigara B.S. Voltammetric resolution of dopamine in the presence of ascorbic acid and uric acid at poly (calmagite) film coated carbon paste electrode. Electrochem. Acta 2010, 55:7166-7174.
    • (2010) Electrochem. Acta , vol.55 , pp. 7166-7174
    • Chandra, U.1    Kumara Swamy, B.E.2    Gilbert, O.3    Sherigara, B.S.4
  • 16
    • 70350495373 scopus 로고    scopus 로고
    • Simultaneous detection of dopamine and ascorbic acid using polyglycine modified carbon paste electrode: a cyclic voltammetric study
    • Gilbert Ongera, Kumara Swamy B.E., Chandra Umesh, Sherigara B.S. Simultaneous detection of dopamine and ascorbic acid using polyglycine modified carbon paste electrode: a cyclic voltammetric study. J. Electroanal. Chem. 2009, 636:80-85.
    • (2009) J. Electroanal. Chem. , vol.636 , pp. 80-85
    • Gilbert, O.1    Kumara Swamy, B.E.2    Chandra, U.3    Sherigara, B.S.4
  • 17
    • 77955273581 scopus 로고    scopus 로고
    • Electrocatalytic oxidation of sodium levothyroxine with phenyl hydrazine as a mediator at carbon paste electrode: a cyclic voltammetric study
    • Chithravathi S., Kumara Swamy B.E., Cahndra Umesh, Mamatha G.P., Sherigara B.S. Electrocatalytic oxidation of sodium levothyroxine with phenyl hydrazine as a mediator at carbon paste electrode: a cyclic voltammetric study. J. Electroanal. Chem. 2010, 645:10-15.
    • (2010) J. Electroanal. Chem. , vol.645 , pp. 10-15
    • Chithravathi, S.1    Kumara Swamy, B.E.2    Cahndra, U.3    Mamatha, G.P.4    Sherigara, B.S.5
  • 18
    • 0028136099 scopus 로고
    • Karube Acetylcholinesterase in organic solvents for the detection of pesticides: biosensor application
    • Mionelto N., Marty J.-L., Karube Acetylcholinesterase in organic solvents for the detection of pesticides: biosensor application. Biosens. Bioelectron. 1994, 9:463-470.
    • (1994) Biosens. Bioelectron. , vol.9 , pp. 463-470
    • Mionelto, N.1    Marty, J.-L.2
  • 19
    • 0035980499 scopus 로고    scopus 로고
    • Evaluation of immobilized redox indicators as reversible, in situ redox sensors for determining Fe(III)-reducing conditions in environmental samples
    • Jones B.D., Ingle J.D. Evaluation of immobilized redox indicators as reversible, in situ redox sensors for determining Fe(III)-reducing conditions in environmental samples. Talanta 2001, 55:699-714.
    • (2001) Talanta , vol.55 , pp. 699-714
    • Jones, B.D.1    Ingle, J.D.2
  • 20
    • 33644595649 scopus 로고    scopus 로고
    • Preparation and electrocatalytic properties of the TBO/nafion chemically-modified electrodes
    • Shen M.C., Gheng H.C., Vasantha V.S. Preparation and electrocatalytic properties of the TBO/nafion chemically-modified electrodes. J. Electroanal. Chem. 2006, 588:235-243.
    • (2006) J. Electroanal. Chem. , vol.588 , pp. 235-243
    • Shen, M.C.1    Gheng, H.C.2    Vasantha, V.S.3
  • 21
    • 27144547838 scopus 로고    scopus 로고
    • Acetylcholinesterase sensor based on screen-printed carbon electrode modified with prussian blue
    • Suprun E., Evtugun G., Budnikov H., Ricci F., Moscone D., Palleschi G. Acetylcholinesterase sensor based on screen-printed carbon electrode modified with prussian blue. Anal. Bioanal. Chem. 2005, 383:597-604.
    • (2005) Anal. Bioanal. Chem. , vol.383 , pp. 597-604
    • Suprun, E.1    Evtugun, G.2    Budnikov, H.3    Ricci, F.4    Moscone, D.5    Palleschi, G.6
  • 22
    • 13444311894 scopus 로고    scopus 로고
    • Lowering the detection limit of the acetylcholinesterase biosensor using a nanoporous carbon matrix
    • Sotiropoulou S., Chaniotakis N.A. Lowering the detection limit of the acetylcholinesterase biosensor using a nanoporous carbon matrix. Anal. Chim. Acta. 2005, 530:199-204.
    • (2005) Anal. Chim. Acta. , vol.530 , pp. 199-204
    • Sotiropoulou, S.1    Chaniotakis, N.A.2
  • 23
    • 2342529173 scopus 로고    scopus 로고
    • Cholinesterase sensors based on screen-printed electrodes for detection of organophosphorus and carbamic pesticides
    • Ivanov A., Evtugyn G., Budnikov H., Riccif, Moscone D., Palleschi G. Cholinesterase sensors based on screen-printed electrodes for detection of organophosphorus and carbamic pesticides. Anal. Bioanal. Chem. 2003, 377:624-631.
    • (2003) Anal. Bioanal. Chem. , vol.377 , pp. 624-631
    • Ivanov, A.1    Evtugyn, G.2    Budnikov, H.3    Riccif4    Moscone, D.5    Palleschi, G.6
  • 24
    • 0031817907 scopus 로고    scopus 로고
    • Sensitivity and selectivity of electrochemical enzyme sensors for inhibitor determination
    • Evtugyn G.A., Budnikov H.C., Nikolskaya E.B. Sensitivity and selectivity of electrochemical enzyme sensors for inhibitor determination. Talanta 1998, 46:465-484.
    • (1998) Talanta , vol.46 , pp. 465-484
    • Evtugyn, G.A.1    Budnikov, H.C.2    Nikolskaya, E.B.3
  • 25
    • 42749093521 scopus 로고    scopus 로고
    • Development of a portable biosensor for screening neurotoxic agents in water samples
    • Hildebrandt Alian, Ribas Jordi, Bragos Ramon, Marty Jean - Louis, Tresanchez Marius, Lacorte Silvia Development of a portable biosensor for screening neurotoxic agents in water samples. Talanta 2008, 75:1208-1213.
    • (2008) Talanta , vol.75 , pp. 1208-1213
    • Hildebrandt, A.1    Ribas, J.2    Bragos, R.3    Marty, J.-L.4    Tresanchez, M.5    Lacorte, S.6
  • 26
    • 4644305182 scopus 로고    scopus 로고
    • Differential pulse adsorptive stripping voltammetric determination of nifedipine and nimodipine in pharmaceutical formulations, urine, and serum samples by using a clay-modified carbon-paste electrode
    • Madhusudana Reddy T., Reddy S.J. Differential pulse adsorptive stripping voltammetric determination of nifedipine and nimodipine in pharmaceutical formulations, urine, and serum samples by using a clay-modified carbon-paste electrode. Anal. Lett. 2004, 37:2079-2098.
    • (2004) Anal. Lett. , vol.37 , pp. 2079-2098
    • Madhusudana Reddy, T.1    Reddy, S.J.2
  • 27
    • 0037467211 scopus 로고    scopus 로고
    • Voltametric behavior of Cefixime and Cefpodoxime Proxetil and determination in pharmaceutical formulations and urine
    • Madhusudana Reddy T., Sreedhar M., Reddy S.J. Voltametric behavior of Cefixime and Cefpodoxime Proxetil and determination in pharmaceutical formulations and urine. J. Pharm. Biomed. Anal. 2003, 31:811-818.
    • (2003) J. Pharm. Biomed. Anal. , vol.31 , pp. 811-818
    • Madhusudana Reddy, T.1    Sreedhar, M.2    Reddy, S.J.3
  • 28
    • 23244443448 scopus 로고    scopus 로고
    • Electroanalytical method for determination of the pesticide dichlorvos using gold-disk microelectrodes
    • De Souza Djenaine, Machado Sergio A.S. Electroanalytical method for determination of the pesticide dichlorvos using gold-disk microelectrodes. Anal. Bioanal. Chem. 2005, 382:1720-1725.
    • (2005) Anal. Bioanal. Chem. , vol.382 , pp. 1720-1725
    • De Souza, D.1    Machado, S.A.S.2
  • 29
    • 70249119325 scopus 로고    scopus 로고
    • Electro-oxidation and determination of gabapentin at gold electrode
    • Hegde Rajesh.N., Kumara Swamy B.E., Shetti Nagaraj.P., Nandibewoor Sharanappa.T. Electro-oxidation and determination of gabapentin at gold electrode. J. Electroanal. Chem. 2009, 635:51-57.
    • (2009) J. Electroanal. Chem. , vol.635 , pp. 51-57
    • Hegde, R.1    Kumara Swamy, B.E.2    Shetti, N.3    Nandibewoor, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.