메뉴 건너뛰기




Volumn 21, Issue 2, 1997, Pages 121-130

Are intraaortic balloons suitable for reuse? A survey study of 112 used intraaortic balloons

Author keywords

intraaortic balloon; intraaortic balloon devices reuse; material properties; polyurethane

Indexed keywords

BALLOONS; CHEMICAL ANALYSIS; DEBRIS; DIFFERENTIAL SCANNING CALORIMETRY; FATIGUE TESTING; INSPECTION; MORPHOLOGY; STRAIN; SURFACE CHEMISTRY;

EID: 8044250878     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1525-1594.1997.tb00348.x     Document Type: Article
Times cited : (9)

References (28)
  • 2
    • 0016156362 scopus 로고
    • Intraaortic balloon counterpulsation: A review of physiological principles, clinical results, and device safety
    • Karl TW, Joseph SJ. Intraaortic balloon counterpulsation: A review of physiological principles, clinical results, and device safety. Ann Thorac Surg 1974; 17:602-36.
    • (1974) Ann Thorac Surg , vol.17 , pp. 602-636
    • Karl, T.W.1    Joseph, S.J.2
  • 3
    • 0026934782 scopus 로고
    • Intraaortic balloon rupture: An increasing trend?
    • Alvarez JM, Brady PW, McWilson R. Intraaortic balloon rupture: An increasing trend? ASAIO J 1992;38:862-3.
    • (1992) ASAIO J , vol.38 , pp. 862-863
    • Alvarez, J.M.1    Brady, P.W.2    McWilson, R.3
  • 5
    • 0028126732 scopus 로고
    • Reuse of balloon catheter for coronary angioplasty: A potential cost-saving strategy?
    • Sylvain P, Bradley HS, Gilles G, Randel KW, Robert JC. Reuse of balloon catheter for coronary angioplasty: A potential cost-saving strategy? J Am Coll Cardiol 1994;24:1475-81.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 1475-1481
    • Sylvain, P.1    Bradley, H.S.2    Gilles, G.3    Randel, K.W.4    Robert, J.C.5
  • 6
    • 0023685703 scopus 로고
    • The infection risk of cardiac catheterization and arterial angiography with single and multiple use disposable catheters
    • Frank U, Herz L, Daschner FD. The infection risk of cardiac catheterization and arterial angiography with single and multiple use disposable catheters. Clin Cardiol 1988;11:785-7.
    • (1988) Clin Cardiol , vol.11 , pp. 785-787
    • Frank, U.1    Herz, L.2    Daschner, F.D.3
  • 7
    • 0017336869 scopus 로고
    • Reuse of disposable catheters and guide wires
    • Ravin CE, Koehler PR. Reuse of disposable catheters and guide wires. Radiology 1977;122:577-9.
    • (1977) Radiology , vol.122 , pp. 577-579
    • Ravin, C.E.1    Koehler, P.R.2
  • 8
  • 9
    • 0022976882 scopus 로고
    • Reuse of disposable medical devices: Historical and current aspects
    • Greene VW. Reuse of disposable medical devices: Historical and current aspects. Infect Control 1986;7:508-13.
    • (1986) Infect Control , vol.7 , pp. 508-513
    • Greene, V.W.1
  • 10
    • 0025689380 scopus 로고
    • Effects of reuse on the physical characteristics of angiographic catheter
    • Bentolila P, Jacob R, Roberge F. Effects of reuse on the physical characteristics of angiographic catheter. J Med Eng Technol 1990;16:254-9.
    • (1990) J Med Eng Technol , vol.16 , pp. 254-259
    • Bentolila, P.1    Jacob, R.2    Roberge, F.3
  • 12
    • 8044239745 scopus 로고
    • Montreal, Quebec, Canada: CETS
    • Conseil d'évaluation des technologies de la santé du Québec (CETS). The reuse of single-use cardiac catheters. Montreal, Quebec, Canada: CETS, 1993.
    • (1993) The Reuse of Single-use Cardiac Catheters
  • 13
    • 0026602878 scopus 로고
    • Degradation of five polyurethane gastric bubbles following in vivo use: SEC, ATR-IR, and DSC studies
    • Dillon JG, Hughes MK. Degradation of five polyurethane gastric bubbles following in vivo use: SEC, ATR-IR, and DSC studies. Biomatrials 1992; 13:240-8.
    • (1992) Biomatrials , vol.13 , pp. 240-248
    • Dillon, J.G.1    Hughes, M.K.2
  • 15
    • 0017906135 scopus 로고
    • Infrared thermal analysis of polyurethane block polymers
    • Srichatrapimuk VW, Cooper SL. Infrared thermal analysis of polyurethane block polymers. J Macromol Sci Phys 1978;B15: 267-311.
    • (1978) J Macromol Sci Phys , vol.B15 , pp. 267-311
    • Srichatrapimuk, V.W.1    Cooper, S.L.2
  • 16
    • 70350772489 scopus 로고
    • Infrared spectra and structure of polyurethane elastomers from polytetrahydrofuran diphenylmethane-4,4′-diisocyanate and ethylenediamine
    • Nakayama K, Iro T, Matsuhara I. Infrared spectra and structure of polyurethane elastomers from polytetrahydrofuran diphenylmethane-4,4′-diisocyanate and ethylenediamine. J Macromol Sci Chem 1969;A3:1005-20.
    • (1969) J Macromol Sci Chem , vol.A3 , pp. 1005-1020
    • Nakayama, K.1    Iro, T.2    Matsuhara, I.3
  • 20
    • 0021723035 scopus 로고
    • Delayed abrasion perforation of two intra-aortic balloons
    • Mayerhofer KE, Billhardt RA, Codini MA. Delayed abrasion perforation of two intra-aortic balloons. Am Heart J 1984;108: 1361-3.
    • (1984) Am Heart J , vol.108 , pp. 1361-1363
    • Mayerhofer, K.E.1    Billhardt, R.A.2    Codini, M.A.3
  • 21
    • 0028819849 scopus 로고
    • Retained intraaortic balloon. Case report and review of the literature
    • Grande AM, Martinelli L, Graffigna A, Viganó M. Retained intraaortic balloon. Case report and review of the literature. Tex Heart Inst J 1995;22:332-4.
    • (1995) Tex Heart Inst J , vol.22 , pp. 332-334
    • Grande, A.M.1    Martinelli, L.2    Graffigna, A.3    Viganó, M.4
  • 24
    • 0023426264 scopus 로고
    • Percutaneous intraaortic balloon pumping: Four years from Tiblisi
    • Bregman D. Percutaneous intraaortic balloon pumping: Four years from Tiblisi. Artif Organs 1987;11:405-12.
    • (1987) Artif Organs , vol.11 , pp. 405-412
    • Bregman, D.1
  • 25
    • 0022242697 scopus 로고
    • Abrasion perforation of intra-aortic balloon
    • Kayser KL. Abrasion perforation of intra-aortic balloon. Am Heart J 1985;110:1311.
    • (1985) Am Heart J , vol.110 , pp. 1311
    • Kayser, K.L.1
  • 26
    • 0023062046 scopus 로고
    • Introduction of left ventricular assistance
    • Kantrowitz A. Introduction of left ventricular assistance. ASAIO J 1987;33:39-48.
    • (1987) ASAIO J , vol.33 , pp. 39-48
    • Kantrowitz, A.1
  • 27
    • 8044232050 scopus 로고
    • Cranbury, NJ: Roche Medical Electronics Division, AVCO
    • Intro-Aortic Balloon Pump Operators Manual, Cranbury, NJ: Roche Medical Electronics Division, AVCO, 1973.
    • (1973) Intro-Aortic Balloon Pump Operators Manual
  • 28
    • 0019738103 scopus 로고
    • Analyses of longest intra-aortic balloon implant in human patient (327 days)
    • Ashar B, Turcotte LR. Analyses of longest intra-aortic balloon implant in human patient (327 days). ASAIO J 1981;27: 372-9.
    • (1981) ASAIO J , vol.27 , pp. 372-379
    • Ashar, B.1    Turcotte, L.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.