메뉴 건너뛰기




Volumn 58, Issue 1, 2012, Pages 65-70

Model-based strategy for bioanalytical method comparison: Measurement of a soluble ligand as a biomarker

Author keywords

Biomarker method cross validation; LBAs; Method differences; Soluble ligand

Indexed keywords

ANTIBODY; BIOLOGICAL MARKER; GLYCOPROTEIN; LIGAND X; UNCLASSIFIED DRUG;

EID: 80255127448     PISSN: 07317085     EISSN: 1873264X     Source Type: Journal    
DOI: 10.1016/j.jpba.2011.09.004     Document Type: Article
Times cited : (4)

References (7)
  • 1
    • 64149124608 scopus 로고    scopus 로고
    • Method validation of protein biomarkers in support of drug development or clinical diagnosis/prognosis
    • Lee J.W., Hall M. Method validation of protein biomarkers in support of drug development or clinical diagnosis/prognosis. J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci. 2009, 877:1259-1271.
    • (2009) J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci. , vol.877 , pp. 1259-1271
    • Lee, J.W.1    Hall, M.2
  • 3
    • 68249144517 scopus 로고    scopus 로고
    • Fit-for-purpose method validation and application of a biomarker (C-terminal telopeptides of type 1 collagen) in Denosumab Clinical Studies
    • Wang J., Lee J., Burns D., Doherty D., Brunner L., Peterson M., DeSilva B. Fit-for-purpose method validation and application of a biomarker (C-terminal telopeptides of type 1 collagen) in Denosumab Clinical Studies. AAPS J. 2009, 11:385-394.
    • (2009) AAPS J. , vol.11 , pp. 385-394
    • Wang, J.1    Lee, J.2    Burns, D.3    Doherty, D.4    Brunner, L.5    Peterson, M.6    DeSilva, B.7
  • 4
    • 61449194154 scopus 로고    scopus 로고
    • Experimental and statistical approaches in method cross-validation to support pharmacokinetic decision
    • Thway T.M., Ma M., Lee J., Sloey B. Experimental and statistical approaches in method cross-validation to support pharmacokinetic decision. J. Pharm. Biomed. Anal. 2009, 49:613-618.
    • (2009) J. Pharm. Biomed. Anal. , vol.49 , pp. 613-618
    • Thway, T.M.1    Ma, M.2    Lee, J.3    Sloey, B.4
  • 5
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., Altman D.C. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 327:1307-1310.
    • (1986) Lancet , vol.327 , pp. 1307-1310
    • Bland, J.M.1    Altman, D.C.2
  • 6
    • 0038675123 scopus 로고    scopus 로고
    • Applying the right statistics: analyses of measurement studies
    • Bland J.M., Altman D.C. Applying the right statistics: analyses of measurement studies. Ultrasound Obstet. Gynecol. 2003, 22:85-93.
    • (2003) Ultrasound Obstet. Gynecol. , vol.22 , pp. 85-93
    • Bland, J.M.1    Altman, D.C.2
  • 7
    • 0015545686 scopus 로고
    • Use and interpretation of common statistical tests in method-comparison studies
    • Westgard J.O., Hunt M.R. Use and interpretation of common statistical tests in method-comparison studies. Clin. Chem. 1973, 19:49-57.
    • (1973) Clin. Chem. , vol.19 , pp. 49-57
    • Westgard, J.O.1    Hunt, M.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.