메뉴 건너뛰기




Volumn 14, Issue 3, 2011, Pages 203-218

Complication rate of molar crowns: A practice-based clinical evaluation;Komplikationsraten bei molarenkronen: Eine praxisbasierte kinische untersuchung

Author keywords

All ceramic; Chipping; Clinical trial; Crown; PFM restoration; Success rate; Veneering ceramic; Zirconia

Indexed keywords


EID: 80155207298     PISSN: 14634201     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (25)
  • 1
    • 76649086340 scopus 로고    scopus 로고
    • Clinical success of zirconia in dental applications
    • Ozkurt Z, Kazazoǧlu E. Clinical success of zirconia in dental applications. J Prosthodont 2010;19(1):64-68.
    • (2010) J Prosthodont , vol.19 , Issue.1 , pp. 64-68
    • Ozkurt, Z.1    Kazazoǧlu, E.2
  • 2
    • 78651262006 scopus 로고    scopus 로고
    • Clinical trials in zirconia: A systematic review
    • Al-Amleh B, Lyons K, Swain M. Clinical trials in zirconia: a systematic review. J Oral Rehabil 2010;37:641-652.
    • (2010) J Oral Rehabil , vol.37 , pp. 641-652
    • Al-Amleh, B.1    Lyons, K.2    Swain, M.3
  • 3
    • 77956529457 scopus 로고    scopus 로고
    • Survival probability of zirconia-based fixed dental prostheses up to 5 yr: A systematic review of the literature
    • Schley JS, Heussen N, Reich S, Fischer J, Haselhuhn K, Wolfart S. Survival probability of zirconia-based fixed dental prostheses up to 5 yr: a systematic review of the literature. Eur J Oral Sci 2010;118(5):443-450.
    • (2010) Eur J Oral Sci , vol.118 , Issue.5 , pp. 443-450
    • Schley, J.S.1    Heussen, N.2    Reich, S.3    Fischer, J.4    Haselhuhn, K.5    Wolfart, S.6
  • 4
    • 79952273419 scopus 로고    scopus 로고
    • Survival of zirconia-and metal-supported fixed dental prostheses: A systematic review
    • Heintze SD, Rousson V. Survival of zirconia-and metal-supported fixed dental prostheses: a systematic review. Int J Prosthodont 2010;23:493-502.
    • (2010) Int J Prosthodont , vol.23 , pp. 493-502
    • Heintze, S.D.1    Rousson, V.2
  • 5
    • 79952058391 scopus 로고    scopus 로고
    • The performance of zirconium dioxide crowns: A clinical follow-up
    • Groten M, Huttig F. The Performance of Zirconium Dioxide Crowns: A Clinical Follow-up. Int J Prosthodont 2010;23(5):429-431.
    • (2010) Int J Prosthodont , vol.23 , Issue.5 , pp. 429-431
    • Groten, M.1    Huttig, F.2
  • 6
    • 77952296078 scopus 로고    scopus 로고
    • Prospective evaluation of zirconia posterior fixed partial dentures: Four-year clinical results
    • Roediger M, Gersdorff N, Huels A, Rinke S. Prospective evaluation of zirconia posterior fixed partial dentures: four-year clinical results. Int J Prosthodont 2010;23(2):141-148.
    • (2010) Int J Prosthodont , vol.23 , Issue.2 , pp. 141-148
    • Roediger, M.1    Gersdorff, N.2    Huels, A.3    Rinke, S.4
  • 8
    • 59149106280 scopus 로고    scopus 로고
    • CAD/CAM zirconia vs. slipcast glass-infiltrated alumina/zirconia all-ceramic crowns: 2-year results of a randomized controlled clinical trial
    • Cehreli MC, Kökat AM, Akça K. CAD/CAM zirconia vs. slipcast glass-infiltrated alumina/zirconia all-ceramic crowns: 2-year results of a randomized controlled clinical trial. J Appl Oral Sci 2009;17(1):49-55.
    • (2009) J Appl Oral Sci , vol.17 , Issue.1 , pp. 49-55
    • Cehreli, M.C.1    Kökat, A.M.2    Akça, K.3
  • 10
    • 67650467257 scopus 로고    scopus 로고
    • A 3-year retrospective and clinical follow-up study of zirconia single crowns performed in a private practice
    • Ortorp A, Kihl ML, Carlsson GE. A 3-year retrospective and clinical follow-up study of zirconia single crowns performed in a private practice. J Dent 2009;37(9):731-736.
    • (2009) J Dent , vol.37 , Issue.9 , pp. 731-736
    • Ortorp, A.1    Kihl, M.L.2    Carlsson, G.E.3
  • 11
    • 34250612616 scopus 로고    scopus 로고
    • A systematic review of the survival and complication rates of allceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: Single crowns
    • Pjetursson BE, Sailer I, Zwahlen M, Hämmerle CH. A systematic review of the survival and complication rates of allceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: Single crowns. Clin Oral Implants Res 2007;18 Suppl 3:73-85.
    • (2007) Clin Oral Implants Res , vol.18 , Issue.3 SUPPL. , pp. 73-85
    • Pjetursson, B.E.1    Sailer, I.2    Zwahlen, M.3    Hämmerle, C.H.4
  • 12
    • 78650474280 scopus 로고    scopus 로고
    • Review. Erratum
    • Review. Erratum in: Clin Oral Implants Res 2008;19(3):326-328.
    • (2008) Clin Oral Implants Res , vol.19 , Issue.3 , pp. 326-328
  • 14
    • 0033223147 scopus 로고    scopus 로고
    • A 10-year longitudinal study of fixed prosthodontics: Clinical characteristics and outcome of single-unit metal-ceramic crowns
    • Walton TR: A 10-year longitudinal study of fixed prosthodontics: clinical characteristics and outcome of single-unit metal-ceramic crowns. Int J Prosthodont 1999;12:519-526.
    • (1999) Int J Prosthodont , vol.12 , pp. 519-526
    • Walton, T.R.1
  • 15
    • 78650487512 scopus 로고    scopus 로고
    • A clinical comparison of zirconia, metal and alumina fixed-prosthesis frameworks veneered with layered or pressed ceramic: A three year report
    • Christensen RP, Ploeger BJ. A Clinical Comparison of zirconia, Metal and Alumina Fixed-Prosthesis Frameworks Veneered with Layered or Pressed Ceramic: a Three Year Report. J Am Dent Assoc 2010;141:1317-1329.
    • (2010) J Am Dent Assoc , vol.141 , pp. 1317-1329
    • Christensen, R.P.1    Ploeger, B.J.2
  • 16
    • 77449113504 scopus 로고    scopus 로고
    • Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: A 3-year follow-up
    • Sailer I, Gottnerb J, Kanelb S, Hämmerle CH. Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up. Int J Prosthodont 2009;22(6):553-560.
    • (2009) Int J Prosthodont , vol.22 , Issue.6 , pp. 553-560
    • Sailer, I.1    Gottnerb, J.2    Kanelb, S.3    Hämmerle, C.H.4
  • 17
    • 48549103602 scopus 로고    scopus 로고
    • All-ceramic inlay-retained fixed partial dentures: Preliminary results from a clinical study
    • Ohlmann B, Rammelsberg P, Schmitter M, Schwarz S, Gabbert O. All-ceramic inlay-retained fixed partial dentures: preliminary results from a clinical study. J Dent 2008;36:692-696.
    • (2008) J Dent , vol.36 , pp. 692-696
    • Ohlmann, B.1    Rammelsberg, P.2    Schmitter, M.3    Schwarz, S.4    Gabbert, O.5
  • 19
    • 67349133480 scopus 로고    scopus 로고
    • Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures
    • Swain MV. Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures. Acta Biomater 2009;5:1668-1677.
    • (2009) Acta Biomater , vol.5 , pp. 1668-1677
    • Swain, M.V.1
  • 20
    • 65549131011 scopus 로고    scopus 로고
    • Viscoelastic finite element stress analysis of the thermal compatibility of dental bilayer ceramic systems
    • De Hoff PH, Anusavice KJ. Viscoelastic finite element stress analysis of the thermal compatibility of dental bilayer ceramic systems. Int J Prosthodont 2009;22:56-61.
    • (2009) Int J Prosthodont , vol.22 , pp. 56-61
    • De Hoff, P.H.1    Anusavice, K.J.2
  • 21
    • 80155156466 scopus 로고    scopus 로고
    • Optimization of residual stresses on all-ceramic fixed partial dentures using finite element analysis with viscoelastic material modelling
    • Eser A, Bezold A, Wiesner C, Vollmann M. Optimization of residual stresses on all-ceramic fixed partial dentures using finite element analysis with viscoelastic material modelling. 22nd European Conference on Biomaterials 2009.
    • 22nd European Conference on Biomaterials 2009
    • Eser, A.1    Bezold, A.2    Wiesner, C.3    Vollmann, M.4
  • 22
    • 78049302564 scopus 로고    scopus 로고
    • Effect of firing protocols on cohesive failure of all-ceramic crowns
    • Rues S, Kröger E, Müller D, Schmitter M. Effect of firing protocols on cohesive failure of all-ceramic crowns. J Dent 2010;38(12):987-994.
    • (2010) J Dent , vol.38 , Issue.12 , pp. 987-994
    • Rues, S.1    Kröger, E.2    Müller, D.3    Schmitter, M.4
  • 24
    • 43449084359 scopus 로고    scopus 로고
    • Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures
    • Wettstein F, Sailer I, Roos M, Hämmerle CH. Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 2008;116(3):272-279.
    • (2008) Eur J Oral Sci , vol.116 , Issue.3 , pp. 272-279
    • Wettstein, F.1    Sailer, I.2    Roos, M.3    Hämmerle, C.H.4
  • 25
    • 20444408006 scopus 로고    scopus 로고
    • In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents
    • DOI 10.1016/j.prosdent.2005.04.011, PII S0022391305002362
    • Ernst CP, Cohnen U, Stender E, Willershausen B. In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents. J Prosthet Dent 2005;93(6):551-558. (Pubitemid 40798345)
    • (2005) Journal of Prosthetic Dentistry , vol.93 , Issue.6 , pp. 551-558
    • Ernst, C.-P.1    Cohnen, U.2    Stender, E.3    Willershausen, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.