-
1
-
-
33749431344
-
-
Washington, D.C.: IOM, National Academies Press
-
Bailar, J.C., L.M. Brosseau, H.J. Cohen, et al.: Reusability of Facemasks During an Influenza Pandemic. Washington, D.C.: IOM, National Academies Press, 2006.
-
(2006)
Reusability of Facemasks during an Influenza Pandemic
-
-
Bailar, J.C.1
Brosseau, L.M.2
Cohen, H.J.3
-
2
-
-
62149104178
-
Effect of decontamination on the filtration efficiency of two filtering facepiece respirator models
-
Viscusi, D.J., W.P. King, and R.E. Shaffer: Effect of decontamination on the filtration efficiency of two filtering facepiece respirator models. J. Int. Soc. Respir. Prot. 24:93–107 (2007).
-
(2007)
J. Int. Soc. Respir. Prot
, vol.24
, pp. 93-107
-
-
Viscusi, D.J.1
King, W.P.2
Shaffer, R.E.3
-
3
-
-
72649104624
-
Evaluation of five decontamination methods for filtering facepiece respirators
-
Viscusi, D.J., M.S. Bergman, B.C. Eimer, et al.: Evaluation of five decontamination methods for filtering facepiece respirators. Ann. Occup. Hyg. 53(8):815–827 (2009).
-
(2009)
Ann. Occup. Hyg
, vol.53
, Issue.8
, pp. 815-827
-
-
Viscusi, D.J.1
Bergman, M.S.2
Eimer, B.C.3
-
4
-
-
78649764119
-
Evaluation of multiple (3-cycle) decontamination processing for filtering facepiece respirators
-
Bergman, M.S., D.J. Viscusi, B.K. Heimbuch, et al.: Evaluation of multiple (3-cycle) decontamination processing for filtering facepiece respirators. J. Eng. Fibers Fabrics. 5(4):33–41 (2010).
-
(2010)
J. Eng. Fibers Fabrics
, vol.5
, Issue.4
, pp. 33-41
-
-
Bergman, M.S.1
Viscusi, D.J.2
Heimbuch, B.K.3
-
5
-
-
77957012668
-
Analysis of residual chemicals on filtering facepiece respirators after decontamination
-
Salter, W.B., K. Kinney, W.H. Wallace, et al.: Analysis of residual chemicals on filtering facepiece respirators after decontamination. J. Occup. Environ. Hyg. 7:437–445 (2010).
-
(2010)
J. Occup. Environ. Hyg
, vol.7
, pp. 437-445
-
-
Salter, W.B.1
Kinney, K.2
Wallace, W.H.3
-
6
-
-
72949123047
-
Development of a test system to evaluate the effectiveness of decontamination procedures for respirator surfaces when challenged by viral droplets
-
Vo, E., S. Rengasamy, and R. Shaffer: Development of a test system to evaluate the effectiveness of decontamination procedures for respirator surfaces when challenged by viral droplets. J. Appl. Environ Microbiol. 75:7303–7309 (2009).
-
(2009)
J. Appl. Environ Microbiol
, vol.75
, pp. 7303-7309
-
-
Vo, E.1
Rengasamy, S.2
Shaffer, R.3
-
7
-
-
62149092888
-
Development of a test system to apply virus containing particles to air permeable materials for the evaluation of decontamination procedures for filtering facepiece respirators
-
Fisher, E., S. Rengasamy, D.J. Viscusi, et al.: Development of a test system to apply virus containing particles to air permeable materials for the evaluation of decontamination procedures for filtering facepiece respirators. J. Appl. Environ. Microbiol. 75(6):1500–1507 (2009).
-
(2009)
J. Appl. Environ. Microbiol
, vol.75
, Issue.6
, pp. 1500-1507
-
-
Fisher, E.1
Rengasamy, S.2
Viscusi, D.J.3
-
8
-
-
78650131068
-
A method to determine the available UV-C dose for the decontamination of filtering facepiece respirators
-
Fisher, E., and R. Shaffer: A method to determine the available UV-C dose for the decontamination of filtering facepiece respirators. J. Appl. Microbiol. 110:287–295 (2011).
-
(2011)
J. Appl. Microbiol
, vol.110
, pp. 287-295
-
-
Fisher, E.1
Shaffer, R.2
-
9
-
-
10644258726
-
Damage of office supplies, personal use items, and over-the-counter medical devices after sterilization by ethylene oxide gas, electronic beam, and gamma radiation
-
Lucas, A.D., K. Merritt, and V. Hitchens: Damage of office supplies, personal use items, and over-the-counter medical devices after sterilization by ethylene oxide gas, electronic beam, and gamma radiation. Biomed. Instrument. Technol. 38:476–484 (2004).
-
(2004)
Biomed. Instrument. Technol
, vol.38
, pp. 476-484
-
-
Lucas, A.D.1
Merritt, K.2
Hitchens, V.3
-
10
-
-
2942657692
-
Effects of chemical and biologicalwarfare remediation agents on the materials of museum objects. Appl
-
Solazzo, C., D. Erhardt, F. Marte, et al.: Effects of chemical and biologicalwarfare remediation agents on the materials of museum objects. Appl. Physics A (79):247–252 (2004).
-
(2004)
Physics a (79)
, pp. 247-252
-
-
Solazzo, C.1
Erhardt, D.2
Marte, F.3
-
11
-
-
0035501398
-
Does UV irradiation affect polymer properties relevant to tissue engineering?
-
Fischbach, C., J. Tessmar, A. Lucke, et al.: Does UV irradiation affect polymer properties relevant to tissue engineering? Surface Sci. 491(3):333–345 (2001).
-
(2001)
Surface Sci
, vol.491
, Issue.3
, pp. 333-345
-
-
Fischbach, C.1
Tessmar, J.2
Lucke, A.3
-
12
-
-
0028271550
-
Variation in quantitative respirator fit factors due to fluctuations in leak size during fit testing
-
Krishnan, U., K. Willeke, A. Jouzaitis, et al.: Variation in quantitative respirator fit factors due to fluctuations in leak size during fit testing. Am. Hyg. J. Ind. 55:309–314 (1994).
-
(1994)
Am. Hyg. J. Ind
, vol.55
, pp. 309-314
-
-
Krishnan, U.1
Willeke, K.2
Jouzaitis, A.3
-
13
-
-
85011160600
-
-
Inc.: Model 8095 N-95-Companion to the PORTACOUNT Plus, Operation and Service Manual P/N 1980308, Revision H. St. Paul, Minn.: TSI, 2005
-
TSI, Inc.: Model 8095 N-95-Companion to the PORTACOUNT Plus, Operation and Service Manual P/N 1980308, Revision H. St. Paul, Minn.: TSI, 2005.
-
-
-
-
14
-
-
85011218663
-
-
Code of Federal Regulations Title 29, Part 1910.134 App. A. 1998
-
“Fit Testing Procedures (Mandatory),” Code of Federal Regulations Title 29, Part 1910.134 App. A. 1998.
-
-
-
-
15
-
-
23444443387
-
Reducing respirator fit test errors: Amulti-donning approach
-
Campbell, D.L., C.C. Coffey, P.A. Jensen, et al.: Reducing respirator fit test errors: amulti-donning approach. J. Occup. Environ. Hyg. 2:391–399. (2005).
-
(2005)
J. Occup. Environ. Hyg
, vol.2
, pp. 391-399
-
-
Campbell, D.L.1
Coffey, C.C.2
Jensen, P.A.3
-
16
-
-
0034786102
-
A modified protocol for quantitative fit testing using the Porta Count
-
Sreenath, A., J. Weed, and T. Church: A modified protocol for quantitative fit testing using the Porta Count. Appl. Occup. Environ. Hyg. 16:979–988. (2001).
-
(2001)
Appl. Occup. Environ. Hyg
, vol.16
, pp. 979-988
-
-
Sreenath, A.1
Weed, J.2
Church, T.3
-
17
-
-
70350782349
-
Issues in combining the categorical and visual analog scale for the assessment of perceived thermal sensation: Methodological and conceptual considerations. Appl
-
Lee, J., E.A. Stone, H. Wakabayashi, et al.: Issues in combining the categorical and visual analog scale for the assessment of perceived thermal sensation: Methodological and conceptual considerations. Appl. Ergon. 41:282–290. (2010).
-
(2010)
Ergon
, vol.41
, pp. 282-290
-
-
Lee, J.1
Stone, E.A.2
Wakabayashi, H.3
-
18
-
-
85011153781
-
-
“National Strategy for Pandemic Influenza. [Online] Available at http://www.whitehouse.gov/homeland/pandemic-influenza.html (Accessed November 28, 2010).
-
-
-
-
19
-
-
79551533152
-
Apandemic influenza preparedness study: Use of energetic methods to decontaminate filtering facepiece respirators contaminated with H1N1 aerosols and droplets
-
Heimbuch, B.K., W.H. Wallace, K. Kinney, et al.: Apandemic influenza preparedness study: Use of energetic methods to decontaminate filtering facepiece respirators contaminated with H1N1 aerosols and droplets. Am. J. Infect. Control. 39(1):e1–9 (2011).
-
(2011)
Am. J. Infect. Control
, vol.39
, Issue.1
, pp. e1-e9
-
-
Heimbuch, B.K.1
Wallace, W.H.2
Kinney, K.3
-
21
-
-
42949121713
-
Surgical mask filter and fit performance
-
Oberg, T., and L.M. Brosseau: Surgical mask filter and fit performance. Am. J. Infect. Control. 36:276–282 (2008).
-
(2008)
Am. J. Infect. Control
, vol.36
, pp. 276-282
-
-
Oberg, T.1
Brosseau, L.M.2
-
22
-
-
74449084898
-
Health care workers’ views about respirator use and features that should be included in the next generation of respirators
-
Baig, A.S., C. Knapp, A.E. Egan, et al.: Health care workers’ views about respirator use and features that should be included in the next generation of respirators. Am. J. Infect. Control. 38:18–25(2010).
-
(2010)
Am. J. Infect. Control
, vol.1825
, pp. 38
-
-
Baig, A.S.1
Knapp, C.2
Egan, A.E.3
-
23
-
-
77950253215
-
Physiological impact of the N95 filtering facepiece respirator on healthcare workers
-
Roberge, R., A. Coca, J.W. Williams, et al.: Physiological impact of the N95 filtering facepiece respirator on healthcare workers. Respir. Care. 55(5):569–577 (2010).
-
(2010)
Respir. Care
, vol.55
, Issue.5
, pp. 569-577
-
-
Roberge, R.1
Coca, A.2
Williams, J.W.3
|