1
-
-
0346260992
-
-
Technical Report No. TR A5540, SINTEF Energy Department, Norway, December
-
L. E. Lundgaard, W. Hansen, D. Linhjell, and T. J. Painter, "Ageing and Restoration of the Transformer Winding,"Technical Report No. TR A5540, SINTEF Energy Department, Norway, December 2001.
-
(2001)
Ageing and Restoration of the Transformer Winding
-
-
Lundgaard, L.E.1
Hansen, W.2
Linhjell, D.3
Painter, T.J.4
-
3
-
-
0346076735
-
Ageing of oil-impregnated paper in power transformers
-
January
-
L. E. Lundgaard, W. Hansen, D. Linhjell, and T. J. Painter, "Ageing of Oil-Impregnated Paper in Power Transformers", IEEE Transactions on Power Delivery, Vol. 19, No. 1, January 2004, pp. 230-239
-
(2004)
IEEE Transactions on Power Delivery
, vol.19
, Issue.1
, pp. 230-239
-
-
Lundgaard, L.E.1
Hansen, W.2
Linhjell, D.3
Painter, T.J.4
-
4
-
-
80155144443
-
-
Cigre SC A2&D1, Colloquium, No. 34, Brugges, Belgium October 7-12
-
L.E. Lundgaard, O. Lillevik, and K.B. Liland, "Verification of Paper Condition in aged Transformers", Cigre SC A2&D1, Colloquium, No. 34, Brugges, Belgium October 7-12, 2007
-
(2007)
Verification of Paper Condition in Aged Transformers
-
-
Lundgaard, L.E.1
Lillevik, O.2
Liland, K.B.3
-
5
-
-
0032777156
-
Moisture equilibrium transformer paper-oil system
-
Jan./Feb.
-
Y. Du, M. Zahn, B.C. Lesieutre, A.V Mamishev, and S.R. Lindgren, "Moisture Equilibrium Transformer Paper-Oil System," Electrical Insulation Magazine, IEEE, Vol. 15, No. 1, Jan./Feb. 1999, pp. 11-20
-
(1999)
Electrical Insulation Magazine, IEEE
, vol.15
, Issue.1
, pp. 11-20
-
-
Du, Y.1
Zahn, M.2
Lesieutre, B.C.3
Mamishev, A.V.4
Lindgren, S.R.5
-
7
-
-
42149154837
-
Ageing of mineral oil impregnated cellulose by acid catalysis
-
April
-
L. E. Lundgaard, W. Hansen and S. Ingebrigtsen, "Ageing of Mineral Oil impregnated Cellulose by Acid Catalysis," IEEE Transactions on Dielectrics and Electrical Insulation Vol. 15, No. 2; April 2008, pp. 540-546
-
(2008)
IEEE Transactions on Dielectrics and Electrical Insulation
, vol.15
, Issue.2
, pp. 540-546
-
-
Lundgaard, L.E.1
Hansen, W.2
Ingebrigtsen, S.3
-
9
-
-
77954197563
-
Moisture equlibrium curves - Use and misuse
-
April
-
T.V. Oommen, "Moisture Equlibrium Curves - Use and Misuse", Doble Conference Paper, April 2003
-
(2003)
Doble Conference Paper
-
-
Oommen, T.V.1
-
10
-
-
70349185535
-
-
PhD thesis, Institute of Energy Transmission and High Voltage Engineering, University of Stuttgart, Sierke Verlag Göttingen, Germany
-
M. Koch, "Reliable Moisture Determination in Power Transformers", PhD thesis, Institute of Energy Transmission and High Voltage Engineering, University of Stuttgart, Sierke Verlag Göttingen, Germany, 2008
-
(2008)
Reliable Moisture Determination in Power Transformers
-
-
Koch, M.1
-
11
-
-
80155172996
-
Some investigations on the variation of dielectric response during artificial ageing process if impregnated pressboard
-
ISH, Ljubljana, Slovenija
-
A.A. Shayegani, H. Mohseni, K. Niayesh, H. Borsi and E. Gockenbach, " Some Investigations on the Variation of Dielectric Response during Artificial Ageing Process if Impregnated Pressboard", Proceedings of XVth International Symposium on High Voltage Engineering, ISH, Ljubljana, Slovenija, 2007
-
(2007)
Proceedings of XVth International Symposium on High Voltage Engineering
-
-
Shayegani, A.A.1
Mohseni, H.2
Niayesh, K.3
Borsi, H.4
Gockenbach, E.5
-
12
-
-
2342599104
-
Hornification-its origin and interpretation in wood pulps
-
March
-
J.M.B. Fernades Diniz, M.H. Gil, J.A.A.M. Castro, "Hornification-its origin and interpretation in wood pulps", Wood Sci, Technology 37, March 2004, pp 489-494
-
(2004)
Wood Sci, Technology
, vol.37
, pp. 489-494
-
-
Fernades Diniz, J.M.B.1
Gil, M.H.2
Castro, J.A.A.M.3
-
13
-
-
78651466353
-
A practical method for the continous monitoring of water content in transformer solid insulation
-
New Orleans
-
B. Noirhomme, B. Sparling, J. Aubin, and P. Gervais, " A Practical Method for the Continous Monitoring of Water Content in Transformer Solid Insulation", Proceedings of EPRI Substation Equipment Diagnostics Conference VIII, New Orleans, 2000, p.201-214
-
(2000)
Proceedings of EPRI Substation Equipment Diagnostics Conference VIII
, pp. 201-214
-
-
Noirhomme, B.1
Sparling, B.2
Aubin, J.3
Gervais, P.4
-
14
-
-
80155211574
-
Determination of moisture in transformer insulation from long duration measurment of moisture in oil
-
Brugges, Belgium October 7-12
-
J. Aubin, H. Vogel, G. Bennett and J. Eitzel, "Determination of Moisture in Transformer Insulation from Long Duration Measurment of Moisture in Oil", Cigre SC A2&D1, Colloquium, No. 27, Brugges, Belgium October 7-12, 2007
-
(2007)
Cigre SC A2&D1, Colloquium, No. 27
-
-
Aubin, J.1
Vogel, H.2
Bennett, G.3
Eitzel, J.4
-
15
-
-
47349109306
-
Water absorption of cellulosic insulating materials used in power transformers
-
Winchester, UK, July 8-13
-
H.P. Gasser, C. Krause, and T. Prevost, "Water Absorption of Cellulosic Insulating Materials used in Power Transformers", 2007 International Conference on Solid Dielectrics, Winchester, UK, July 8-13, 2007
-
(2007)
2007 International Conference on Solid Dielectrics
-
-
Gasser, H.P.1
Krause, C.2
Prevost, T.3
-
16
-
-
80155175035
-
Temperature-dependent contamination distribution between oil, paper and pressboard
-
Paper submitted to, Trondheim Norway, June
-
D.Linhjell, L.E.Lundgaard, C.M.Selsbak, "Temperature-dependent Contamination Distribution between Oil, Paper and Pressboard", Paper submitted to IEEE Internationl Conference on Dielectric Liquides, Trondheim Norway, June, 2011
-
(2011)
IEEE Internationl Conference on Dielectric Liquides
-
-
Linhjell, D.1
Lundgaard, L.E.2
Selsbak, C.M.3
|