메뉴 건너뛰기




Volumn 20, Issue 11, 2011, Pages

Design of an adaptive control for a magnetorheological fluid brake with model parameters depending on temperature and speed

Author keywords

[No Author keywords available]

Indexed keywords

ADAPTIVE APPROACH; ADAPTIVE CONTROL; ADAPTIVE CONTROLLERS; DEVICE MODELS; FLUID VISCOSITY; MAGNETO-RHEOLOGICAL FLUID; MODEL PARAMETERS; SYSTEM MODELS; TIME CONSTANTS; TRACKING ERRORS;

EID: 80155189567     PISSN: 09641726     EISSN: 1361665X     Source Type: Journal    
DOI: 10.1088/0964-1726/20/11/115003     Document Type: Article
Times cited : (40)

References (28)
  • 2
    • 1142303840 scopus 로고    scopus 로고
    • Magnetorheological suspension electromagnetic brake
    • Bica I 2004 Magnetorheological suspension electromagnetic brake J. Magn. Mater. 270 321-6
    • (2004) J. Magn. Mater. , vol.270 , pp. 321-326
    • Bica, I.1
  • 6
    • 0030264561 scopus 로고    scopus 로고
    • Modeling and control of magnetorheological dampers for seismic response reduction
    • Dyke S J, Spencer B F Jr, Sain M K and Carlson J D 1996 Modeling and control of magnetorheological dampers for seismic response reduction Smart Mater. Struct. 5 565-75 (Pubitemid 126649193)
    • (1996) Smart Materials and Structures , vol.5 , Issue.5 , pp. 565-575
    • Dyke, S.J.1    Spencer Jr., B.F.2    Sain, M.K.3    Carlson, J.D.4
  • 8
    • 0002273510 scopus 로고    scopus 로고
    • A controllable squeeze film damper using magnetorheological fluid
    • (Bremen)
    • Jolly M R and Carlson J D 1996 A controllable squeeze film damper using magnetorheological fluid Proc. Actuator 96 (Bremen) pp333-6
    • (1996) Proc. Actuator 96 , pp. 333-336
    • Jolly, M.R.1    Carlson, J.D.2
  • 9
    • 33646365874 scopus 로고    scopus 로고
    • Application of some semi-active control algorithms to a smart base-isolated building employing MR dampers
    • Jung H J, Choi K M, Spencer B F Jr and Lee I W 2005 Application of some semi-active control algorithms to a smart base-isolated building employing MR dampers Struct. Control Health Monit. 13 693-704
    • (2005) Struct. Control Health Monit. , vol.13 , pp. 693-704
    • Jung, H.J.1    Choi, K.M.2    Spencer, B.F.3    Lee, I.W.4
  • 10
    • 0005050540 scopus 로고    scopus 로고
    • Analysis and testing of a model-scale magnetorheological fluid helicopter lag mode damper
    • Kamath G M, Wereley N M and Jolly M R 1996 Analysis and testing of a model-scale magnetorheological fluid helicopter lag mode damper J. Am. Helicopter Soc. 443 234-48
    • (1996) J. Am. Helicopter Soc. , vol.443 , pp. 234-248
    • Kamath, G.M.1    Wereley, N.M.2    Jolly, M.R.3
  • 11
    • 49849089368 scopus 로고    scopus 로고
    • Design considerations for an automotive magnetorheological brake
    • Karakoc K, Park E J and Suleman A 2008 Design considerations for an automotive magnetorheological brake Mechatronics 18 434-47
    • (2008) Mechatronics , vol.18 , pp. 434-447
    • Karakoc, K.1    Park, E.J.2    Suleman, A.3
  • 13
    • 0242467989 scopus 로고    scopus 로고
    • A multi-plate magneto-rheological fluid limited slip differential clutch Smart Structures and Materials
    • Kavlicoglu B, Gordaninejad F, Evrensel C, Fuchs A and Korol G 2003 A multi-plate magneto-rheological fluid limited slip differential clutch Smart Structures and Materials 2003 Proc. SPIE 5054 341-9
    • (2003) Proc. SPIE , vol.5054 , pp. 341-349
    • Kavlicoglu, B.1    Gordaninejad, F.2    Evrensel, C.3    Fuchs, A.4    Korol, G.5
  • 15
    • 33947634585 scopus 로고    scopus 로고
    • Response time and performance of a high-torque magneto-rheological fluid limited slip differential clutch
    • DOI 10.1088/0964-1726/16/1/019, PII S0964172607329571, 019
    • Kavlicoglu B, Kavlicoglu N, Liu Y, Evrensel C, Fuchs A, Korol G and Gordaninejad F 2007 Response time and performance of a high-torque magneto-rheological fluid limited slip differential clutch Smart Mater. Struct. 16 149-59 (Pubitemid 46485427)
    • (2007) Smart Materials and Structures , vol.16 , Issue.1 , pp. 149-159
    • Kavlicoglu, N.C.1    Kavlicoglu, B.M.2    Liu, Y.3    Evrensel, C.A.4    Fuchs, A.5    Korol, G.6    Gordaninejad, F.7
  • 17
    • 0037505917 scopus 로고    scopus 로고
    • MRF-Clutch-Design Considerations and Performance
    • Dresden University of Technology Dresden Germany, (Bremen)
    • Lampe D, Thess A and Dotzauer C 1998 Dresden University of Technology Dresden Germany MRF-Clutch-Design Considerations and Performance 6th Int. Conf. on New Actuators (Actuator 1998) (Bremen)
    • (1998) 6th Int. Conf. on New Actuators (Actuator 1998)
    • Lampe, D.1    Thess, A.2    Dotzauer, C.3
  • 18
    • 0038722759 scopus 로고    scopus 로고
    • Design and experimental evaluation of a magnetorheological brake
    • Li W H and Du H 2003 Design and experimental evaluation of a magnetorheological brake Int. J. Adv. Manuf. Technol. 21 508-15
    • (2003) Int. J. Adv. Manuf. Technol. , vol.21 , pp. 508-515
    • Li, W.H.1    Du, H.2
  • 19
    • 25444448551 scopus 로고    scopus 로고
    • Modeling and reduction of centrifuging in magnetorheological (MR) transmission clutches for automotive applications
    • DOI 10.1177/1045389X05054329
    • Neelakantan V A and Washington G N 2005 Modeling and reduction in centrifuging in magnetorheological (MR) transmission clutches for automotive applications J. Intell. Mater. Syst. Struct. 16 703-11 (Pubitemid 41374946)
    • (2005) Journal of Intelligent Material Systems and Structures , vol.16 , Issue.9 , pp. 703-711
    • Neelakantan, V.A.1    Washington, G.N.2
  • 20
    • 84908206007 scopus 로고
    • The magnetic fluid clutch
    • Rabinow J 1948 The magnetic fluid clutch AIEE Trans. 67 1308-15
    • (1948) AIEE Trans. , vol.67 , pp. 1308-1315
    • Rabinow, J.1
  • 21
    • 80055018762 scopus 로고    scopus 로고
    • Modelling, parameter identification and control of a shear mode magnetorheological device
    • Russo R and Terzo M 2011 Modelling, parameter identification and control of a shear mode magnetorheological device J. Syst. Control Eng. 225 549-62
    • (2011) J. Syst. Control Eng. , vol.225 , pp. 549-562
    • Russo, R.1    Terzo, M.2
  • 25
    • 0032179454 scopus 로고    scopus 로고
    • Nondimensional analysis of semi-active electrorheological and magnetorheological dampers using approximate parallel plate models
    • PII S0964172698962164
    • Wereley N M and Pang L 1998 Nondimensional analysis of semi-active electrorheological and magnetorheological dampers using approximate parallel plates models Smart Mater. Struct. 7 732-43 (Pubitemid 128625181)
    • (1998) Smart Materials and Structures , vol.7 , Issue.5 , pp. 732-743
    • Wereley, N.M.1    Pang, L.2
  • 26
    • 0037332083 scopus 로고    scopus 로고
    • Semi-active control of structures incorporated with magnetorheological dampers using neural-networks
    • Xu Z D, Shen Y P and Guo Y Q 2003 Semi-active control of structures incorporated with magnetorheological dampers using neural-networks Smart Mater. Struct. 12 80-7
    • (2003) Smart Mater. Struct. , vol.12 , pp. 80-87
    • Xu, Z.D.1    Shen, Y.P.2    Guo, Y.Q.3
  • 27
    • 31144458942 scopus 로고    scopus 로고
    • (University of Notre Dame)
    • Yang G 2001 Large-scale magnetorheological fluid damper for vibration mitigation: modeling testing and control PhD Dissertation (University of Notre Dame)
    • (2001) PhD Dissertation
    • Yang, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.