메뉴 건너뛰기




Volumn 21, Issue 6, 2011, Pages 616-622

Cardiac computed tomography and conventional angiography in the diagnosis of congenital cardiac disease in children: Recent trends and radiation doses

Author keywords

dual source computed tomography; imaging; Paediatric cardiology

Indexed keywords

ADOLESCENT; AGE; ARTICLE; BODY WEIGHT; CARDIAC DUAL SOURCE COMPUTER ASSISTED TOMOGRAPHY; CHILD; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CONGENITAL HEART DISEASE; CONTROLLED STUDY; CONVENTIONAL ANGIOGRAPHY; FEMALE; FLUOROSCOPY; HUMAN; INFANT; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PREVALENCE; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; RETROSPECTIVE STUDY; TREND STUDY;

EID: 80155136131     PISSN: 10479511     EISSN: 14671107     Source Type: Journal    
DOI: 10.1017/S1047951111000485     Document Type: Article
Times cited : (28)

References (27)
  • 1
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • Brenner D, Hall E. Computed tomography-an increasing source of radiation exposure. N Engl J Med 2007; 357: 2277-2284. (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 3
    • 33644857761 scopus 로고    scopus 로고
    • Temporal trends in the utilization of diagnostic testing and treatments for cardiovascular disease in the United States, 1993-2001
    • DOI 10.1161/CIRCULATIONAHA.105.560433, PII 0000301720060124000009
    • Lucas F, DeLorenzo M, Siewers A, Wennberg D. Temporal trends in the utilization of diagnostic testing and treatments for cardiovascular disease in the United States, 1993-2001. Circulation 2006; 113: 374-379. (Pubitemid 43803198)
    • (2006) Circulation , vol.113 , Issue.3 , pp. 374-379
    • Lucas, F.L.1    DeLorenzo, M.A.2    Siewers, A.E.3    Wennberg, D.E.4
  • 4
    • 33644871999 scopus 로고    scopus 로고
    • Rising rates of cardiac procedures in the United States and Canada: Too much of a good thing?
    • DOI 10.1161/CIRCULATIONAHA.105.598789, PII 0000301720060124000003
    • Ayanian J. Rising rates of cardiac procedures in the United States and Canada: too much of a good thing?. Circulation 2006; 113: 333-335. (Pubitemid 43803192)
    • (2006) Circulation , vol.113 , Issue.3 , pp. 333-335
    • Ayanian, J.Z.1
  • 5
    • 26044446462 scopus 로고    scopus 로고
    • Pediatric catheter interventions: A year in review 2004-2005
    • DOI 10.1097/01.mop.0000172813.56766.52
    • Patel H, Hijazi Z. Pediatric catheter interventions: a year in review 2004-2005. Curr Opin Pediatr 2005; 17: 568-573. (Pubitemid 41406116)
    • (2005) Current Opinion in Pediatrics , vol.17 , Issue.5 , pp. 568-573
    • Patel, H.T.1    Hijazi, Z.M.2
  • 6
    • 80155154920 scopus 로고    scopus 로고
    • Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation; Nuclear and Radiation Studies Board, Division on Earth and Life Studies, National Research Council of the National Academies. Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2. The National Academies Press, Washington, 2006
    • Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation; Nuclear and Radiation Studies Board, Division on Earth and Life Studies, National Research Council of the National Academies. Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2. The National Academies Press, Washington, 2006.
  • 7
    • 34247391986 scopus 로고    scopus 로고
    • Dose reduction in paediatric MDCT: General principles
    • DOI 10.1016/j.crad.2006.12.004, PII S0009926007000141
    • Paterson A, Frush D. Dose reduction in paediatric MDCT: general principles. Clin Radiol 2007; 62: 507-517. (Pubitemid 46630119)
    • (2007) Clinical Radiology , vol.62 , Issue.6 , pp. 507-517
    • Paterson, A.1    Frush, D.P.2
  • 8
    • 0036942687 scopus 로고    scopus 로고
    • Lessons we have learned from our children: Cancer risk from diagnostic radiology
    • DOI 10.1007/s00247-002-0774-8
    • Hall E. Lessons we have learned from our children: cancer risks from diagnostic radiology. Pediatr Radiol 2002; 32: 700-706. (Pubitemid 36067723)
    • (2002) Pediatric Radiology , vol.32 , Issue.10 , pp. 700-706
    • Hall, E.J.1
  • 9
    • 27744498721 scopus 로고    scopus 로고
    • CT dose reduction in children
    • DOI 10.1007/s00330-005-2856-0
    • Vock P. CT dose reduction in children. Eur Radiol 2005; 15: 2330-2340. (Pubitemid 41600119)
    • (2005) European Radiology , vol.15 , Issue.11 , pp. 2330-2340
    • Vock, P.1
  • 10
    • 40949104442 scopus 로고    scopus 로고
    • The 2007 recommendations of ICRP (ICRP publication 103)
    • International Commission on Radiological Protection (ICRP).
    • International Commission on Radiological Protection (ICRP). The 2007 recommendations of ICRP (ICRP publication 103). Ann ICRP 2007; 37: 1-332.
    • (2007) Ann ICRP , vol.37 , pp. 1-332
  • 11
    • 34548810410 scopus 로고    scopus 로고
    • The ALARA (as low as reasonably achievable) concept in pediatric interventional and fluoroscopic imaging: Striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients - A white paper executive summary
    • DOI 10.1007/s00247-006-0184-4
    • Strauss K, Kaste S. The ALARA (as low as reasonably achievable) concept in pediatric interventional and fluoroscopic imaging: striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients - a white paper executive summary. Pediatr Radiol 2006; 36(Suppl 2): 110-112. (Pubitemid 351601470)
    • (2006) Pediatric Radiology , vol.36 , Issue.SUPPL. 2 , pp. 110-112
    • Strauss, K.J.1    Kaste, S.C.2
  • 12
    • 34249850849 scopus 로고    scopus 로고
    • Pre- and postoperative evaluation of congenital heart disease in children and adults with 64-section CT
    • Leschka S, Oechslin E, Husmann L, et al. Pre- and postoperative evaluation of congenital heart disease in children and adults with 64-section CT. Radiographics 2007; 27: 829-846.
    • (2007) Radiographics , vol.27 , pp. 829-846
    • Leschka, S.1    Oechslin, E.2    Husmann, L.3
  • 13
    • 28044458289 scopus 로고    scopus 로고
    • Three-dimensional computed tomographic imaging of complex congenital cardiovascular abnormalities
    • DOI 10.1097/01.rct.0000181725.07716.f4
    • Bean M, Pannu H, Fishman E. Three-dimensional computed tomographic imaging of complex congenital cardiovascular abnormalities. J Comput Assist Tomogr 2005; 29: 721-724. (Pubitemid 41689529)
    • (2005) Journal of Computer Assisted Tomography , vol.29 , Issue.6 , pp. 721-724
    • Bean, M.J.1    Pannu, H.2    Fishman, E.K.3
  • 14
    • 2142696558 scopus 로고    scopus 로고
    • Diagnostic CT scans: Assessment of patient, physician, and radiologist awareness of radiation dose and possible risks
    • DOI 10.1148/radiol.2312030767
    • Lee C, Haims A, Monico E, Brink J, Forman H. Diagnostic CT scans: assessment of patient, physician, and radiologist awareness of radiation dose and possible risks. Radiology 2004; 231: 393-398. (Pubitemid 38552895)
    • (2004) Radiology , vol.231 , Issue.2 , pp. 393-398
    • Lee, C.I.1    Haims, A.H.2    Monico, E.P.3    Brink, J.A.4    Forman, H.P.5
  • 15
    • 76049129406 scopus 로고    scopus 로고
    • State-of-the-art CT imaging techniques for congenital heart disease
    • Goo H. State-of-the-art CT imaging techniques for congenital heart disease. Korean J Radiol 2010; 11: 4-18.
    • (2010) Korean J Radiol , vol.11 , pp. 4-18
    • Goo, H.1
  • 16
    • 0037448795 scopus 로고    scopus 로고
    • Radiation dose in computed tomography of the heart
    • DOI 10.1161/01.CIR.0000048965.56529.C2
    • Morin R, Gerber T, McCollough C. Radiation dose in computed tomography of the heart. Circulation 2003; 107: 917-922. (Pubitemid 36241053)
    • (2003) Circulation , vol.107 , Issue.6 , pp. 917-922
    • Morin, R.L.1    Gerber, T.C.2    McCollough, C.H.3
  • 17
    • 77649151324 scopus 로고    scopus 로고
    • Cumulative patient effective dose and acute radiation-induced chromosomal DNA damage in children with congenital heart disease
    • Ait-Ali L, Andreassi M, Foffa I, Spadoni I, Vano E, Picano E. Cumulative patient effective dose and acute radiation-induced chromosomal DNA damage in children with congenital heart disease. Heart 2010; 96: 269-274.
    • (2010) Heart , vol.96 , pp. 269-274
    • Ait-Ali, L.1    Andreassi, M.2    Foffa, I.3    Spadoni, I.4    Vano, E.5    Picano, E.6
  • 21
    • 69149083246 scopus 로고    scopus 로고
    • Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease
    • Ben Saad M, Rohnean A, Sigal-Cinqualbre A, Adler G, Paul J. Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease. Pediatr Radiol 2009; 39: 668-676.
    • (2009) Pediatr Radiol , vol.39 , pp. 668-676
    • Ben Saad, M.1    Rohnean, A.2    Sigal-Cinqualbre, A.3    Adler, G.4    Paul, J.5
  • 22
    • 65649131960 scopus 로고    scopus 로고
    • Role of CT in the evaluation of congenital cardiovascular disease in children
    • Dillman J, Hernandez R. Role of CT in the evaluation of congenital cardiovascular disease in children. AJR Am J Roentgenol 2009; 192: 1219-1231.
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 1219-1231
    • Dillman, J.1    Hernandez, R.2
  • 23
    • 77957867019 scopus 로고    scopus 로고
    • Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: First experience
    • Cheng Z, Wang X, Duan Y, et al. Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience. Eur Radiol 2010; 20: 2503-2511.
    • (2010) Eur Radiol , vol.20 , pp. 2503-2511
    • Cheng, Z.1    Wang, X.2    Duan, Y.3
  • 24
    • 63649084581 scopus 로고    scopus 로고
    • Strategies for doseoptimized imaging in pediatric cardiac dual source CT
    • Kuettner A, Gehann B, Spolnik J, et al. Strategies for doseoptimized imaging in pediatric cardiac dual source CT. Rofo 2009; 181: 339-348.
    • (2009) Rofo , vol.181 , pp. 339-348
    • Kuettner, A.1    Gehann, B.2    Spolnik, J.3
  • 25
    • 11244304718 scopus 로고    scopus 로고
    • Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization
    • DOI 10.1161/01.CIR.0000151098.52656.3A
    • Bacher K, Bogaert E, Lapere R, De Wolf D, Thierens H. Patientspecific dose and radiation risk estimation in pediatric cardiac catheterization. Circulation 2005; 111: 83-89. (Pubitemid 40070848)
    • (2005) Circulation , vol.111 , Issue.1 , pp. 83-89
    • Bacher, K.1    Bogaert, E.2    Lapere, R.3    De Wolf, D.4    Thierens, H.5
  • 27
    • 55249117729 scopus 로고    scopus 로고
    • Radiation dose survey in a paediatric cardiac catheterisation laboratory equipped with flat-panel detectors
    • Dragusin O, Gewillig M, Desmet W, Smans K, Struelens L, Bosmans H. Radiation dose survey in a paediatric cardiac catheterisation laboratory equipped with flat-panel detectors. Radiat Prot Dosimetry 2008; 129: 91-95.
    • (2008) Radiat Prot Dosimetry , vol.129 , pp. 91-95
    • Dragusin, O.1    Gewillig, M.2    Desmet, W.3    Smans, K.4    Struelens, L.5    Bosmans, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.